Opened 3 years ago

Closed 3 years ago

#6844 closed defect (fixed)

Flip peptide bond: wrapped C/C++ object of type QTableWidget has been deleted

Reported by: shuman@… Owned by: Tristan Croll
Priority: normal Milestone:
Component: Third Party Version:
Keywords: Cc:
Blocked By: Blocking:
Notify when closed: Platform: all
Project: ChimeraX

Description (last modified by Eric Pettersen)

The following bug report has been submitted:
Platform:        macOS-10.14.6-x86_64-i386-64bit
ChimeraX Version: 1.2.5 (2021-05-24 04:13:57 UTC)
Description
(Describe the actions that caused this problem to occur here)

Trying to flip a peptide bond with ISOLDE


Log:
UCSF ChimeraX version: 1.2.5 (2021-05-24)  
© 2016-2021 Regents of the University of California. All rights reserved.  
How to cite UCSF ChimeraX  

> open
> /Users/henryshuman/Documents/NAMD/myo1c_into_P19_J544/actomyo_2_myos_5actins_end_of_step4.pdb

Chain information for actomyo_2_myos_5actins_end_of_step4.pdb #1  
---  
Chain | Description  
A B C D E | No description available  
F | No description available  
L Q | No description available  
M N O R S T | No description available  
  

> ui tool show ISOLDE

> set selectionWidth 4

Chain information for actomyo_2_myos_5actins_end_of_step4.pdb  
---  
Chain | Description  
1.2/A 1.2/B 1.2/C 1.2/D 1.2/E | No description available  
1.2/F | No description available  
1.2/L 1.2/Q | No description available  
1.2/M 1.2/N 1.2/O 1.2/R 1.2/S 1.2/T | No description available  
  
Done loading forcefield  

> close #1.2

Deleting atomic symmetry model...  
Deleting atomic symmetry model...  
Traceback (most recent call last):  
File
"/Applications/ChimeraX-1.2.5.app/Contents/Library/Frameworks/Python.framework/Versions/3.8/lib/python3.8/site-
packages/chimerax/core/triggerset.py", line 130, in invoke  
return self._func(self._name, data)  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/validation/ramaplot.py", line 112, in
_selection_changed_cb  
residues = self.current_model.residues  
File
"/Applications/ChimeraX-1.2.5.app/Contents/Library/Frameworks/Python.framework/Versions/3.8/lib/python3.8/site-
packages/chimerax/core/attributes.py", line 61, in _getattr_  
return base.__getattr__(self, attr_name, look_in_class=base)  
File
"/Applications/ChimeraX-1.2.5.app/Contents/Library/Frameworks/Python.framework/Versions/3.8/lib/python3.8/site-
packages/chimerax/core/attributes.py", line 57, in _getattr_  
return look_in_class._attr_registration.get_attr(attr_name)  
File
"/Applications/ChimeraX-1.2.5.app/Contents/Library/Frameworks/Python.framework/Versions/3.8/lib/python3.8/site-
packages/chimerax/core/attributes.py", line 83, in get_attr  
raise AttributeError("Execution of '%s' object's '%s' property raised
AttributeError" % (self.class_.__name__, attr_name)) from None  
AttributeError: Execution of 'Structure' object's 'residues' property raised
AttributeError  
  
Error processing trigger "selection changed":  
AttributeError: Execution of 'Structure' object's 'residues' property raised
AttributeError  
  
File
"/Applications/ChimeraX-1.2.5.app/Contents/Library/Frameworks/Python.framework/Versions/3.8/lib/python3.8/site-
packages/chimerax/core/attributes.py", line 83, in get_attr  
raise AttributeError("Execution of '%s' object's '%s' property raised
AttributeError" % (self.class_.__name__, attr_name)) from None  
  
See log for complete Python traceback.  
  
'NoneType' object has no attribute 'triggers'  

> open
> /Users/henryshuman/Documents/NAMD/myo1c_into_P19_J544/actomyo_2_myos_5actins_step5.pdb

Summary of feedback from opening
/Users/henryshuman/Documents/NAMD/myo1c_into_P19_J544/actomyo_2_myos_5actins_step5.pdb  
---  
warnings | Ignored bad PDB record found on line 100001  
ATOM 186a0 OH2 TIP3W1770 -23.145 25.107 -15.159 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100002  
ATOM 186a1 H1 TIP3W1770 -22.383 25.594 -14.845 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100003  
ATOM 186a2 H2 TIP3W1770 -22.784 24.288 -15.498 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100004  
ATOM 186a3 OH2 TIP3W1771 68.800 -65.078 -14.015 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100005  
ATOM 186a4 H1 TIP3W1771 69.487 -64.970 -14.673 0.00 0.00 WT2  
  
91 messages similar to the above omitted  
Duplicate atom serial number found: 18700  
Duplicate atom serial number found: 18701  
Duplicate atom serial number found: 18702  
Duplicate atom serial number found: 18703  
Duplicate atom serial number found: 18704  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 100107  
ATOM 1870a H1 TIP3W1805 162.407 -20.939 -19.510 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100108  
ATOM 1870b H2 TIP3W1805 161.694 -21.206 -20.819 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100109  
ATOM 1870c OH2 TIP3W1806 -37.816 -9.491 -15.960 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100110  
ATOM 1870d H1 TIP3W1806 -38.562 -8.967 -16.253 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100111  
ATOM 1870e H2 TIP3W1806 -38.178 -10.365 -15.816 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 18710  
Duplicate atom serial number found: 18711  
Duplicate atom serial number found: 18712  
Duplicate atom serial number found: 18713  
Duplicate atom serial number found: 18714  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 100123  
ATOM 1871a H2 TIP3W1811 -2.527 194.040 21.296 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100124  
ATOM 1871b OH2 TIP3W1812 -68.000 -19.508 12.645 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100125  
ATOM 1871c H1 TIP3W1812 -67.515 -19.239 11.865 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100126  
ATOM 1871d H2 TIP3W1812 -68.079 -18.709 13.166 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100127  
ATOM 1871e OH2 TIP3W1813 -11.457 -35.501 -58.918 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 18720  
Duplicate atom serial number found: 18721  
Duplicate atom serial number found: 18722  
Duplicate atom serial number found: 18723  
Duplicate atom serial number found: 18724  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 100139  
ATOM 1872a OH2 TIP3W1817 -57.920 208.591 -32.188 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100140  
ATOM 1872b H1 TIP3W1817 -58.060 209.046 -31.357 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100141  
ATOM 1872c H2 TIP3W1817 -57.980 207.662 -31.966 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100142  
ATOM 1872d OH2 TIP3W1818 159.185 -40.185 14.307 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100143  
ATOM 1872e H1 TIP3W1818 158.634 -39.583 13.806 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 18730  
Duplicate atom serial number found: 18731  
Duplicate atom serial number found: 18732  
Duplicate atom serial number found: 18733  
Duplicate atom serial number found: 18734  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 100155  
ATOM 1873a H1 TIP3W1823 -59.481 -3.310 85.508 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100156  
ATOM 1873b H2 TIP3W1823 -60.975 -3.085 85.413 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100157  
ATOM 1873c OH2 TIP3W1824 6.388 -58.922 9.697 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100158  
ATOM 1873d H1 TIP3W1824 7.121 -59.505 9.894 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100159  
ATOM 1873e H2 TIP3W1824 5.948 -58.798 10.538 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 18740  
Duplicate atom serial number found: 18741  
Duplicate atom serial number found: 18742  
Duplicate atom serial number found: 18743  
Duplicate atom serial number found: 18744  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 100171  
ATOM 1874a H2 TIP3W1828 -61.419 201.471 -39.787 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100172  
ATOM 1874b OH2 TIP3W1829 -23.542 183.261 -21.971 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100173  
ATOM 1874c H1 TIP3W1829 -23.555 184.107 -21.523 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100174  
ATOM 1874d H2 TIP3W1829 -22.744 183.282 -22.499 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100175  
ATOM 1874e OH2 TIP3W1830 9.722 183.894 -95.220 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 18750  
Duplicate atom serial number found: 18751  
Duplicate atom serial number found: 18752  
Duplicate atom serial number found: 18753  
Duplicate atom serial number found: 18754  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 100187  
ATOM 1875a OH2 TIP3W1834 -56.686 43.167 -15.128 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100188  
ATOM 1875b H1 TIP3W1834 -56.055 43.806 -15.458 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100189  
ATOM 1875c H2 TIP3W1834 -56.472 43.075 -14.200 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100190  
ATOM 1875d OH2 TIP3W1835 -24.478 -69.843 -73.717 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100191  
ATOM 1875e H1 TIP3W1835 -23.907 -69.363 -74.317 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 18760  
Duplicate atom serial number found: 18761  
Duplicate atom serial number found: 18762  
Duplicate atom serial number found: 18763  
Duplicate atom serial number found: 18764  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 100203  
ATOM 1876a H1 TIP3W1839 -35.219 210.902 63.823 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100204  
ATOM 1876b H2 TIP3W1839 -35.882 210.172 62.675 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100205  
ATOM 1876c OH2 TIP3W1840 144.830 -56.470 -9.722 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100206  
ATOM 1876d H1 TIP3W1840 144.712 -56.079 -8.856 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100207  
ATOM 1876e H2 TIP3W1840 145.079 -57.377 -9.544 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 18770  
Duplicate atom serial number found: 18771  
Duplicate atom serial number found: 18772  
Duplicate atom serial number found: 18773  
Duplicate atom serial number found: 18774  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 100219  
ATOM 1877a H2 TIP3W1844 175.176 187.124 8.983 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100220  
ATOM 1877b OH2 TIP3W1846 157.793 -53.252 44.480 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100221  
ATOM 1877c H1 TIP3W1846 157.264 -52.528 44.142 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100222  
ATOM 1877d H2 TIP3W1846 158.307 -53.545 43.727 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100223  
ATOM 1877e OH2 TIP3W1847 98.792 -67.456 -88.063 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 18780  
Duplicate atom serial number found: 18781  
Duplicate atom serial number found: 18782  
Duplicate atom serial number found: 18783  
Duplicate atom serial number found: 18784  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 100235  
ATOM 1878a OH2 TIP3W1852 135.205 -36.461 -66.872 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100236  
ATOM 1878b H1 TIP3W1852 136.052 -36.641 -66.466 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100237  
ATOM 1878c H2 TIP3W1852 135.299 -36.772 -67.772 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100238  
ATOM 1878d OH2 TIP3W1853 -7.419 -62.665 -34.801 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100239  
ATOM 1878e H1 TIP3W1853 -7.173 -61.795 -35.115 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 18790  
Duplicate atom serial number found: 18791  
Duplicate atom serial number found: 18792  
Duplicate atom serial number found: 18793  
Duplicate atom serial number found: 18794  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 100251  
ATOM 1879a H1 TIP3W1857 10.833 205.287 -9.337 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100252  
ATOM 1879b H2 TIP3W1857 9.781 205.078 -8.268 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100253  
ATOM 1879c OH2 TIP3W1858 -46.420 -58.396 80.710 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100254  
ATOM 1879d H1 TIP3W1858 -45.624 -58.828 80.401 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100255  
ATOM 1879e H2 TIP3W1858 -46.860 -59.057 81.244 0.00 0.00 WT2  
  
97 messages similar to the above omitted  
Duplicate atom serial number found: 18800  
Duplicate atom serial number found: 18801  
Duplicate atom serial number found: 18802  
Duplicate atom serial number found: 18803  
Duplicate atom serial number found: 18804  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 100363  
ATOM 1880a H2 TIP3W1894 165.394 -50.744 -30.683 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100364  
ATOM 1880b OH2 TIP3W1895 -13.196 3.964 -22.110 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100365  
ATOM 1880c H1 TIP3W1895 -12.441 3.843 -22.685 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100366  
ATOM 1880d H2 TIP3W1895 -13.867 3.383 -22.469 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100367  
ATOM 1880e OH2 TIP3W1896 -22.231 -61.374 -15.150 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 18810  
Duplicate atom serial number found: 18811  
Duplicate atom serial number found: 18812  
Duplicate atom serial number found: 18813  
Duplicate atom serial number found: 18814  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 100379  
ATOM 1881a OH2 TIP3W1900 -58.408 -21.854 -3.051 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100380  
ATOM 1881b H1 TIP3W1900 -58.900 -21.091 -2.749 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100381  
ATOM 1881c H2 TIP3W1900 -57.736 -21.493 -3.630 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100382  
ATOM 1881d OH2 TIP3W1901 -38.877 -24.047 34.606 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100383  
ATOM 1881e H1 TIP3W1901 -37.941 -24.178 34.759 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 18820  
Duplicate atom serial number found: 18821  
Duplicate atom serial number found: 18822  
Duplicate atom serial number found: 18823  
Duplicate atom serial number found: 18824  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 100395  
ATOM 1882a H1 TIP3W1905 152.693 203.754 -1.395 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100396  
ATOM 1882b H2 TIP3W1905 152.316 205.200 -1.153 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100397  
ATOM 1882c OH2 TIP3W1906 -29.730 -36.042 -62.917 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100398  
ATOM 1882d H1 TIP3W1906 -29.203 -36.589 -63.500 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100399  
ATOM 1882e H2 TIP3W1906 -29.771 -36.535 -62.097 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 18830  
Duplicate atom serial number found: 18831  
Duplicate atom serial number found: 18832  
Duplicate atom serial number found: 18833  
Duplicate atom serial number found: 18834  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 100411  
ATOM 1883a H2 TIP3W1910 156.609 -5.686 33.549 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100412  
ATOM 1883b OH2 TIP3W1911 160.053 209.626 -55.095 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100413  
ATOM 1883c H1 TIP3W1911 160.509 208.807 -55.292 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100414  
ATOM 1883d H2 TIP3W1911 159.221 209.556 -55.563 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100415  
ATOM 1883e OH2 TIP3W1912 -42.270 -68.325 30.633 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 18840  
Duplicate atom serial number found: 18841  
Duplicate atom serial number found: 18842  
Duplicate atom serial number found: 18843  
Duplicate atom serial number found: 18844  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 100427  
ATOM 1884a OH2 TIP3W1916 131.151 -31.094 31.948 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100428  
ATOM 1884b H1 TIP3W1916 130.500 -31.795 31.940 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100429  
ATOM 1884c H2 TIP3W1916 131.425 -31.010 31.034 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100430  
ATOM 1884d OH2 TIP3W1917 -56.517 -24.214 -8.725 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100431  
ATOM 1884e H1 TIP3W1917 -57.355 -23.913 -8.374 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 18850  
Duplicate atom serial number found: 18851  
Duplicate atom serial number found: 18852  
Duplicate atom serial number found: 18853  
Duplicate atom serial number found: 18854  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 100443  
ATOM 1885a H1 TIP3W1921 -47.485 -32.228 -6.105 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100444  
ATOM 1885b H2 TIP3W1921 -46.969 -31.408 -7.268 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100445  
ATOM 1885c OH2 TIP3W1922 -44.191 -25.792 70.179 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100446  
ATOM 1885d H1 TIP3W1922 -44.418 -25.942 71.097 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100447  
ATOM 1885e H2 TIP3W1922 -45.026 -25.840 69.714 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 18860  
Duplicate atom serial number found: 18861  
Duplicate atom serial number found: 18862  
Duplicate atom serial number found: 18863  
Duplicate atom serial number found: 18864  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 100459  
ATOM 1886a H2 TIP3W1926 -56.158 206.224 22.583 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100460  
ATOM 1886b OH2 TIP3W1927 24.430 -27.913 56.457 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100461  
ATOM 1886c H1 TIP3W1927 24.258 -28.227 55.569 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100462  
ATOM 1886d H2 TIP3W1927 24.234 -26.977 56.422 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100463  
ATOM 1886e OH2 TIP3W1928 -20.695 -57.695 -12.254 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 18870  
Duplicate atom serial number found: 18871  
Duplicate atom serial number found: 18872  
Duplicate atom serial number found: 18873  
Duplicate atom serial number found: 18874  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 100475  
ATOM 1887a OH2 TIP3W1932 141.262 -30.239 -14.147 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100476  
ATOM 1887b H1 TIP3W1932 141.055 -31.145 -14.376 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100477  
ATOM 1887c H2 TIP3W1932 141.874 -29.954 -14.825 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100478  
ATOM 1887d OH2 TIP3W1933 153.611 -69.157 -1.633 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100479  
ATOM 1887e H1 TIP3W1933 152.795 -68.854 -2.031 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 18880  
Duplicate atom serial number found: 18881  
Duplicate atom serial number found: 18882  
Duplicate atom serial number found: 18883  
Duplicate atom serial number found: 18884  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 100491  
ATOM 1888a H1 TIP3W1937 -32.156 -31.546 -38.074 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100492  
ATOM 1888b H2 TIP3W1937 -30.843 -30.973 -37.586 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100493  
ATOM 1888c OH2 TIP3W1938 171.672 207.964 -48.380 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100494  
ATOM 1888d H1 TIP3W1938 172.422 207.412 -48.600 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100495  
ATOM 1888e H2 TIP3W1938 170.969 207.652 -48.949 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 18890  
Duplicate atom serial number found: 18891  
Duplicate atom serial number found: 18892  
Duplicate atom serial number found: 18893  
Duplicate atom serial number found: 18894  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 100507  
ATOM 1889a H2 TIP3W1942 147.935 -40.626 -15.396 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100508  
ATOM 1889b OH2 TIP3W1943 -32.810 3.074 -58.259 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100509  
ATOM 1889c H1 TIP3W1943 -33.313 2.571 -58.900 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100510  
ATOM 1889d H2 TIP3W1943 -33.426 3.238 -57.545 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100511  
ATOM 1889e OH2 TIP3W1944 174.571 163.451 -22.780 0.00 0.00 WT2  
  
97 messages similar to the above omitted  
Duplicate atom serial number found: 18900  
Duplicate atom serial number found: 18901  
Duplicate atom serial number found: 18902  
Duplicate atom serial number found: 18903  
Duplicate atom serial number found: 18904  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 100619  
ATOM 1890a OH2 TIP3W1980 167.840 -19.575 34.727 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100620  
ATOM 1890b H1 TIP3W1980 167.504 -19.480 35.618 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100621  
ATOM 1890c H2 TIP3W1980 168.627 -19.031 34.707 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100622  
ATOM 1890d OH2 TIP3W1981 -39.195 28.297 -39.798 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100623  
ATOM 1890e H1 TIP3W1981 -39.997 27.966 -39.394 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 18910  
Duplicate atom serial number found: 18911  
Duplicate atom serial number found: 18912  
Duplicate atom serial number found: 18913  
Duplicate atom serial number found: 18914  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 100635  
ATOM 1891a H1 TIP3W1985 -42.329 205.332 39.911 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100636  
ATOM 1891b H2 TIP3W1985 -41.007 204.595 39.859 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100637  
ATOM 1891c OH2 TIP3W1986 -22.879 12.691 -22.359 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100638  
ATOM 1891d H1 TIP3W1986 -22.481 12.660 -23.229 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100639  
ATOM 1891e H2 TIP3W1986 -22.860 11.784 -22.054 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 18920  
Duplicate atom serial number found: 18921  
Duplicate atom serial number found: 18922  
Duplicate atom serial number found: 18923  
Duplicate atom serial number found: 18924  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 100651  
ATOM 1892a H2 TIP3W1990 -42.761 198.274 21.765 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100652  
ATOM 1892b OH2 TIP3W1991 -24.393 -53.568 48.910 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100653  
ATOM 1892c H1 TIP3W1991 -24.507 -54.228 48.226 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100654  
ATOM 1892d H2 TIP3W1991 -24.963 -52.846 48.645 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100655  
ATOM 1892e OH2 TIP3W1992 158.179 -58.498 13.764 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 18930  
Duplicate atom serial number found: 18931  
Duplicate atom serial number found: 18932  
Duplicate atom serial number found: 18933  
Duplicate atom serial number found: 18934  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 100667  
ATOM 1893a OH2 TIP3W1996 135.120 -40.674 45.762 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100668  
ATOM 1893b H1 TIP3W1996 134.363 -40.458 46.306 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100669  
ATOM 1893c H2 TIP3W1996 135.600 -39.850 45.681 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100670  
ATOM 1893d OH2 TIP3W1997 -21.725 -29.203 -26.765 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100671  
ATOM 1893e H1 TIP3W1997 -22.649 -29.243 -27.011 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 18940  
Duplicate atom serial number found: 18941  
Duplicate atom serial number found: 18942  
Duplicate atom serial number found: 18943  
Duplicate atom serial number found: 18944  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 100683  
ATOM 1894a H1 TIP3W2001 164.543 28.182 -81.602 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100684  
ATOM 1894b H2 TIP3W2001 165.463 27.412 -80.678 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100685  
ATOM 1894c OH2 TIP3W2002 147.996 2.311 -63.509 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100686  
ATOM 1894d H1 TIP3W2002 147.908 2.293 -64.462 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100687  
ATOM 1894e H2 TIP3W2002 147.276 1.766 -63.191 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 18950  
Duplicate atom serial number found: 18951  
Duplicate atom serial number found: 18952  
Duplicate atom serial number found: 18953  
Duplicate atom serial number found: 18954  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 100699  
ATOM 1895a H2 TIP3W2006 5.904 -57.173 -38.265 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100700  
ATOM 1895b OH2 TIP3W2007 -58.446 171.324 6.936 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100701  
ATOM 1895c H1 TIP3W2007 -58.478 171.888 7.709 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100702  
ATOM 1895d H2 TIP3W2007 -59.364 171.153 6.725 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100703  
ATOM 1895e OH2 TIP3W2008 -24.737 -46.853 36.835 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 18960  
Duplicate atom serial number found: 18961  
Duplicate atom serial number found: 18962  
Duplicate atom serial number found: 18963  
Duplicate atom serial number found: 18964  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 100715  
ATOM 1896a OH2 TIP3W2012 -6.597 168.958 -45.945 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100716  
ATOM 1896b H1 TIP3W2012 -6.484 169.909 -45.969 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100717  
ATOM 1896c H2 TIP3W2012 -7.415 168.825 -45.467 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100718  
ATOM 1896d OH2 TIP3W2013 156.886 -18.219 -32.789 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100719  
ATOM 1896e H1 TIP3W2013 156.315 -18.843 -33.238 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 18970  
Duplicate atom serial number found: 18971  
Duplicate atom serial number found: 18972  
Duplicate atom serial number found: 18973  
Duplicate atom serial number found: 18974  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 100731  
ATOM 1897a H1 TIP3W2017 175.682 -50.204 86.646 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100732  
ATOM 1897b H2 TIP3W2017 175.236 -49.061 85.760 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100733  
ATOM 1897c OH2 TIP3W2018 -26.598 -11.184 -60.419 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100734  
ATOM 1897d H1 TIP3W2018 -26.892 -10.315 -60.146 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100735  
ATOM 1897e H2 TIP3W2018 -26.330 -11.072 -61.331 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 18980  
Duplicate atom serial number found: 18981  
Duplicate atom serial number found: 18982  
Duplicate atom serial number found: 18983  
Duplicate atom serial number found: 18984  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 100747  
ATOM 1898a H2 TIP3W2022 106.464 -17.012 -68.025 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100748  
ATOM 1898b OH2 TIP3W2023 158.870 -32.961 -24.087 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100749  
ATOM 1898c H1 TIP3W2023 158.932 -33.916 -24.056 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100750  
ATOM 1898d H2 TIP3W2023 159.340 -32.716 -24.884 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100751  
ATOM 1898e OH2 TIP3W2024 173.326 -39.513 26.560 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 18990  
Duplicate atom serial number found: 18991  
Duplicate atom serial number found: 18992  
Duplicate atom serial number found: 18993  
Duplicate atom serial number found: 18994  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 100763  
ATOM 1899a OH2 TIP3W2028 -4.098 -21.995 -29.903 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100764  
ATOM 1899b H1 TIP3W2028 -4.549 -21.510 -29.212 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100765  
ATOM 1899c H2 TIP3W2028 -4.323 -22.911 -29.739 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100766  
ATOM 1899d OH2 TIP3W2029 -32.826 -8.567 -7.055 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 100767  
ATOM 1899e H1 TIP3W2029 -33.608 -8.169 -7.437 0.00 0.00 WT2  
  
1633 messages similar to the above omitted  
Duplicate atom serial number found: 19000  
Duplicate atom serial number found: 19001  
Duplicate atom serial number found: 19002  
Duplicate atom serial number found: 19003  
Duplicate atom serial number found: 19004  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 102411  
ATOM 1900a H1 TIP3W2583 112.680 -58.664 69.138 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102412  
ATOM 1900b H2 TIP3W2583 112.307 -57.395 68.402 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102413  
ATOM 1900c OH2 TIP3W2584 -67.719 -55.734 -34.592 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102414  
ATOM 1900d H1 TIP3W2584 -68.254 -55.604 -33.808 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102415  
ATOM 1900e H2 TIP3W2584 -67.987 -55.032 -35.184 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 19010  
Duplicate atom serial number found: 19011  
Duplicate atom serial number found: 19012  
Duplicate atom serial number found: 19013  
Duplicate atom serial number found: 19014  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 102427  
ATOM 1901a H2 TIP3W2588 14.116 -10.890 -66.217 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102428  
ATOM 1901b OH2 TIP3W2589 -57.339 -28.045 -9.235 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102429  
ATOM 1901c H1 TIP3W2589 -56.784 -28.768 -9.527 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102430  
ATOM 1901d H2 TIP3W2589 -58.215 -28.274 -9.546 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102431  
ATOM 1901e OH2 TIP3W2590 -66.912 204.237 53.132 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 19020  
Duplicate atom serial number found: 19021  
Duplicate atom serial number found: 19022  
Duplicate atom serial number found: 19023  
Duplicate atom serial number found: 19024  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 102443  
ATOM 1902a OH2 TIP3W2594 -32.845 -5.384 -2.351 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102444  
ATOM 1902b H1 TIP3W2594 -32.770 -4.523 -2.763 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102445  
ATOM 1902c H2 TIP3W2594 -33.522 -5.273 -1.684 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102446  
ATOM 1902d OH2 TIP3W2595 -47.085 39.628 4.780 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102447  
ATOM 1902e H1 TIP3W2595 -46.615 38.838 4.514 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 19030  
Duplicate atom serial number found: 19031  
Duplicate atom serial number found: 19032  
Duplicate atom serial number found: 19033  
Duplicate atom serial number found: 19034  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 102459  
ATOM 1903a H1 TIP3W2600 -40.144 9.230 64.655 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102460  
ATOM 1903b H2 TIP3W2600 -40.680 8.012 63.933 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102461  
ATOM 1903c OH2 TIP3W2601 -31.360 -29.565 -21.938 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102462  
ATOM 1903d H1 TIP3W2601 -32.298 -29.552 -22.130 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102463  
ATOM 1903e H2 TIP3W2601 -30.940 -29.429 -22.787 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 19040  
Duplicate atom serial number found: 19041  
Duplicate atom serial number found: 19042  
Duplicate atom serial number found: 19043  
Duplicate atom serial number found: 19044  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 102475  
ATOM 1904a H2 TIP3W2605 -18.251 -40.968 -33.257 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102476  
ATOM 1904b OH2 TIP3W2606 147.954 29.883 -53.652 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102477  
ATOM 1904c H1 TIP3W2606 148.691 29.632 -53.094 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102478  
ATOM 1904d H2 TIP3W2606 147.468 29.069 -53.788 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102479  
ATOM 1904e OH2 TIP3W2607 -55.656 167.823 -34.912 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 19050  
Duplicate atom serial number found: 19051  
Duplicate atom serial number found: 19052  
Duplicate atom serial number found: 19053  
Duplicate atom serial number found: 19054  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 102491  
ATOM 1905a OH2 TIP3W2611 -31.036 0.604 -59.536 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102492  
ATOM 1905b H1 TIP3W2611 -31.102 1.364 -58.957 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102493  
ATOM 1905c H2 TIP3W2611 -30.918 0.978 -60.409 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102494  
ATOM 1905d OH2 TIP3W2612 160.270 -0.203 42.148 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102495  
ATOM 1905e H1 TIP3W2612 159.766 0.246 41.470 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 19060  
Duplicate atom serial number found: 19061  
Duplicate atom serial number found: 19062  
Duplicate atom serial number found: 19063  
Duplicate atom serial number found: 19064  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 102507  
ATOM 1906a H1 TIP3W2616 -49.481 -20.777 16.980 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102508  
ATOM 1906b H2 TIP3W2616 -49.478 -19.700 18.043 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102509  
ATOM 1906c OH2 TIP3W2617 -68.666 0.265 28.449 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102510  
ATOM 1906d H1 TIP3W2617 -67.869 0.430 28.952 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102511  
ATOM 1906e H2 TIP3W2617 -68.688 -0.685 28.339 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 19070  
Duplicate atom serial number found: 19071  
Duplicate atom serial number found: 19072  
Duplicate atom serial number found: 19073  
Duplicate atom serial number found: 19074  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 102523  
ATOM 1907a H2 TIP3W2621 -37.371 181.928 7.052 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102524  
ATOM 1907b OH2 TIP3W2622 -35.740 -53.669 51.104 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102525  
ATOM 1907c H1 TIP3W2622 -34.848 -54.002 51.007 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102526  
ATOM 1907d H2 TIP3W2622 -35.627 -52.750 51.349 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102527  
ATOM 1907e OH2 TIP3W2623 147.376 153.945 -17.165 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 19080  
Duplicate atom serial number found: 19081  
Duplicate atom serial number found: 19082  
Duplicate atom serial number found: 19083  
Duplicate atom serial number found: 19084  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 102539  
ATOM 1908a OH2 TIP3W2628 157.882 167.926 -54.730 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102540  
ATOM 1908b H1 TIP3W2628 157.305 168.665 -54.920 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102541  
ATOM 1908c H2 TIP3W2628 158.037 167.978 -53.787 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102542  
ATOM 1908d OH2 TIP3W2629 129.461 195.735 -5.350 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102543  
ATOM 1908e H1 TIP3W2629 128.592 195.528 -5.006 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 19090  
Duplicate atom serial number found: 19091  
Duplicate atom serial number found: 19092  
Duplicate atom serial number found: 19093  
Duplicate atom serial number found: 19094  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 102555  
ATOM 1909a H1 TIP3W2634 128.989 -29.214 -21.712 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102556  
ATOM 1909b H2 TIP3W2634 127.889 -28.948 -20.707 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102557  
ATOM 1909c OH2 TIP3W2635 -55.633 -45.527 -35.331 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102558  
ATOM 1909d H1 TIP3W2635 -55.392 -46.451 -35.255 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102559  
ATOM 1909e H2 TIP3W2635 -56.110 -45.471 -36.159 0.00 0.00 WT2  
  
97 messages similar to the above omitted  
Duplicate atom serial number found: 19100  
Duplicate atom serial number found: 19101  
Duplicate atom serial number found: 19102  
Duplicate atom serial number found: 19103  
Duplicate atom serial number found: 19104  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 102667  
ATOM 1910a H2 TIP3W2672 57.093 -45.113 2.222 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102668  
ATOM 1910b OH2 TIP3W2673 116.450 -68.963 -16.213 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102669  
ATOM 1910c H1 TIP3W2673 116.362 -69.286 -17.110 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102670  
ATOM 1910d H2 TIP3W2673 117.209 -68.381 -16.241 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102671  
ATOM 1910e OH2 TIP3W2674 4.418 -46.426 43.060 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 19110  
Duplicate atom serial number found: 19111  
Duplicate atom serial number found: 19112  
Duplicate atom serial number found: 19113  
Duplicate atom serial number found: 19114  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 102683  
ATOM 1911a OH2 TIP3W2678 -21.345 209.890 50.947 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102684  
ATOM 1911b H1 TIP3W2678 -22.258 209.608 51.002 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102685  
ATOM 1911c H2 TIP3W2678 -21.330 210.514 50.221 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102686  
ATOM 1911d OH2 TIP3W2679 -11.345 -26.033 -48.782 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102687  
ATOM 1911e H1 TIP3W2679 -11.744 -26.902 -48.735 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 19120  
Duplicate atom serial number found: 19121  
Duplicate atom serial number found: 19122  
Duplicate atom serial number found: 19123  
Duplicate atom serial number found: 19124  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 102699  
ATOM 1912a H1 TIP3W2683 6.578 179.633 15.117 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102700  
ATOM 1912b H2 TIP3W2683 5.726 180.383 14.116 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102701  
ATOM 1912c OH2 TIP3W2684 166.033 -54.554 18.899 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102702  
ATOM 1912d H1 TIP3W2684 166.457 -53.773 18.544 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102703  
ATOM 1912e H2 TIP3W2684 166.614 -55.275 18.655 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 19130  
Duplicate atom serial number found: 19131  
Duplicate atom serial number found: 19132  
Duplicate atom serial number found: 19133  
Duplicate atom serial number found: 19134  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 102715  
ATOM 1913a H2 TIP3W2688 152.910 -12.747 -5.354 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102716  
ATOM 1913b OH2 TIP3W2689 143.985 -37.625 -35.292 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102717  
ATOM 1913c H1 TIP3W2689 143.489 -36.938 -34.848 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102718  
ATOM 1913d H2 TIP3W2689 143.652 -38.442 -34.920 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102719  
ATOM 1913e OH2 TIP3W2690 166.611 -31.905 -45.761 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 19140  
Duplicate atom serial number found: 19141  
Duplicate atom serial number found: 19142  
Duplicate atom serial number found: 19143  
Duplicate atom serial number found: 19144  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 102731  
ATOM 1914a OH2 TIP3W2694 -67.227 210.469 -9.671 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102732  
ATOM 1914b H1 TIP3W2694 -67.298 209.529 -9.840 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102733  
ATOM 1914c H2 TIP3W2694 -67.498 210.571 -8.759 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102734  
ATOM 1914d OH2 TIP3W2695 -31.827 191.114 -29.237 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102735  
ATOM 1914e H1 TIP3W2695 -32.348 190.436 -28.806 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 19150  
Duplicate atom serial number found: 19151  
Duplicate atom serial number found: 19152  
Duplicate atom serial number found: 19153  
Duplicate atom serial number found: 19154  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 102747  
ATOM 1915a H1 TIP3W2699 -59.842 -44.845 38.188 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102748  
ATOM 1915b H2 TIP3W2699 -59.417 -45.119 39.615 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102749  
ATOM 1915c OH2 TIP3W2700 -16.048 182.168 31.624 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102750  
ATOM 1915d H1 TIP3W2700 -16.977 182.306 31.435 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102751  
ATOM 1915e H2 TIP3W2700 -15.684 183.051 31.695 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 19160  
Duplicate atom serial number found: 19161  
Duplicate atom serial number found: 19162  
Duplicate atom serial number found: 19163  
Duplicate atom serial number found: 19164  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 102763  
ATOM 1916a H2 TIP3W2704 -14.197 -46.421 -48.680 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102764  
ATOM 1916b OH2 TIP3W2705 163.714 -7.589 92.319 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102765  
ATOM 1916c H1 TIP3W2705 163.412 -7.740 93.215 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102766  
ATOM 1916d H2 TIP3W2705 162.936 -7.720 91.778 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102767  
ATOM 1916e OH2 TIP3W2706 113.571 -52.413 -51.109 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 19170  
Duplicate atom serial number found: 19171  
Duplicate atom serial number found: 19172  
Duplicate atom serial number found: 19173  
Duplicate atom serial number found: 19174  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 102779  
ATOM 1917a OH2 TIP3W2710 146.659 -20.630 -67.790 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102780  
ATOM 1917b H1 TIP3W2710 147.291 -20.295 -67.154 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102781  
ATOM 1917c H2 TIP3W2710 147.189 -20.866 -68.552 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102782  
ATOM 1917d OH2 TIP3W2711 -19.923 196.540 40.669 0.00 0.00 WT2  
  
Ignored bad PDB record found on line 102783  
ATOM 1917e H1 TIP3W2711 -20.179 196.754 39.772 0.00 0.00 WT2  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 19180  
Duplicate atom serial number found: 19181  
Duplicate atom serial number found: 19182  
Duplicate atom serial number found: 19183  
Duplicate atom serial number found: 19184  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 102795  
ATOM 1918a H1 TIP3W2715 -12.757 -53.746 -32.131 0.00 0.00 WT2  
  

[much of the log deleted to fit within ticket size limits]
  
Ignored bad PDB record found on line 628831  
ATOM 9985e H2 TIP3W8985 32.893 144.186 84.417 0.00 0.00 WT1C  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 99860  
Duplicate atom serial number found: 99861  
Duplicate atom serial number found: 99862  
Duplicate atom serial number found: 99863  
Duplicate atom serial number found: 99864  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 628843  
ATOM 9986a H2 TIP3W8989 50.431 14.603 129.039 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 628844  
ATOM 9986b OH2 TIP3W8990 24.247 -49.589 -26.616 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 628845  
ATOM 9986c H1 TIP3W8990 23.921 -48.790 -26.203 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 628846  
ATOM 9986d H2 TIP3W8990 23.881 -49.568 -27.501 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 628847  
ATOM 9986e OH2 TIP3W8991 64.412 -69.916 10.151 0.00 0.00 WT1C  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 99870  
Duplicate atom serial number found: 99871  
Duplicate atom serial number found: 99872  
Duplicate atom serial number found: 99873  
Duplicate atom serial number found: 99874  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 628859  
ATOM 9987a OH2 TIP3W8995 6.414 -68.573 32.432 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 628860  
ATOM 9987b H1 TIP3W8995 7.233 -68.401 31.969 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 628861  
ATOM 9987c H2 TIP3W8995 6.536 -69.437 32.825 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 628862  
ATOM 9987d OH2 TIP3W8996 38.240 -6.014 45.498 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 628863  
ATOM 9987e H1 TIP3W8996 38.724 -5.294 45.095 0.00 0.00 WT1C  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 99880  
Duplicate atom serial number found: 99881  
Duplicate atom serial number found: 99882  
Duplicate atom serial number found: 99883  
Duplicate atom serial number found: 99884  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 628875  
ATOM 9988a H1 TIP3W9000 27.809 -39.160 39.441 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 628876  
ATOM 9988b H2 TIP3W9000 29.060 -39.244 40.289 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 628877  
ATOM 9988c OH2 TIP3W9001 81.618 194.283 116.061 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 628878  
ATOM 9988d H1 TIP3W9001 81.977 194.708 115.282 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 628879  
ATOM 9988e H2 TIP3W9001 82.067 193.438 116.101 0.00 0.00 WT1C  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 99890  
Duplicate atom serial number found: 99891  
Duplicate atom serial number found: 99892  
Duplicate atom serial number found: 99893  
Duplicate atom serial number found: 99894  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 628891  
ATOM 9989a H2 TIP3W9005 -16.658 -30.813 101.364 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 628892  
ATOM 9989b OH2 TIP3W9006 49.679 -51.328 49.820 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 628893  
ATOM 9989c H1 TIP3W9006 48.978 -51.300 50.471 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 628894  
ATOM 9989d H2 TIP3W9006 49.980 -52.237 49.831 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 628895  
ATOM 9989e OH2 TIP3W9007 25.385 -55.835 121.040 0.00 0.00 WT1C  
  
97 messages similar to the above omitted  
Duplicate atom serial number found: 99900  
Duplicate atom serial number found: 99901  
Duplicate atom serial number found: 99902  
Duplicate atom serial number found: 99903  
Duplicate atom serial number found: 99904  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 629003  
ATOM 9990a OH2 TIP3W9043 67.624 203.443 27.837 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629004  
ATOM 9990b H1 TIP3W9043 68.410 203.847 27.470 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629005  
ATOM 9990c H2 TIP3W9043 67.429 202.716 27.245 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629006  
ATOM 9990d OH2 TIP3W9044 51.167 -18.790 117.549 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629007  
ATOM 9990e H1 TIP3W9044 51.700 -18.001 117.643 0.00 0.00 WT1C  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 99910  
Duplicate atom serial number found: 99911  
Duplicate atom serial number found: 99912  
Duplicate atom serial number found: 99913  
Duplicate atom serial number found: 99914  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 629019  
ATOM 9991a H1 TIP3W9048 78.495 -60.680 66.613 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629020  
ATOM 9991b H2 TIP3W9048 78.122 -59.354 67.241 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629021  
ATOM 9991c OH2 TIP3W9050 34.514 201.199 -99.203 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629022  
ATOM 9991d H1 TIP3W9050 33.997 201.216-100.008 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629023  
ATOM 9991e H2 TIP3W9050 35.054 201.988 -99.249 0.00 0.00 WT1C  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 99920  
Duplicate atom serial number found: 99921  
Duplicate atom serial number found: 99922  
Duplicate atom serial number found: 99923  
Duplicate atom serial number found: 99924  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 629035  
ATOM 9992a H2 TIP3W9054 66.267 -22.628 33.310 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629036  
ATOM 9992b OH2 TIP3W9055 9.462 -63.764 -3.384 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629037  
ATOM 9992c H1 TIP3W9055 8.688 -63.241 -3.591 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629038  
ATOM 9992d H2 TIP3W9055 9.696 -64.185 -4.212 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629039  
ATOM 9992e OH2 TIP3W9056 61.643 -29.039 0.994 0.00 0.00 WT1C  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 99930  
Duplicate atom serial number found: 99931  
Duplicate atom serial number found: 99932  
Duplicate atom serial number found: 99933  
Duplicate atom serial number found: 99934  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 629051  
ATOM 9993a OH2 TIP3W9060 44.712 187.688 1.333 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629052  
ATOM 9993b H1 TIP3W9060 44.472 187.408 2.216 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629053  
ATOM 9993c H2 TIP3W9060 45.030 188.584 1.443 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629054  
ATOM 9993d OH2 TIP3W9061 65.151 -38.670 80.592 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629055  
ATOM 9993e H1 TIP3W9061 65.351 -37.743 80.457 0.00 0.00 WT1C  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 99940  
Duplicate atom serial number found: 99941  
Duplicate atom serial number found: 99942  
Duplicate atom serial number found: 99943  
Duplicate atom serial number found: 99944  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 629067  
ATOM 9994a H1 TIP3W9065 25.223 -52.757 116.660 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629068  
ATOM 9994b H2 TIP3W9065 26.165 -52.529 115.497 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629069  
ATOM 9994c OH2 TIP3W9066 12.938 -41.753 39.212 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629070  
ATOM 9994d H1 TIP3W9066 12.874 -41.792 40.167 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629071  
ATOM 9994e H2 TIP3W9066 12.936 -40.818 39.009 0.00 0.00 WT1C  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 99950  
Duplicate atom serial number found: 99951  
Duplicate atom serial number found: 99952  
Duplicate atom serial number found: 99953  
Duplicate atom serial number found: 99954  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 629083  
ATOM 9995a H2 TIP3W9070 18.910 206.151 83.214 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629084  
ATOM 9995b OH2 TIP3W9071 7.243 200.888 96.087 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629085  
ATOM 9995c H1 TIP3W9071 7.200 199.937 95.996 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629086  
ATOM 9995d H2 TIP3W9071 7.221 201.217 95.189 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629087  
ATOM 9995e OH2 TIP3W9072 80.409 24.558 42.277 0.00 0.00 WT1C  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 99960  
Duplicate atom serial number found: 99961  
Duplicate atom serial number found: 99962  
Duplicate atom serial number found: 99963  
Duplicate atom serial number found: 99964  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 629099  
ATOM 9996a OH2 TIP3W9078 39.790 -40.510 29.229 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629100  
ATOM 9996b H1 TIP3W9078 40.493 -39.877 29.083 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629101  
ATOM 9996c H2 TIP3W9078 39.536 -40.380 30.142 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629102  
ATOM 9996d OH2 TIP3W9079 26.654 -55.963 15.492 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629103  
ATOM 9996e H1 TIP3W9079 27.217 -55.247 15.787 0.00 0.00 WT1C  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 99970  
Duplicate atom serial number found: 99971  
Duplicate atom serial number found: 99972  
Duplicate atom serial number found: 99973  
Duplicate atom serial number found: 99974  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 629115  
ATOM 9997a H1 TIP3W9084 61.717 -34.637 51.044 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629116  
ATOM 9997b H2 TIP3W9084 61.442 -33.679 52.183 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629117  
ATOM 9997c OH2 TIP3W9085 29.042 -18.650 58.652 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629118  
ATOM 9997d H1 TIP3W9085 29.044 -19.563 58.364 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629119  
ATOM 9997e H2 TIP3W9085 29.242 -18.149 57.861 0.00 0.00 WT1C  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 99980  
Duplicate atom serial number found: 99981  
Duplicate atom serial number found: 99982  
Duplicate atom serial number found: 99983  
Duplicate atom serial number found: 99984  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 629131  
ATOM 9998a H2 TIP3W9089 100.328 -36.237 117.222 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629132  
ATOM 9998b OH2 TIP3W9090 94.300 -64.579 94.847 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629133  
ATOM 9998c H1 TIP3W9090 94.728 -63.731 94.733 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629134  
ATOM 9998d H2 TIP3W9090 93.504 -64.519 94.318 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629135  
ATOM 9998e OH2 TIP3W9092 26.032 -10.885 39.794 0.00 0.00 WT1C  
  
1 messages similar to the above omitted  
Duplicate atom serial number found: 99990  
Duplicate atom serial number found: 99991  
Duplicate atom serial number found: 99992  
Duplicate atom serial number found: 99993  
Duplicate atom serial number found: 99994  
5 messages similar to the above omitted  
Ignored bad PDB record found on line 629147  
ATOM 9999a OH2 TIP3W9097 -26.592 -33.405 61.274 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629148  
ATOM 9999b H1 TIP3W9097 -26.385 -34.329 61.133 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629149  
ATOM 9999c H2 TIP3W9097 -27.515 -33.403 61.528 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629150  
ATOM 9999d OH2 TIP3W9098 16.641 183.889 -19.620 0.00 0.00 WT1C  
  
Ignored bad PDB record found on line 629151  
ATOM 9999e H1 TIP3W9098 16.465 184.757 -19.982 0.00 0.00 WT1C  
  
419425 messages similar to the above omitted  
  
Chain information for actomyo_2_myos_5actins_step5.pdb #2  
---  
Chain | Description  
A B C D E | No description available  
F | No description available  
L Q | No description available  
M N O R S T | No description available  
  
Traceback (most recent call last):  
File
"/Applications/ChimeraX-1.2.5.app/Contents/Library/Frameworks/Python.framework/Versions/3.8/lib/python3.8/site-
packages/chimerax/core/triggerset.py", line 130, in invoke  
return self._func(self._name, data)  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 1013, in _update_model_list  
mmcb.blockSignals(True)  
RuntimeError: wrapped C/C++ object of type WinAutoResizeQComboBox has been
deleted  
  
Error processing trigger "add models":  
RuntimeError: wrapped C/C++ object of type WinAutoResizeQComboBox has been
deleted  
  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 1013, in _update_model_list  
mmcb.blockSignals(True)  
  
See log for complete Python traceback.  
  

> close #2

Deleting atomic symmetry model...  
Traceback (most recent call last):  
File
"/Applications/ChimeraX-1.2.5.app/Contents/Library/Frameworks/Python.framework/Versions/3.8/lib/python3.8/site-
packages/chimerax/core/triggerset.py", line 130, in invoke  
return self._func(self._name, data)  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 1013, in _update_model_list  
mmcb.blockSignals(True)  
RuntimeError: wrapped C/C++ object of type WinAutoResizeQComboBox has been
deleted  
  
Error processing trigger "remove models":  
RuntimeError: wrapped C/C++ object of type WinAutoResizeQComboBox has been
deleted  
  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 1013, in _update_model_list  
mmcb.blockSignals(True)  
  
See log for complete Python traceback.  
  

> open
> /Users/henryshuman/Documents/NAMD/myo1c_into_P19_J544/actomyo_2_myos_5actins_end_of_step5.pdb

Chain information for actomyo_2_myos_5actins_end_of_step5.pdb #2  
---  
Chain | Description  
A B C D E | No description available  
F | No description available  
L Q | No description available  
M N O R S T | No description available  
  
Traceback (most recent call last):  
File
"/Applications/ChimeraX-1.2.5.app/Contents/Library/Frameworks/Python.framework/Versions/3.8/lib/python3.8/site-
packages/chimerax/core/triggerset.py", line 130, in invoke  
return self._func(self._name, data)  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 1013, in _update_model_list  
mmcb.blockSignals(True)  
RuntimeError: wrapped C/C++ object of type WinAutoResizeQComboBox has been
deleted  
  
Error processing trigger "add models":  
RuntimeError: wrapped C/C++ object of type WinAutoResizeQComboBox has been
deleted  
  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 1013, in _update_model_list  
mmcb.blockSignals(True)  
  
See log for complete Python traceback.  
  

> ui tool show ISOLDE

> set selectionWidth 4

Deleting atomic symmetry model...  
Traceback (most recent call last):  
File
"/Applications/ChimeraX-1.2.5.app/Contents/Library/Frameworks/Python.framework/Versions/3.8/lib/python3.8/site-
packages/chimerax/core/triggerset.py", line 130, in invoke  
return self._func(self._name, data)  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 1013, in _update_model_list  
mmcb.blockSignals(True)  
RuntimeError: wrapped C/C++ object of type WinAutoResizeQComboBox has been
deleted  
  
Error processing trigger "remove models":  
RuntimeError: wrapped C/C++ object of type WinAutoResizeQComboBox has been
deleted  
  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 1013, in _update_model_list  
mmcb.blockSignals(True)  
  
See log for complete Python traceback.  
  
Chain information for actomyo_2_myos_5actins_end_of_step5.pdb  
---  
Chain | Description  
2.2/A 2.2/B 2.2/C 2.2/D 2.2/E | No description available  
2.2/F | No description available  
2.2/L 2.2/Q | No description available  
2.2/M 2.2/N 2.2/O 2.2/R 2.2/S 2.2/T | No description available  
  
Traceback (most recent call last):  
File
"/Applications/ChimeraX-1.2.5.app/Contents/Library/Frameworks/Python.framework/Versions/3.8/lib/python3.8/site-
packages/chimerax/core/triggerset.py", line 130, in invoke  
return self._func(self._name, data)  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 1013, in _update_model_list  
mmcb.blockSignals(True)  
RuntimeError: wrapped C/C++ object of type WinAutoResizeQComboBox has been
deleted  
  
Error processing trigger "add models":  
RuntimeError: wrapped C/C++ object of type WinAutoResizeQComboBox has been
deleted  
  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 1013, in _update_model_list  
mmcb.blockSignals(True)  
  
See log for complete Python traceback.  
  
Traceback (most recent call last):  
File
"/Applications/ChimeraX-1.2.5.app/Contents/Library/Frameworks/Python.framework/Versions/3.8/lib/python3.8/site-
packages/chimerax/core/triggerset.py", line 130, in invoke  
return self._func(self._name, data)  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 1044, in _update_model_list  
self._change_selected_model(model=current_model)  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 2478, in _change_selected_model  
self._update_iffy_rota_list()  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 2389, in _update_iffy_rota_list  
if not table.isVisible():  
RuntimeError: wrapped C/C++ object of type QTableWidget has been deleted  
  
Error processing trigger "add models":  
RuntimeError: wrapped C/C++ object of type QTableWidget has been deleted  
  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 2389, in _update_iffy_rota_list  
if not table.isVisible():  
  
See log for complete Python traceback.  
  
Traceback (most recent call last):  
File
"/Applications/ChimeraX-1.2.5.app/Contents/Library/Frameworks/Python.framework/Versions/3.8/lib/python3.8/site-
packages/chimerax/core/triggerset.py", line 130, in invoke  
return self._func(self._name, data)  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 1044, in _update_model_list  
self._change_selected_model(model=current_model)  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 2478, in _change_selected_model  
self._update_iffy_rota_list()  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 2389, in _update_iffy_rota_list  
if not table.isVisible():  
RuntimeError: wrapped C/C++ object of type QTableWidget has been deleted  
  
Error processing trigger "add models":  
RuntimeError: wrapped C/C++ object of type QTableWidget has been deleted  
  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 2389, in _update_iffy_rota_list  
if not table.isVisible():  
  
See log for complete Python traceback.  
  
Traceback (most recent call last):  
File
"/Applications/ChimeraX-1.2.5.app/Contents/Library/Frameworks/Python.framework/Versions/3.8/lib/python3.8/site-
packages/chimerax/core/triggerset.py", line 130, in invoke  
return self._func(self._name, data)  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 1044, in _update_model_list  
self._change_selected_model(model=current_model)  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 2478, in _change_selected_model  
self._update_iffy_rota_list()  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 2389, in _update_iffy_rota_list  
if not table.isVisible():  
RuntimeError: wrapped C/C++ object of type QTableWidget has been deleted  
  
Error processing trigger "add models":  
RuntimeError: wrapped C/C++ object of type QTableWidget has been deleted  
  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 2389, in _update_iffy_rota_list  
if not table.isVisible():  
  
See log for complete Python traceback.  
  
Done loading forcefield  

> ui tool show ISOLDE

> isolde pepflip

Missing or invalid "atoms" argument: empty atom specifier  

> isolde pepflip @271

Flipping the peptide bond for 0 residues  
No atoms selected!  

> isolde pepflip E271

Missing or invalid "atoms" argument: invalid atoms specifier  

> select clear

> isolde pepflip /E 271

Expected fewer arguments  

> isolde pepflip /E271

Flipping the peptide bond for 0 residues  
No atoms selected!  

> isolde pepflip E271

Missing or invalid "atoms" argument: invalid atoms specifier  

> select up

11 atoms, 10 bonds, 1 residue, 1 model selected  

> select clear

> select up

10 atoms, 9 bonds, 1 residue, 1 model selected  

> isolde pepflip E271

Missing or invalid "atoms" argument: invalid atoms specifier  

> isolde pepflip :E271

Flipping the peptide bond for 0 residues  
No atoms selected!  

> isolde pepflip /E:271

Flipping the peptide bond for 1 residues  
Traceback (most recent call last):  
File
"/Applications/ChimeraX-1.2.5.app/Contents/Library/Frameworks/Python.framework/Versions/3.8/lib/python3.8/site-
packages/chimerax/core/triggerset.py", line 130, in invoke  
return self._func(self._name, data)  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 1044, in _update_model_list  
self._change_selected_model(model=current_model)  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 2478, in _change_selected_model  
self._update_iffy_rota_list()  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 2389, in _update_iffy_rota_list  
if not table.isVisible():  
RuntimeError: wrapped C/C++ object of type QTableWidget has been deleted  
  
Error processing trigger "add models":  
RuntimeError: wrapped C/C++ object of type QTableWidget has been deleted  
  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 2389, in _update_iffy_rota_list  
if not table.isVisible():  
  
See log for complete Python traceback.  
  
Traceback (most recent call last):  
File
"/Applications/ChimeraX-1.2.5.app/Contents/Library/Frameworks/Python.framework/Versions/3.8/lib/python3.8/site-
packages/chimerax/core/triggerset.py", line 130, in invoke  
return self._func(self._name, data)  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 1044, in _update_model_list  
self._change_selected_model(model=current_model)  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 2478, in _change_selected_model  
self._update_iffy_rota_list()  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 2389, in _update_iffy_rota_list  
if not table.isVisible():  
RuntimeError: wrapped C/C++ object of type QTableWidget has been deleted  
  
Error processing trigger "add models":  
RuntimeError: wrapped C/C++ object of type QTableWidget has been deleted  
  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 2389, in _update_iffy_rota_list  
if not table.isVisible():  
  
See log for complete Python traceback.  
  
Traceback (most recent call last):  
File
"/Applications/ChimeraX-1.2.5.app/Contents/Library/Frameworks/Python.framework/Versions/3.8/lib/python3.8/site-
packages/chimerax/core/triggerset.py", line 130, in invoke  
return self._func(self._name, data)  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 1044, in _update_model_list  
self._change_selected_model(model=current_model)  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 2478, in _change_selected_model  
self._update_iffy_rota_list()  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 2389, in _update_iffy_rota_list  
if not table.isVisible():  
RuntimeError: wrapped C/C++ object of type QTableWidget has been deleted  
  
Error processing trigger "add models":  
RuntimeError: wrapped C/C++ object of type QTableWidget has been deleted  
  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 2389, in _update_iffy_rota_list  
if not table.isVisible():  
  
See log for complete Python traceback.  
  
Traceback (most recent call last):  
File
"/Applications/ChimeraX-1.2.5.app/Contents/Library/Frameworks/Python.framework/Versions/3.8/lib/python3.8/site-
packages/chimerax/core/triggerset.py", line 130, in invoke  
return self._func(self._name, data)  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 1044, in _update_model_list  
self._change_selected_model(model=current_model)  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 2478, in _change_selected_model  
self._update_iffy_rota_list()  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 2389, in _update_iffy_rota_list  
if not table.isVisible():  
RuntimeError: wrapped C/C++ object of type QTableWidget has been deleted  
  
Error processing trigger "add models":  
RuntimeError: wrapped C/C++ object of type QTableWidget has been deleted  
  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 2389, in _update_iffy_rota_list  
if not table.isVisible():  
  
See log for complete Python traceback.  
  
Traceback (most recent call last):  
File
"/Applications/ChimeraX-1.2.5.app/Contents/Library/Frameworks/Python.framework/Versions/3.8/lib/python3.8/site-
packages/chimerax/core/triggerset.py", line 130, in invoke  
return self._func(self._name, data)  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 1044, in _update_model_list  
self._change_selected_model(model=current_model)  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 2478, in _change_selected_model  
self._update_iffy_rota_list()  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 2389, in _update_iffy_rota_list  
if not table.isVisible():  
RuntimeError: wrapped C/C++ object of type QTableWidget has been deleted  
  
Error processing trigger "add models":  
RuntimeError: wrapped C/C++ object of type QTableWidget has been deleted  
  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 2389, in _update_iffy_rota_list  
if not table.isVisible():  
  
See log for complete Python traceback.  
  
Traceback (most recent call last):  
File
"/Applications/ChimeraX-1.2.5.app/Contents/Library/Frameworks/Python.framework/Versions/3.8/lib/python3.8/site-
packages/chimerax/core/triggerset.py", line 130, in invoke  
return self._func(self._name, data)  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 1044, in _update_model_list  
self._change_selected_model(model=current_model)  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 2478, in _change_selected_model  
self._update_iffy_rota_list()  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 2389, in _update_iffy_rota_list  
if not table.isVisible():  
RuntimeError: wrapped C/C++ object of type QTableWidget has been deleted  
  
Error processing trigger "add models":  
RuntimeError: wrapped C/C++ object of type QTableWidget has been deleted  
  
File "/Users/henryshuman/Library/Application Support/ChimeraX/1.2/site-
packages/chimerax/isolde/isolde.py", line 2389, in _update_iffy_rota_list  
if not table.isVisible():  
  
See log for complete Python traceback.  
  
Loading residue template for ADP from internal database  

Populating font family aliases took 1753 ms. Replace uses of missing font
family "Carlito" with one that exists to avoid this cost.  

ISOLDE: started sim  




OpenGL version: 4.1 INTEL-12.10.12
OpenGL renderer: Intel HD Graphics 5000 OpenGL Engine
OpenGL vendor: Intel Inc.Hardware:

    Hardware Overview:

      Model Name: iMac
      Model Identifier: iMac14,4
      Processor Name: Intel Core i5
      Processor Speed: 1.4 GHz
      Number of Processors: 1
      Total Number of Cores: 2
      L2 Cache (per Core): 256 KB
      L3 Cache: 3 MB
      Hyper-Threading Technology: Enabled
      Memory: 8 GB
      Boot ROM Version: 199.0.0.0.0
      SMC Version (system): 2.21f92

Software:

    System Software Overview:

      System Version: macOS 10.14.6 (18G103)
      Kernel Version: Darwin 18.7.0
      Time since boot: 5 days 4:05

Graphics/Displays:

    Intel HD Graphics 5000:

      Chipset Model: Intel HD Graphics 5000
      Type: GPU
      Bus: Built-In
      VRAM (Dynamic, Max): 1536 MB
      Vendor: Intel
      Device ID: 0x0a26
      Revision ID: 0x0009
      Metal: Supported, feature set macOS GPUFamily1 v4
      Displays:
        iMac:
          Display Type: LCD
          Resolution: 1920 x 1080 (1080p FHD - Full High Definition)
          UI Looks like: 1920 x 1080
          Framebuffer Depth: 24-Bit Color (ARGB8888)
          Main Display: Yes
          Mirror: Off
          Online: Yes
          Rotation: Supported
          Automatically Adjust Brightness: No
          Connection Type: DisplayPort

Locale: (None, 'UTF-8')
PyQt5 5.15.2, Qt 5.15.2
Installed Packages:
    alabaster: 0.7.12
    appdirs: 1.4.4
    appnope: 0.1.2
    Babel: 2.9.1
    backcall: 0.2.0
    blockdiag: 2.0.1
    certifi: 2020.12.5
    cftime: 1.5.0
    chardet: 3.0.4
    ChimeraX-AddCharge: 1.0.1
    ChimeraX-AddH: 2.1.6
    ChimeraX-AlignmentAlgorithms: 2.0
    ChimeraX-AlignmentHdrs: 3.2
    ChimeraX-AlignmentMatrices: 2.0
    ChimeraX-Alignments: 2.1
    ChimeraX-AmberInfo: 1.0
    ChimeraX-Arrays: 1.0
    ChimeraX-Atomic: 1.13.2
    ChimeraX-AtomicLibrary: 3.1.3
    ChimeraX-AtomSearch: 2.0
    ChimeraX-AtomSearchLibrary: 1.0
    ChimeraX-AxesPlanes: 2.0
    ChimeraX-BasicActions: 1.1
    ChimeraX-BILD: 1.0
    ChimeraX-BlastProtein: 1.1
    ChimeraX-BondRot: 2.0
    ChimeraX-BugReporter: 1.0
    ChimeraX-BuildStructure: 2.5.2
    ChimeraX-Bumps: 1.0
    ChimeraX-BundleBuilder: 1.1
    ChimeraX-ButtonPanel: 1.0
    ChimeraX-CageBuilder: 1.0
    ChimeraX-CellPack: 1.0
    ChimeraX-Centroids: 1.1
    ChimeraX-ChemGroup: 2.0
    ChimeraX-Clashes: 2.1
    ChimeraX-Clipper: 0.16.1
    ChimeraX-ColorActions: 1.0
    ChimeraX-ColorGlobe: 1.0
    ChimeraX-ColorKey: 1.2.1
    ChimeraX-CommandLine: 1.1.4
    ChimeraX-ConnectStructure: 2.0
    ChimeraX-Contacts: 1.0
    ChimeraX-Core: 1.2.5
    ChimeraX-CoreFormats: 1.0
    ChimeraX-coulombic: 1.1.1
    ChimeraX-Crosslinks: 1.0
    ChimeraX-Crystal: 1.0
    ChimeraX-CrystalContacts: 1.0
    ChimeraX-DataFormats: 1.1
    ChimeraX-Dicom: 1.0
    ChimeraX-DistMonitor: 1.1.3
    ChimeraX-DistUI: 1.0
    ChimeraX-Dssp: 2.0
    ChimeraX-EMDB-SFF: 1.0
    ChimeraX-ExperimentalCommands: 1.0
    ChimeraX-FileHistory: 1.0
    ChimeraX-FunctionKey: 1.0
    ChimeraX-Geometry: 1.1
    ChimeraX-gltf: 1.0
    ChimeraX-Graphics: 1.0
    ChimeraX-Hbonds: 2.1
    ChimeraX-Help: 1.1
    ChimeraX-HKCage: 1.3
    ChimeraX-IHM: 1.0
    ChimeraX-ImageFormats: 1.1
    ChimeraX-IMOD: 1.0
    ChimeraX-IO: 1.0.1
    ChimeraX-ISOLDE: 1.2.2
    ChimeraX-Label: 1.0
    ChimeraX-ListInfo: 1.1.1
    ChimeraX-Log: 1.1.2
    ChimeraX-LookingGlass: 1.1
    ChimeraX-Maestro: 1.8.1
    ChimeraX-Map: 1.0.2
    ChimeraX-MapData: 2.0
    ChimeraX-MapEraser: 1.0
    ChimeraX-MapFilter: 2.0
    ChimeraX-MapFit: 2.0
    ChimeraX-MapSeries: 2.0
    ChimeraX-Markers: 1.0
    ChimeraX-Mask: 1.0
    ChimeraX-MatchMaker: 1.2.1
    ChimeraX-MDcrds: 2.2
    ChimeraX-MedicalToolbar: 1.0.1
    ChimeraX-Meeting: 1.0
    ChimeraX-MLP: 1.1
    ChimeraX-mmCIF: 2.3
    ChimeraX-MMTF: 2.1
    ChimeraX-Modeller: 1.0.1
    ChimeraX-ModelPanel: 1.0.1
    ChimeraX-ModelSeries: 1.0
    ChimeraX-Mol2: 2.0
    ChimeraX-Morph: 1.0
    ChimeraX-MouseModes: 1.1
    ChimeraX-Movie: 1.0
    ChimeraX-Neuron: 1.0
    ChimeraX-Nucleotides: 2.0.1
    ChimeraX-OpenCommand: 1.5
    ChimeraX-PDB: 2.4.1
    ChimeraX-PDBBio: 1.0
    ChimeraX-PDBLibrary: 1.0.1
    ChimeraX-PDBMatrices: 1.0
    ChimeraX-PickBlobs: 1.0
    ChimeraX-Positions: 1.0
    ChimeraX-PresetMgr: 1.0.1
    ChimeraX-PubChem: 2.0.1
    ChimeraX-ReadPbonds: 1.0
    ChimeraX-Registration: 1.1
    ChimeraX-RemoteControl: 1.0
    ChimeraX-ResidueFit: 1.0
    ChimeraX-RestServer: 1.1
    ChimeraX-RNALayout: 1.0
    ChimeraX-RotamerLibMgr: 2.0
    ChimeraX-RotamerLibsDunbrack: 2.0
    ChimeraX-RotamerLibsDynameomics: 2.0
    ChimeraX-RotamerLibsRichardson: 2.0
    ChimeraX-SaveCommand: 1.4
    ChimeraX-SchemeMgr: 1.0
    ChimeraX-SDF: 2.0
    ChimeraX-Segger: 1.0
    ChimeraX-Segment: 1.0
    ChimeraX-SeqView: 2.3
    ChimeraX-Shape: 1.0.1
    ChimeraX-Shell: 1.0
    ChimeraX-Shortcuts: 1.0
    ChimeraX-ShowAttr: 1.0
    ChimeraX-ShowSequences: 1.0
    ChimeraX-SideView: 1.0
    ChimeraX-Smiles: 2.0.1
    ChimeraX-SmoothLines: 1.0
    ChimeraX-SpaceNavigator: 1.0
    ChimeraX-StdCommands: 1.3.1
    ChimeraX-STL: 1.0
    ChimeraX-Storm: 1.0
    ChimeraX-Struts: 1.0
    ChimeraX-Surface: 1.0
    ChimeraX-SwapAA: 2.0
    ChimeraX-SwapRes: 2.1
    ChimeraX-TapeMeasure: 1.0
    ChimeraX-Test: 1.0
    ChimeraX-Toolbar: 1.0.1
    ChimeraX-ToolshedUtils: 1.2
    ChimeraX-Tug: 1.0
    ChimeraX-UI: 1.7.6
    ChimeraX-uniprot: 2.1
    ChimeraX-UnitCell: 1.0
    ChimeraX-ViewDockX: 1.0
    ChimeraX-Vive: 1.1
    ChimeraX-VolumeMenu: 1.0
    ChimeraX-VTK: 1.0
    ChimeraX-WavefrontOBJ: 1.0
    ChimeraX-WebCam: 1.0
    ChimeraX-WebServices: 1.0
    ChimeraX-Zone: 1.0
    colorama: 0.4.3
    comtypes: 1.1.7
    cxservices: 1.0
    cycler: 0.10.0
    Cython: 0.29.21
    decorator: 5.0.9
    distlib: 0.3.1
    docutils: 0.16
    filelock: 3.0.12
    funcparserlib: 0.3.6
    grako: 3.16.5
    h5py: 2.10.0
    html2text: 2020.1.16
    idna: 2.10
    ihm: 0.17
    imagecodecs: 2020.5.30
    imagesize: 1.2.0
    ipykernel: 5.3.4
    ipython: 7.18.1
    ipython-genutils: 0.2.0
    jedi: 0.17.2
    Jinja2: 2.11.2
    jupyter-client: 6.1.7
    jupyter-core: 4.7.1
    kiwisolver: 1.3.1
    line-profiler: 2.1.2
    lxml: 4.6.2
    lz4: 3.1.0
    MarkupSafe: 2.0.1
    matplotlib: 3.3.2
    matplotlib-inline: 0.1.2
    msgpack: 1.0.0
    netCDF4: 1.5.4
    networkx: 2.5
    numexpr: 2.7.3
    numpy: 1.19.2
    numpydoc: 1.1.0
    openvr: 1.14.1501
    packaging: 20.9
    ParmEd: 3.2.0
    parso: 0.7.1
    pexpect: 4.8.0
    pickleshare: 0.7.5
    Pillow: 7.2.0
    pip: 21.0.1
    pkginfo: 1.5.0.1
    prompt-toolkit: 3.0.18
    psutil: 5.7.2
    ptyprocess: 0.7.0
    pycollada: 0.7.1
    pydicom: 2.0.0
    Pygments: 2.7.1
    PyOpenGL: 3.1.5
    PyOpenGL-accelerate: 3.1.5
    pyparsing: 2.4.7
    PyQt5-commercial: 5.15.2
    PyQt5-sip: 12.8.1
    PyQtWebEngine-commercial: 5.15.2
    python-dateutil: 2.8.1
    pytz: 2021.1
    pyzmq: 22.0.3
    qtconsole: 4.7.7
    QtPy: 1.9.0
    RandomWords: 0.3.0
    requests: 2.24.0
    scipy: 1.5.2
    setuptools: 50.3.2
    sfftk-rw: 0.6.7.dev1
    six: 1.15.0
    snowballstemmer: 2.1.0
    sortedcontainers: 2.2.2
    Sphinx: 3.2.1
    sphinxcontrib-applehelp: 1.0.2
    sphinxcontrib-blockdiag: 2.0.0
    sphinxcontrib-devhelp: 1.0.2
    sphinxcontrib-htmlhelp: 2.0.0
    sphinxcontrib-jsmath: 1.0.1
    sphinxcontrib-qthelp: 1.0.3
    sphinxcontrib-serializinghtml: 1.1.5
    suds-jurko: 0.6
    tables: 3.6.1
    tifffile: 2020.9.3
    tinyarray: 1.2.3
    tornado: 6.1
    traitlets: 5.0.5
    urllib3: 1.25.11
    wcwidth: 0.2.5
    webcolors: 1.11.1
    wheel: 0.36.0
    wheel-filename: 1.3.0

Change History (2)

comment:1 by Eric Pettersen, 3 years ago

Component: UnassignedThird Party
Description: modified (diff)
Owner: set to Tristan Croll
Platform: all
Project: ChimeraX
Status: newassigned
Summary: ChimeraX bug report submissionFlip peptide bond: wrapped C/C++ object of type QTableWidget has been deleted

Reported by Henry Shuman

comment:2 by Tristan Croll, 3 years ago

Resolution: fixed
Status: assignedclosed

Totally rebuilt GUI as of 1.4, taking care of this bug amongst others.

Note: See TracTickets for help on using tickets.