#1873 closed defect (fixed)

Volume series surface disappears when histogram threshold moved

Reported by: Tom Goddard Owned by: Tom Goddard
Priority: moderate Milestone:
Component: Volume Data Version:
Keywords: Cc:
Blocked By: Blocking:
Notify when closed: Platform: all
Project: ChimeraX

Description

Saw in today's 3d microscopy workshop at Parnassus that after changing the time slider for a volume series and moving the histogram surface threshold the surface vanishes.

Change History (1)

comment:1 by Tom Goddard, 7 years ago

Resolution: fixed
Status: assignedclosed

Fixed.

Problem was the volume surface associated with each histogram marker was not being updated when the volume series time changed.