Opened 3 years ago

Last modified 3 years ago

#7899 feedback defect

FW: Hanging on PDB file

Reported by: kristen.browne@… Owned by: pett
Priority: normal Milestone:
Component: Structure Editing Version:
Keywords: Cc: Elaine Meng, phil.cruz@…
Blocked By: Blocking:
Notify when closed: Platform: all
Project: ChimeraX

Description

Sorry sent this to the admin by accident!

This is another workflow that is repeatedly hanging.

I'm not 100% as to what it is doing when the hang starts (but you do have my email address!)

K

Kristen Browne, MSc, MscBMC
Contractor - MSC, Inc. | A Guidehouse Company
3D Modeling and Biovisualization Specialist
Bioinformatics and Computational Biosciences Branch (BCBB)<https://www.niaid.nih.gov/research/bioinformatics-computational-biosciences-branch>
OCICB/OSMO/OD/NIAID/NIH

5601 Fishers Lane, Room 4A60
Rockville, MD 20852
Office 202-253-5228


1fvm-monomer-blue.pdb

logs (8).txt

Attachments (2)

1fvm-monomer-blue.pdb (48.1 KB ) - added by kristen.browne@… 3 years ago.
Added by email2trac
logs (8).txt (7.5 KB ) - added by kristen.browne@… 3 years ago.
Added by email2trac

Download all attachments as: .zip

Change History (4)

by kristen.browne@…, 3 years ago

Attachment: 1fvm-monomer-blue.pdb added

Added by email2trac

by kristen.browne@…, 3 years ago

Attachment: logs (8).txt added

Added by email2trac

comment:1 by pett, 3 years ago

Component: UnassignedStructure Editing
Owner: set to pett
Platform: all
Project: ChimeraX
Status: newaccepted

comment:2 by pett, 3 years ago

Cc: Elaine Meng phil.cruz@… added
Status: acceptedfeedback

Hi Kristen,

The problem here is that the semi-empirical sqm program that ChimeraX uses to determine partial charges in non-standard parts of structures can take a very long time for some moieties, particularly larger ones like this, with the fact that it forms a large ring possibly a contributing factor. It can also fail for some moieties, notably ones with significant negative charge concentrations (e.g. multiple phosphates).
I've been running coulombic/sqm on this entry for over 26 CPU hours, so who know if it would ever finish. There is an alternative charging method, "gasteiger", which is less accurate than sqm but which always finishes within a few seconds -- but which has its own set of (different) failure modes. Let me know if you want me to change the preset to that method.

--Eric

Note: See TracTickets for help on using tickets.