Opened 2 years ago

Closed 2 years ago

#9397 closed defect (fixed)

Segmentations (SEG) models should not appear in choices of medical-image models to segment

Reported by: Elaine Meng Owned by: Zach Pearson
Priority: moderate Milestone:
Component: DICOM Version:
Keywords: Cc:
Blocked By: Blocking:
Notify when closed: Platform: all
Project: ChimeraX

Description

SEG models should be suppressed from the Segmentations dialog "Models" list of medical-image data to segment. Unless you have a reason or use case to include them. As far as I can tell, including them doesn't make sense because their slice views just solid color anyway.

A related (converse) suggestion was that SEG models opened from file should appear in the segmentations list in the Segmentations tool. Will let you decide whether to make a separate ticket for that or not.

Change History (6)

comment:1 by Zach Pearson, 2 years ago

Resolution: fixed
Status: assignedclosed

comment:2 by Zach Pearson, 2 years ago

#9419 has the second request.

comment:3 by Elaine Meng, 2 years ago

Resolution: fixed
Status: closedreopened

not fixed: I just opened a DICOM with CT + SEG and all the SEG models were still listed in the menu of models to segment in the Segmentations tool.
UCSF ChimeraX version: 1.7.dev202307260053 (2023-07-26)

comment:4 by Zach Pearson, 2 years ago

Darn, OK -- on it.

comment:6 by Zach Pearson, 2 years ago

Resolution: fixed
Status: reopenedclosed
Note: See TracTickets for help on using tickets.