#7033 closed defect (can't reproduce)
Crash using File→Open on Windows and/or in return statement
Reported by: | Owned by: | pett | |
---|---|---|---|
Priority: | normal | Milestone: | |
Component: | Platform | Version: | |
Keywords: | Cc: | Tom Goddard | |
Blocked By: | Blocking: | ||
Notify when closed: | Platform: | all | |
Project: | ChimeraX |
Description (last modified by )
The following bug report has been submitted: Platform: Windows-10-10.0.19044 ChimeraX Version: 1.3 (2021-12-08 23:08:33 UTC) Description Last time you used ChimeraX it crashed. Please describe steps that led to the crash here. I tried to load a complex of a receptor protein docked to a ligand from a SwissDock output which I previously exported as a PDB combined data file to another ChimeraX 1.3 project. No idea why it just crashed but it does this reproducibly on my Windows 10 / AMD 290X MXI Lightning graphics system. The same happens when the receptor protein from the SwissDock raw output plus the clusters.dock4.pdb is sequentially loaded and then the ChimeraX output quality is set to "full": same crash. Windows fatal exception: access violation Current thread 0x0000132c (most recent call first): File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\ui\gui.py", line 301 in event_loop File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\ChimeraX_main.py", line 867 in init File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\ChimeraX_main.py", line 1018 in File "C:\Program Files\ChimeraX 1.3\bin\lib\runpy.py", line 87 in _run_code File "C:\Program Files\ChimeraX 1.3\bin\lib\runpy.py", line 197 in _run_module_as_main Windows fatal exception: code 0x8001010e Thread 0x00001188 (most recent call first): File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 316 in wait File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 574 in wait File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 1284 in run File "C:\Program Files\ChimeraX 1.3\Windows fatal exception: bcode 0xi8001010en \lWindows fatal exception: icode 0xb8001010e\ thWindows fatal exception: rcode 0xe8001010ea diWindows fatal exception: ncode 0xg8001010e. pyWindows fatal exception: "code 0x, line 8001010e973 in _Windows fatal exception: bcode 0xo8001010eo tsWindows fatal exception: tcode 0xr8001010ea p_Windows fatal exception: icode 0xn8001010en erWindows fatal exception: code 0x File 8001010e" CWindows fatal exception: :code 0x\8001010eP rogram Files\ChimeraX 1.3\bin\lib\threading.py", line 930 in _bootstrap Thread 0x00001438 (most recent call first): File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\open_command\dialoWindows fatal exception: gcode 0x.8001010ep y"Windows fatal exception: , line code 0x1358001010e in sWindows fatal exception: hcode 0xo8001010ew _Windows fatal exception: ocode 0xp8001010ee nWindows fatal exception: _code 0xf8001010eile_dialog File Windows fatal exception: "code 0xC8001010e: \PWindows fatal exception: rcode 0xo8001010eg raWindows fatal exception: mcode 0x 8001010eF iWindows fatal exception: lcode 0xe8001010es \Windows fatal exception: Ccode 0xh8001010ei meraX 1.3\bWindows fatal exception: icode 0xn8001010e\ liWindows fatal exception: bcode 0x\8001010es itWindows fatal exception: ecode 0x-8001010ep aWindows fatal exception: ccode 0xk8001010ea Windows fatal exception: code 0x8001010e Windows fatal exception: code 0xg8001010ee s\Windows fatal exception: chcode 0x8001010e Windows fatal exception: code 0xWindows fatal exception: 8001010ecode 0x 8001010e Windows fatal exception: code 0xWindows fatal exception: 8001010ecode 0x 8001010e Windows fatal exception: Windows fatal exception: code 0xcode 0x8001010e8001010e Windows fatal exception: icode 0xm8001010ee rWindows fatal exception: acode 0xx8001010e\ tWindows fatal exception: ocode 0xolbar\provid8001010e eWindows fatal exception: rcode 0xs8001010e. pWindows fatal exception: ycode 0x"8001010e, line 17Windows fatal exception: in code 0x_8001010ef iWindows fatal exception: lcode 0x8001010e e_open File "C:\PrWindows fatal exception: ocode 0xg8001010er amWindows fatal exception: code 0xF8001010ei lWindows fatal exception: ecode 0xs8001010e\ CWindows fatal exception: hcode 0xi8001010em erWindows fatal exception: acode 0xX8001010e 1.Windows fatal exception: 3code 0x\8001010eb iWindows fatal exception: ncode 0x\8001010el iWindows fatal exception: bcode 0x\8001010es iWindows fatal exception: tcode 0xe8001010e- pWindows fatal exception: acode 0xc8001010ek ages\chimerax\toolbar\providers.py", line 45 in run_provider File "C:\Program FiWindows fatal exception: lcode 0xe8001010es \CWindows fatal exception: hcode 0xi8001010em erWindows fatal exception: acode 0xX8001010e 1Windows fatal exception: .code 0x38001010e\ biWindows fatal exception: ncode 0x\8001010el ibWindows fatal exception: \code 0xs8001010ei teWindows fatal exception: -code 0xp8001010ea cWindows fatal exception: kcode 0xa8001010eg eWindows fatal exception: scode 0x\8001010ec hWindows fatal exception: icode 0xm8001010ee rax\toolbar\__init__.py", line 37 in run_provider File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\core\toolshed\__init__.py", line 1284 in run_provider File "C:\Program FileWindows fatal exception: code 0xs8001010e\ ChWindows fatal exception: icode 0xm8001010ee raWindows fatal exception: Xcode 0x 8001010e1 .Windows fatal exception: 3code 0x\8001010eb iWindows fatal exception: ncode 0x\8001010el iWindows fatal exception: bcode 0x\8001010es iWindows fatal exception: tcode 0xe8001010e- pWindows fatal exception: acode 0xc8001010ek aWindows fatal exception: gcode 0xe8001010es \Windows fatal exception: ccode 0xh8001010ei merax\core\toolshed\info.py", line 381 in run_provider File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\toolbar\tool.py", line 165 in callback File "C:\Program Files\ChimeraX 1.Windows fatal exception: 3code 0x\8001010eb inWindows fatal exception: \code 0xl8001010ei b\Windows fatal exception: scode 0xi8001010et eWindows fatal exception: -code 0xp8001010ea ckWindows fatal exception: acode 0xg8001010ee s\Windows fatal exception: ccode 0xh8001010ei meWindows fatal exception: rcode 0xa8001010ex \Windows fatal exception: ucode 0xi8001010e\ gWindows fatal exception: ucode 0xi8001010e. pWindows fatal exception: ycode 0x"8001010e, line 301 in event_loop File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\ChimeraX_main.py", line 867 in init File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\ChimeraX_main.py", line 1018 in File "C:\Program Files\ChimeraX 1.3\bin\lib\runpy.py", line 87 in _run_code File "C:\Program Files\ChimeraX 1.3\bin\lib\runpy.py", line 197 in _run_module_as_main Windows fatal exception: code 0x8001010e Thread 0x00001188 (most recent call first): File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 316 in wait File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 574 in wait File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 1284 in run File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 973 in _bootstrap_inner File "C:\Program Files\ChimeraX 1.3\bin\lib\threaWindows fatal exception: code 0xd8001010ei ngWindows fatal exception: .code 0xp8001010ey ", line Windows fatal exception: 930code 0x in 8001010e_ boWindows fatal exception: code 0x8001010e otWindows fatal exception: scode 0xt8001010er apWindows fatal exception: code 0x 8001010eThread 0x 00001438 (most recent call first): Windows fatal exception: File code 0x"8001010eC :Windows fatal exception: \code 0xP8001010er oWindows fatal exception: gcode 0xr8001010ea mWindows fatal exception: code 0xF8001010ei les\ChimeraX 1.3\bin\lib\site-pacWindows fatal exception: code 0xk8001010ea geWindows fatal exception: scode 0x\8001010ec hiWindows fatal exception: mcode 0xe8001010er aWindows fatal exception: xcode 0x\8001010eo pWindows fatal exception: ecode 0xn8001010e_ cWindows fatal exception: ocode 0xm8001010em aWindows fatal exception: ncode 0xd8001010e\ dWindows fatal exception: icode 0xa8001010el oWindows fatal exception: gcode 0x.8001010ep yWindows fatal exception: "code 0x, line 8001010e135 in sWindows fatal exception: code 0x8001010e hWindows fatal exception: ocode 0xw8001010e_ opWindows fatal exception: ecode 0xn8001010e_ fWindows fatal exception: icode 0xl8001010ee _Windows fatal exception: dcode 0xi8001010ea lWindows fatal exception: ocode 0xg8001010e File Windows fatal exception: "code 0xC8001010e: \Windows fatal exception: Pcode 0x8001010er oWindows fatal exception: gcode 0xr8001010ea Windows fatal exception: Windows fatal exception: mcode 0xcode 0x8001010e8001010e Windows fatal exception: Fcode 0xi8001010el esWindows fatal exception: \code 0xC8001010eh iWindows fatal exception: mcode 0xe8001010er aWindows fatal exception: Xcode 0x 8001010e1 .Windows fatal exception: 3code 0x\8001010eb Windows fatal exception: in\lib\code 0xs8001010ei te-Windows fatal exception: pcode 0xa8001010ec kaWindows fatal exception: gcode 0xWindows fatal exception: 8001010ecode 0xe8001010e sWindows fatal exception: \code 0xWindows fatal exception: 8001010ecode 0xc8001010e hWindows fatal exception: icode 0xm8001010ee rWindows fatal exception: acode 0xx8001010e\ tWindows fatal exception: ocode 0xo8001010el bWindows fatal exception: acode 0xr8001010e\ pWindows fatal exception: rcode 0xo8001010ev iWindows fatal exception: dcode 0xe8001010er sWindows fatal exception: .code 0xp8001010eWindows fatal exception: code 0x8001010e yWindows fatal exception: code 0x"8001010e, line Windows fatal exception: 17code 0x in 8001010e_ file _Windows fatal exception: ocode 0xp8001010ee nWindows fatal exception: code 0x File 8001010e" CWindows fatal exception: :code 0x8001010e Windows fatal exception: code 0x\8001010eP rWindows fatal exception: ocode 0xg8001010er aWindows fatal exception: mcode 0x 8001010eFWindows fatal exception: icode 0xl8001010e eWindows fatal exception: scode 0xWindows fatal exception: 8001010e\ Ccode 0xWindows fatal exception: 8001010eh icode 0xWindows fatal exception: 8001010em ecode 0xr8001010ea XWindows fatal exception: code 0x18001010e. 3Windows fatal exception: \code 0xb8001010ei nWindows fatal exception: \code 0xl8001010ei bWindows fatal exception: \code 0xs8001010ei tWindows fatal exception: ecode 0x-8001010ep aWindows fatal exception: ccode 0xk8001010ea gWindows fatal exception: ecode 0xs8001010e\ chimerax\toolbar\providers.py", line 45 in run_provider File "CWindows fatal exception: code 0x:8001010e\ PrWindows fatal exception: ocode 0xg8001010er amWindows fatal exception: code 0x8001010e Windows fatal exception: code 0x8001010e Windows fatal exception: Fcode 0xi8001010el eWindows fatal exception: scode 0x\8001010eC hWindows fatal exception: icode 0xm8001010ee rWindows fatal exception: acode 0xX8001010e 1Windows fatal exception: .code 0x38001010e\Windows fatal exception: bcode 0xi8001010e nWindows fatal exception: \code 0xWindows fatal exception: 8001010ecode 0xl8001010e ibWindows fatal exception: \code 0xs8001010ei tWindows fatal exception: ecode 0x-8001010ep aWindows fatal exception: ccode 0xk8001010ea gWindows fatal exception: ecode 0xs8001010e\ cWindows fatal exception: hcode 0xi8001010em eWindows fatal exception: rcode 0xa8001010ex \Windows fatal exception: tcode 0xoWindows fatal exception: code 0x8001010e8001010e oWindows fatal exception: lcode 0xWindows fatal exception: 8001010ecode 0x 8001010ebWindows fatal exception: a rcode 0x\8001010e_ _iWindows fatal exception: ncode 0xi8001010et _Windows fatal exception: _code 0x.8001010ep yWindows fatal exception: "code 0x, line 8001010e37 in Windows fatal exception: rcode 0xu8001010en _Windows fatal exception: pcode 0xWindows fatal exception: 8001010ecode 0xr8001010eo v Windows fatal exception: Windows fatal exception: code 0xcode 0x8001010e8001010ei dWindows fatal exception: ecode 0x 8001010erWindows fatal exception: code 0x File 8001010e" C :\Windows fatal exception: Pcode 0xr8001010eo gWindows fatal exception: rcode 0xa8001010em Windows fatal exception: Fcode 0xi8001010el eWindows fatal exception: scode 0x\8001010eC hWindows fatal exception: code 0xWindows fatal exception: 8001010ecode 0x 8001010ei Windows fatal exception: code 0xWindows fatal exception: 8001010ecode 0xm8001010e eWindows fatal exception: Windows fatal exception: code 0xr8001010ea X code 0x8001010e 1Windows fatal exception: .code 0x38001010e\ biWindows fatal exception: ncode 0x\8001010el iWindows fatal exception: bcode 0x\Windows fatal exception: s8001010ei tWindows fatal exception: ecode 0x-code 0xp8001010ea 8001010eWindows fatal exception: ckWindows fatal exception: acode 0xcode 0x8001010e8001010e gWindows fatal exception: ecode 0xsWindows fatal exception: \code 0xc8001010eh i8001010em erWindows fatal exception: acode 0xWindows fatal exception: 8001010ex \code 0xc8001010eo reWindows fatal exception: \code 0xtWindows fatal exception: o8001010eocode 0xl s8001010eWindows fatal exception: code 0xhWindows fatal exception: e8001010edcode 0x\ _8001010eWindows fatal exception: code 0x_Windows fatal exception: i8001010en iWindows fatal exception: tcode 0x_8001010ecode 0x8001010e _Windows fatal exception: code 0x.Windows fatal exception: pcode 0x8001010e8001010e yWindows fatal exception: "code 0x 8001010e, line 1284Windows fatal exception: in code 0xrWindows fatal exception: u8001010encode 0x 8001010e_ pWindows fatal exception: rcode 0xo8001010ev Windows fatal exception: Windows fatal exception: code 0xi8001010ed ecode 0xr8001010eWindows fatal exception: code 0x Windows fatal exception: File code 0x8001010e8001010e" C :Windows fatal exception: \Windows fatal exception: code 0xcode 0x8001010e8001010e PWindows fatal exception: rcode 0xo8001010eg rWindows fatal exception: acode 0xm8001010e FWindows fatal exception: icode 0xl8001010ee sWindows fatal exception: \code 0xC8001010eh iWindows fatal exception: mcode 0xe8001010er aWindows fatal exception: Xcode 0x 8001010e1 .Windows fatal exception: 3code 0x\8001010eb Windows fatal exception: code 0xi8001010en \lWindows fatal exception: icode 0xb8001010e\ siWindows fatal exception: tcode 0xe8001010e- pWindows fatal exception: acode 0xc8001010ek aWindows fatal exception: gcode 0xe8001010es \Windows fatal exception: ccode 0xh8001010ei mWindows fatal exception: ecode 0xr8001010ea xWindows fatal exception: \code 0xc8001010eo rWindows fatal exception: ecode 0x\8001010et oWindows fatal exception: ocode 0xl8001010es hed\info.py", line 381 in run_provider File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\toolbar\tool.py", line 165 in callback File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\ui\gui.py", line 301 in event_loop File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\ChimeraX_main.py", line 867 in init File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\ChimeraX_main.py", line 1018 in File "C:\Program Files\ChimeraX 1.3\bin\lib\runpy.py", line 87 in _run_code File "C:\Program Files\ChimeraX 1.3\bin\lib\runpy.py", line 197 in _run_module_as_main Windows fatal exception: code 0x8001010e Thread 0x00001188 (most recent call first): File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 316 in wait File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 574 in wait File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 1284 in run File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 973 in _bootstrap_inner File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 930 in _bootstrap Thread 0x00001438 (most recent call first): File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\open_command\dialog.py", line 135 in show_open_file_dialog File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\toolbar\providers.py", line 17 in _file_open File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\toolbar\providers.py", line 45 in run_provider File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\toolbar\__init__.py", line 37 in run_provider File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\core\toolshed\__init__.py", line 1284 in run_provider File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\core\toolshed\info.py", line 381 in run_provider File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\toolbar\tool.py", line 165 in callback File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\ui\gui.py", line 301 in event_loop File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\ChimeraX_main.py", line 867 in init File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\ChimeraX_main.py", line 1018 in File "C:\Program Files\ChimeraX 1.3\bin\lib\runpy.py", line 87 in _run_code File "C:\Program Files\ChimeraX 1.3\bin\lib\runpy.py", line 197 in _run_module_as_main Windows fatal exception: code 0x8001010e Thread 0x00001188 (most recent call first): File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 316 in wait File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 574 in wait File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 1284 in run File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 973 in _bootstrap_inner File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 930 in _bootstrap Thread 0x00001438 (most recent call first): File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\open_command\dialog.py", line 135 in show_open_file_dialog File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\toolbar\providers.py", line 17 in _file_open File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\toolbar\providers.py", line 45 in run_provider File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\toolbar\__init__.py", line 37 in run_provider File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\core\toolshed\__init__.py", line 1284 in run_provider File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\core\toolshed\info.py", line 381 in run_provider File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\toolbar\tool.py", line 165 in callback File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\ui\gui.py", line 301 in event_loop File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\ChimeraX_main.py", line 867 in init File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\ChimeraX_main.py", line 1018 in File "C:\Program Files\ChimeraX 1.3\bin\lib\runpy.py", line 87 in _run_code File "C:\Program Files\ChimeraX 1.3\bin\lib\runpy.py", line 197 in _run_module_as_main Windows fatal exception: code 0x8001010e Thread 0x00001188 (most recent call first): File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 316 in wait File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 574 in wait File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 1284 in run File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 973 in _bootstrap_inner File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 930 in _bootstrap Thread 0x00001438 (most recent call first): File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\open_command\dialog.py", line 135 in show_open_file_dialog File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\toolbar\providers.py", line 17 in _file_open File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\toolbar\providers.py", line 45 in run_provider File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\toolbar\__init__.py", line 37 in run_provider File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\core\toolshed\__init__.py", line 1284 in run_provider File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\core\toolshed\info.py", line 381 in run_provider File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\toolbar\tool.py", line 165 in callback File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\ui\gui.py", line 301 in event_loop File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\ChimeraX_main.py", line 867 in init File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\ChimeraX_main.py", line 1018 in File "C:\Program Files\ChimeraX 1.3\bin\lib\runpy.py", line 87 in _run_code File "C:\Program Files\ChimeraX 1.3\bin\lib\runpy.py", line 197 in _run_module_as_main Windows fatal exception: code 0x8001010e Thread 0x00001188 (most recent call first): File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 316 in wait File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 574 in wait File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 1284 in run File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 973 in _bootstrap_inner File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 930 in _bootstrap Thread 0x00001438 (most recent call first): File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\open_command\dialog.py", line 135 in show_open_file_dialog File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\toolbar\providers.py", line 17 in _file_open File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\toolbar\providers.py", line 45 in run_provider File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\toolbar\__init__.py", line 37 in run_provider File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\core\toolshed\__init__.py", line 1284 in run_provider File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\core\toolshed\info.py", line 381 in run_provider File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\toolbar\tool.py", line 165 in callback File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\ui\gui.py", line 301 in event_loop File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\ChimeraX_main.py", line 867 in init File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\ChimeraX_main.py", line 1018 in File "C:\Program Files\ChimeraX 1.3\bin\lib\runpy.py", line 87 in _run_code File "C:\Program Files\ChimeraX 1.3\bin\lib\runpy.py", line 197 in _run_module_as_main Windows fatal exception: code 0x8001010e Thread 0x00001188 (most recent call first): File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 316 in wait File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 574 in wait File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 1284 in run File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 973 in _bootstrap_inner File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 930 in _bootstrap Thread 0x00001438 (most recent call first): File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\open_command\dialog.py", line 135 in show_open_file_dialog File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\toolbar\providers.py", line 17 in _file_open File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\toolbar\providers.py", line 45 in run_provider File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\toolbar\__init__.py", line 37 in run_provider File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\core\toolshed\__init__.py", line 1284 in run_provider File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\core\toolshed\info.py", line 381 in run_provider File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\toolbar\tool.py", line 165 in callback File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\ui\gui.py", line 301 in event_loop File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\ChimeraX_main.py", line 867 in init File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\ChimeraX_main.py", line 1018 in File "C:\Program Files\ChimeraX 1.3\bin\lib\runpy.py", line 87 in _run_code File "C:\Program Files\ChimeraX 1.3\bin\lib\runpy.py", line 197 in _run_module_as_main Windows fatal exception: code 0x8001010e Thread 0x00001188 (most recent call first): File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 316 in wait File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 574 in wait File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 1284 in run File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 973 in _bootstrap_inner File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 930 in _bootstrap Thread 0x00001438 (most recent call first): File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\open_command\dialog.py", line 135 in show_open_file_dialog File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\toolbar\providers.py", line 17 in _file_open File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\toolbar\providers.py", line 45 in run_provider File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\toolbar\__init__.py", line 37 in run_provider File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\core\toolshed\__init__.py", line 1284 in run_provider File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\core\toolshed\info.py", line 381 in run_provider File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\toolbar\tool.py", line 165 in callback File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\chimerax\ui\gui.py", line 301 in event_loop File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\ChimeraX_main.py", line 867 in init File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\ChimeraX_main.py", line 1018 in File "C:\Program Files\ChimeraX 1.3\bin\lib\runpy.py", line 87 in _run_code File "C:\Program Files\ChimeraX 1.3\bin\lib\runpy.py", line 197 in _run_module_as_main Windows fatal exception: code 0x8001010e Thread 0x00001188 (most recent call first): File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 316 in wait File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 574 in wait File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 1284 in run File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 973 in _bootstrap_inner File "C:\Program Files\ChimeraX 1.3\bin\lib\threading.py", line 930 in _bootstrap Thread 0x00001438 (most recent call first): File "C:\Program Files\ChimeraX 1.3\bin\lib\site-packages\numpy\core\_methods.py", line 57 in _any Windows fatal exception: access violation ===== Log before crash start ===== UCSF ChimeraX version: 1.3 (2021-12-08) © 2016-2021 Regents of the University of California. All rights reserved. How to cite UCSF ChimeraX > open C:\\\MW\\\add- > on\\\\_work\\\312er_Disulfiram_PubChem_swissdockd_SfO0bT_7M6GPQ99JZEF6HHA5R4G\\\target.pdb Summary of feedback from opening C:\\\MW\\\add- on\\\\_work\\\312er_Disulfiram_PubChem_swissdockd_SfO0bT_7M6GPQ99JZEF6HHA5R4G\\\target.pdb --- warnings | Ignored bad PDB record found on line 1 REMARK PYCHARMM CRD Ignored bad PDB record found on line 2 REMARK DATE: 12/ 9/21 13:35:21 CREATED BY USER: swissdock Chain information for target.pdb #1 --- Chain | Description ? | No description available > hide atoms > color dark gray > open C:/MW/add- > on/_work/312er_Disulfiram_PubChem_swissdockd_SfO0bT_7M6GPQ99JZEF6HHA5R4G/clusters.dock4.pdb Summary of feedback from opening C:/MW/add- on/_work/312er_Disulfiram_PubChem_swissdockd_SfO0bT_7M6GPQ99JZEF6HHA5R4G/clusters.dock4.pdb --- warnings | Ignored bad PDB record found on line 1 REMARK Energy: -44.1738 Ignored bad PDB record found on line 2 REMARK SimpleFitness: -44.1738 Ignored bad PDB record found on line 3 REMARK FullFitness: -1888.9918 Ignored bad PDB record found on line 4 REMARK InterFull: -46.1637 Ignored bad PDB record found on line 5 REMARK IntraFull: -21.4921 33 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 113 REMARK Energy: -40.0647 Ignored bad PDB record found on line 114 REMARK SimpleFitness: -40.0647 Ignored bad PDB record found on line 115 REMARK FullFitness: -1886.1324 Ignored bad PDB record found on line 116 REMARK InterFull: -41.8892 Ignored bad PDB record found on line 117 REMARK IntraFull: -18.7322 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 169 REMARK Energy: -38.7914 Ignored bad PDB record found on line 170 REMARK SimpleFitness: -38.7914 Ignored bad PDB record found on line 171 REMARK FullFitness: -1885.5642 Ignored bad PDB record found on line 172 REMARK InterFull: -41.1794 Ignored bad PDB record found on line 173 REMARK IntraFull: -18.6129 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 225 REMARK Energy: -37.9732 Ignored bad PDB record found on line 226 REMARK SimpleFitness: -37.9732 Ignored bad PDB record found on line 227 REMARK FullFitness: -1883.8562 Ignored bad PDB record found on line 228 REMARK InterFull: -42.7454 Ignored bad PDB record found on line 229 REMARK IntraFull: -17.0016 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 281 REMARK Energy: -36.971 Ignored bad PDB record found on line 282 REMARK SimpleFitness: -36.971 Ignored bad PDB record found on line 283 REMARK FullFitness: -1883.2208 Ignored bad PDB record found on line 284 REMARK InterFull: -43.5117 Ignored bad PDB record found on line 285 REMARK IntraFull: -17.8341 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 337 REMARK Energy: -33.7839 Ignored bad PDB record found on line 338 REMARK SimpleFitness: -33.7839 Ignored bad PDB record found on line 339 REMARK FullFitness: -1878.9155 Ignored bad PDB record found on line 340 REMARK InterFull: -39.5953 Ignored bad PDB record found on line 341 REMARK IntraFull: -15.3912 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 393 REMARK Energy: -23.6123 Ignored bad PDB record found on line 394 REMARK SimpleFitness: -23.6123 Ignored bad PDB record found on line 395 REMARK FullFitness: -1867.9635 Ignored bad PDB record found on line 396 REMARK InterFull: -36.5132 Ignored bad PDB record found on line 397 REMARK IntraFull: -7.66619 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 449 REMARK Energy: -36.9033 Ignored bad PDB record found on line 450 REMARK SimpleFitness: -36.9033 Ignored bad PDB record found on line 451 REMARK FullFitness: -1887.7617 Ignored bad PDB record found on line 452 REMARK InterFull: -27.5993 Ignored bad PDB record found on line 453 REMARK IntraFull: -24.3355 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 505 REMARK Energy: -33.9804 Ignored bad PDB record found on line 506 REMARK SimpleFitness: -33.9804 Ignored bad PDB record found on line 507 REMARK FullFitness: -1884.5424 Ignored bad PDB record found on line 508 REMARK InterFull: -23.2165 Ignored bad PDB record found on line 509 REMARK IntraFull: -25.7989 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 561 REMARK Energy: -30.5334 Ignored bad PDB record found on line 562 REMARK SimpleFitness: -30.5334 Ignored bad PDB record found on line 563 REMARK FullFitness: -1881.3698 Ignored bad PDB record found on line 564 REMARK InterFull: -21.6234 Ignored bad PDB record found on line 565 REMARK IntraFull: -25.4284 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 617 REMARK Energy: -25.7584 Ignored bad PDB record found on line 618 REMARK SimpleFitness: -25.7584 Ignored bad PDB record found on line 619 REMARK FullFitness: -1876.5366 Ignored bad PDB record found on line 620 REMARK InterFull: -19.2252 Ignored bad PDB record found on line 621 REMARK IntraFull: -19.9546 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 673 REMARK Energy: -25.2824 Ignored bad PDB record found on line 674 REMARK SimpleFitness: -25.2824 Ignored bad PDB record found on line 675 REMARK FullFitness: -1876.4951 Ignored bad PDB record found on line 676 REMARK InterFull: -17.5031 Ignored bad PDB record found on line 677 REMARK IntraFull: -21.6699 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 729 REMARK Energy: -23.6111 Ignored bad PDB record found on line 730 REMARK SimpleFitness: -23.6111 Ignored bad PDB record found on line 731 REMARK FullFitness: -1873.7529 Ignored bad PDB record found on line 732 REMARK InterFull: -15.5149 Ignored bad PDB record found on line 733 REMARK IntraFull: -21.343 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 785 REMARK Energy: -23.8541 Ignored bad PDB record found on line 786 REMARK SimpleFitness: -23.8541 Ignored bad PDB record found on line 787 REMARK FullFitness: -1873.7223 Ignored bad PDB record found on line 788 REMARK InterFull: -15.0601 Ignored bad PDB record found on line 789 REMARK IntraFull: -22.3403 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 841 REMARK Energy: -41.6616 Ignored bad PDB record found on line 842 REMARK SimpleFitness: -41.6616 Ignored bad PDB record found on line 843 REMARK FullFitness: -1887.217 Ignored bad PDB record found on line 844 REMARK InterFull: -38.1915 Ignored bad PDB record found on line 845 REMARK IntraFull: -22.7555 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 897 REMARK Energy: -41.6616 Ignored bad PDB record found on line 898 REMARK SimpleFitness: -41.6616 Ignored bad PDB record found on line 899 REMARK FullFitness: -1887.217 Ignored bad PDB record found on line 900 REMARK InterFull: -38.1915 Ignored bad PDB record found on line 901 REMARK IntraFull: -22.7555 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 953 REMARK Energy: -41.6627 Ignored bad PDB record found on line 954 REMARK SimpleFitness: -41.6627 Ignored bad PDB record found on line 955 REMARK FullFitness: -1887.2129 Ignored bad PDB record found on line 956 REMARK InterFull: -38.1931 Ignored bad PDB record found on line 957 REMARK IntraFull: -22.7498 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 1009 REMARK Energy: -41.6627 Ignored bad PDB record found on line 1010 REMARK SimpleFitness: -41.6627 Ignored bad PDB record found on line 1011 REMARK FullFitness: -1887.2129 Ignored bad PDB record found on line 1012 REMARK InterFull: -38.1931 Ignored bad PDB record found on line 1013 REMARK IntraFull: -22.7498 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 1065 REMARK Energy: -41.6627 Ignored bad PDB record found on line 1066 REMARK SimpleFitness: -41.6627 Ignored bad PDB record found on line 1067 REMARK FullFitness: -1887.2129 Ignored bad PDB record found on line 1068 REMARK InterFull: -38.1931 Ignored bad PDB record found on line 1069 REMARK IntraFull: -22.7498 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 1121 REMARK Energy: -41.6627 Ignored bad PDB record found on line 1122 REMARK SimpleFitness: -41.6627 Ignored bad PDB record found on line 1123 REMARK FullFitness: -1887.2129 Ignored bad PDB record found on line 1124 REMARK InterFull: -38.1931 Ignored bad PDB record found on line 1125 REMARK IntraFull: -22.7498 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 1177 REMARK Energy: -41.6627 Ignored bad PDB record found on line 1178 REMARK SimpleFitness: -41.6627 Ignored bad PDB record found on line 1179 REMARK FullFitness: -1887.2129 Ignored bad PDB record found on line 1180 REMARK InterFull: -38.1931 Ignored bad PDB record found on line 1181 REMARK IntraFull: -22.7498 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 1233 REMARK Energy: -41.6631 Ignored bad PDB record found on line 1234 REMARK SimpleFitness: -41.6631 Ignored bad PDB record found on line 1235 REMARK FullFitness: -1887.2078 Ignored bad PDB record found on line 1236 REMARK InterFull: -38.1786 Ignored bad PDB record found on line 1237 REMARK IntraFull: -22.7592 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 1289 REMARK Energy: -39.3433 Ignored bad PDB record found on line 1290 REMARK SimpleFitness: -39.3433 Ignored bad PDB record found on line 1291 REMARK FullFitness: -1885.5349 Ignored bad PDB record found on line 1292 REMARK InterFull: -42.186 Ignored bad PDB record found on line 1293 REMARK IntraFull: -19.9658 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 1345 REMARK Energy: -29.8274 Ignored bad PDB record found on line 1346 REMARK SimpleFitness: -29.8274 Ignored bad PDB record found on line 1347 REMARK FullFitness: -1876.2312 Ignored bad PDB record found on line 1348 REMARK InterFull: -34.0009 Ignored bad PDB record found on line 1349 REMARK IntraFull: -15.4002 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 1401 REMARK Energy: -29.5773 Ignored bad PDB record found on line 1402 REMARK SimpleFitness: -29.5773 Ignored bad PDB record found on line 1403 REMARK FullFitness: -1873.1396 Ignored bad PDB record found on line 1404 REMARK InterFull: -30.9701 Ignored bad PDB record found on line 1405 REMARK IntraFull: -15.7735 > matchmaker 3 to #1/A Missing or invalid "matchAtoms" argument: invalid atoms specifier > matchmaker 3 to #1 Missing or invalid "matchAtoms" argument: invalid atoms specifier ess: -1872.451 Ignored bad PDB record found on line 1460 REMARK InterFull: -25.3339 Ignored bad PDB record found on line 1461 REMARK IntraFull: -17.6441 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 1513 REMARK Energy: -25.6549 Ignored bad PDB record found on line 1514 REMARK SimpleFitness: -25.6549 Ignored bad PDB record found on line 1515 REMARK FullFitness: -1868.7015 Ignored bad PDB record found on line 1516 REMARK InterFull: -29.0461 Ignored bad PDB record found on line 1517 REMARK IntraFull: -11.2594 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 1569 REMARK Energy: -35.9026 Ignored bad PDB record found on line 1570 REMARK SimpleFitness: -35.9026 Ignored bad PDB record found on line 1571 REMARK FullFitness: -1885.3206 Ignored bad PDB record found on line 1572 REMARK InterFull: -29.5572 Ignored bad PDB record found on line 1573 REMARK IntraFull: -21.6003 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 1625 REMARK Energy: -35.9026 Ignored bad PDB record found on line 1626 REMARK SimpleFitness: -35.9026 Ignored bad PDB record found on line 1627 REMARK FullFitness: -1885.3206 Ignored bad PDB record found on line 1628 REMARK InterFull: -29.5572 Ignored bad PDB record found on line 1629 REMARK IntraFull: -21.6003 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 1681 REMARK Energy: -35.9026 Ignored bad PDB record found on line 1682 REMARK SimpleFitness: -35.9026 Ignored bad PDB record found on line 1683 REMARK FullFitness: -1885.3206 Ignored bad PDB record found on line 1684 REMARK InterFull: -29.5572 Ignored bad PDB record found on line 1685 REMARK IntraFull: -21.6003 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 1737 REMARK Energy: -35.9024 Ignored bad PDB record found on line 1738 REMARK SimpleFitness: -35.9024 Ignored bad PDB record found on line 1739 REMARK FullFitness: -1885.3103 Ignored bad PDB record found on line 1740 REMARK InterFull: -29.5614 Ignored bad PDB record found on line 1741 REMARK IntraFull: -21.5928 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 1793 REMARK Energy: -35.9024 Ignored bad PDB record found on line 1794 REMARK SimpleFitness: -35.9024 Ignored bad PDB record found on line 1795 REMARK FullFitness: -1885.3103 Ignored bad PDB record found on line 1796 REMARK InterFull: -29.5614 Ignored bad PDB record found on line 1797 REMARK IntraFull: -21.5928 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 1849 REMARK Energy: -35.9024 Ignored bad PDB record found on line 1850 REMARK SimpleFitness: -35.9024 Ignored bad PDB record found on line 1851 REMARK FullFitness: -1885.3103 Ignored bad PDB record found on line 1852 REMARK InterFull: -29.5614 Ignored bad PDB record found on line 1853 REMARK IntraFull: -21.5928 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 1905 REMARK Energy: -35.9024 Ignored bad PDB record found on line 1906 REMARK SimpleFitness: -35.9024 Ignored bad PDB record found on line 1907 REMARK FullFitness: -1885.3103 Ignored bad PDB record found on line 1908 REMARK InterFull: -29.5614 Ignored bad PDB record found on line 1909 REMARK IntraFull: -21.5928 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 1961 REMARK Energy: -35.9023 Ignored bad PDB record found on line 1962 REMARK SimpleFitness: -35.9023 Ignored bad PDB record found on line 1963 REMARK FullFitness: -1885.3088 Ignored bad PDB record found on line 1964 REMARK InterFull: -29.5435 Ignored bad PDB record found on line 1965 REMARK IntraFull: -21.6074 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 2017 REMARK Energy: -37.471 Ignored bad PDB record found on line 2018 REMARK SimpleFitness: -37.471 Ignored bad PDB record found on line 2019 REMARK FullFitness: -1884.768 Ignored bad PDB record found on line 2020 REMARK InterFull: -28.474 Ignored bad PDB record found on line 2021 REMARK IntraFull: -23.0398 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 2073 REMARK Energy: -37.471 Ignored bad PDB record found on line 2074 REMARK SimpleFitness: -37.471 Ignored bad PDB record found on line 2075 REMARK FullFitness: -1884.768 Ignored bad PDB record found on line 2076 REMARK InterFull: -28.474 Ignored bad PDB record found on line 2077 REMARK IntraFull: -23.0398 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 2129 REMARK Energy: -37.3906 Ignored bad PDB record found on line 2130 REMARK SimpleFitness: -37.3906 Ignored bad PDB record found on line 2131 REMARK FullFitness: -1884.6489 Ignored bad PDB record found on line 2132 REMARK InterFull: -28.4355 Ignored bad PDB record found on line 2133 REMARK IntraFull: -22.9795 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 2185 REMARK Energy: -34.4906 Ignored bad PDB record found on line 2186 REMARK SimpleFitness: -34.4906 Ignored bad PDB record found on line 2187 REMARK FullFitness: -1881.7797 Ignored bad PDB record found on line 2188 REMARK InterFull: -25.158 Ignored bad PDB record found on line 2189 REMARK IntraFull: -22.5786 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 2241 REMARK Energy: -34.4906 Ignored bad PDB record found on line 2242 REMARK SimpleFitness: -34.4906 Ignored bad PDB record found on line 2243 REMARK FullFitness: -1881.7797 Ignored bad PDB record found on line 2244 REMARK InterFull: -25.158 Ignored bad PDB record found on line 2245 REMARK IntraFull: -22.5786 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 2297 REMARK Energy: -34.4974 Ignored bad PDB record found on line 2298 REMARK SimpleFitness: -34.4974 Ignored bad PDB record found on line 2299 REMARK FullFitness: -1881.7012 Ignored bad PDB record found on line 2300 REMARK InterFull: -25.144 Ignored bad PDB record found on line 2301 REMARK IntraFull: -22.5382 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 2353 REMARK Energy: -34.4972 Ignored bad PDB record found on line 2354 REMARK SimpleFitness: -34.4972 Ignored bad PDB record found on line 2355 REMARK FullFitness: -1881.6809 Ignored bad PDB record found on line 2356 REMARK InterFull: -25.1353 Ignored bad PDB record found on line 2357 REMARK IntraFull: -22.5375 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 2409 REMARK Energy: -33.3639 Ignored bad PDB record found on line 2410 REMARK SimpleFitness: -33.3639 Ignored bad PDB record found on line 2411 REMARK FullFitness: -1881.4651 Ignored bad PDB record found on line 2412 REMARK InterFull: -23.915 Ignored bad PDB record found on line 2413 REMARK IntraFull: -23.6041 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 2465 REMARK Energy: -36.7831 Ignored bad PDB record found on line 2466 REMARK SimpleFitness: -36.7831 Ignored bad PDB record found on line 2467 REMARK FullFitness: -1884.416 Ignored bad PDB record found on line 2468 REMARK InterFull: -37.5974 Ignored bad PDB record found on line 2469 REMARK IntraFull: -20.8925 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 2521 REMARK Energy: -36.7831 Ignored bad PDB record found on line 2522 REMARK SimpleFitness: -36.7831 Ignored bad PDB record found on line 2523 REMARK FullFitness: -1884.416 Ignored bad PDB record found on line 2524 REMARK InterFull: -37.5974 Ignored bad PDB record found on line 2525 REMARK IntraFull: -20.8925 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 2577 REMARK Energy: -36.7847 Ignored bad PDB record found on line 2578 REMARK SimpleFitness: -36.7847 Ignored bad PDB record found on line 2579 REMARK FullFitness: -1884.4084 Ignored bad PDB record found on line 2580 REMARK InterFull: -37.6323 Ignored bad PDB record found on line 2581 REMARK IntraFull: -20.8582 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 2633 REMARK Energy: -36.7847 Ignored bad PDB record found on line 2634 REMARK SimpleFitness: -36.7847 Ignored bad PDB record found on line 2635 REMARK FullFitness: -1884.4084 Ignored bad PDB record found on line 2636 REMARK InterFull: -37.6323 Ignored bad PDB record found on line 2637 REMARK IntraFull: -20.8582 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 2689 REMARK Energy: -36.7847 Ignored bad PDB record found on line 2690 REMARK SimpleFitness: -36.7847 Ignored bad PDB record found on line 2691 REMARK FullFitness: -1884.4084 Ignored bad PDB record found on line 2692 REMARK InterFull: -37.6323 Ignored bad PDB record found on line 2693 REMARK IntraFull: -20.8582 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 2745 REMARK Energy: -36.7845 Ignored bad PDB record found on line 2746 REMARK SimpleFitness: -36.7845 Ignored bad PDB record found on line 2747 REMARK FullFitness: -1884.4028 Ignored bad PDB record found on line 2748 REMARK InterFull: -37.6679 Ignored bad PDB record found on line 2749 REMARK IntraFull: -20.827 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 2801 REMARK Energy: -36.7845 Ignored bad PDB record found on line 2802 REMARK SimpleFitness: -36.7845 Ignored bad PDB record found on line 2803 REMARK FullFitness: -1884.4028 Ignored bad PDB record found on line 2804 REMARK InterFull: -37.6679 Ignored bad PDB record found on line 2805 REMARK IntraFull: -20.827 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 2857 REMARK Energy: -36.7845 Ignored bad PDB record found on line 2858 REMARK SimpleFitness: -36.7845 Ignored bad PDB record found on line 2859 REMARK FullFitness: -1884.4028 Ignored bad PDB record found on line 2860 REMARK InterFull: -37.6679 Ignored bad PDB record found on line 2861 REMARK IntraFull: -20.827 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 2913 REMARK Energy: -39.1562 Ignored bad PDB record found on line 2914 REMARK SimpleFitness: -39.1562 Ignored bad PDB record found on line 2915 REMARK FullFitness: -1884.381 Ignored bad PDB record found on line 2916 REMARK InterFull: -31.9595 Ignored bad PDB record found on line 2917 REMARK IntraFull: -20.8785 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 2969 REMARK Energy: -38.2907 Ignored bad PDB record found on line 2970 REMARK SimpleFitness: -38.2907 Ignored bad PDB record found on line 2971 REMARK FullFitness: -1883.7123 Ignored bad PDB record found on line 2972 REMARK InterFull: -33.9855 Ignored bad PDB record found on line 2973 REMARK IntraFull: -18.4717 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 3025 REMARK Energy: -33.6242 Ignored bad PDB record found on line 3026 REMARK SimpleFitness: -33.6242 Ignored bad PDB record found on line 3027 REMARK FullFitness: -1879.7891 Ignored bad PDB record found on line 3028 REMARK InterFull: -31.695 Ignored bad PDB record found on line 3029 REMARK IntraFull: -19.198 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 3081 REMARK Energy: -33.4916 Ignored bad PDB record found on line 3082 REMARK SimpleFitness: -33.4916 Ignored bad PDB record found on line 3083 REMARK FullFitness: -1879.7067 Ignored bad PDB record found on line 3084 REMARK InterFull: -31.6537 Ignored bad PDB record found on line 3085 REMARK IntraFull: -19.1639 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 3137 REMARK Energy: -32.5131 Ignored bad PDB record found on line 3138 REMARK SimpleFitness: -32.5131 Ignored bad PDB record found on line 3139 REMARK FullFitness: -1878.5292 Ignored bad PDB record found on line 3140 REMARK InterFull: -31.7428 Ignored bad PDB record found on line 3141 REMARK IntraFull: -17.8953 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 3193 REMARK Energy: -15.7728 Ignored bad PDB record found on line 3194 REMARK SimpleFitness: -15.7728 Ignored bad PDB record found on line 3195 REMARK FullFitness: -1860.7526 Ignored bad PDB record found on line 3196 REMARK InterFull: -23.2681 Ignored bad PDB record found on line 3197 REMARK IntraFull: -5.60948 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 3249 REMARK Energy: -15.773 Ignored bad PDB record found on line 3250 REMARK SimpleFitness: -15.773 Ignored bad PDB record found on line 3251 REMARK FullFitness: -1860.7518 Ignored bad PDB record found on line 3252 REMARK InterFull: -23.252 Ignored bad PDB record found on line 3253 REMARK IntraFull: -5.62498 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 3305 REMARK Energy: -15.7729 Ignored bad PDB record found on line 3306 REMARK SimpleFitness: -15.7729 Ignored bad PDB record found on line 3307 REMARK FullFitness: -1860.7498 Ignored bad PDB record found on line 3308 REMARK InterFull: -23.2496 Ignored bad PDB record found on line 3309 REMARK IntraFull: -5.63422 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 3361 REMARK Energy: -34.0771 Ignored bad PDB record found on line 3362 REMARK SimpleFitness: -34.0771 Ignored bad PDB record found on line 3363 REMARK FullFitness: -1884.3728 Ignored bad PDB record found on line 3364 REMARK InterFull: -26.8907 Ignored bad PDB record found on line 3365 REMARK IntraFull: -22.3782 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 3417 REMARK Energy: -34.0771 Ignored bad PDB record found on line 3418 REMARK SimpleFitness: -34.0771 Ignored bad PDB record found on line 3419 REMARK FullFitness: -1884.3728 Ignored bad PDB record found on line 3420 REMARK InterFull: -26.8907 Ignored bad PDB record found on line 3421 REMARK IntraFull: -22.3782 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 3473 REMARK Energy: -34.0771 Ignored bad PDB record found on line 3474 REMARK SimpleFitness: -34.0771 Ignored bad PDB record found on line 3475 REMARK FullFitness: -1884.3728 Ignored bad PDB record found on line 3476 REMARK InterFull: -26.8907 Ignored bad PDB record found on line 3477 REMARK IntraFull: -22.3782 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 3529 REMARK Energy: -34.0781 Ignored bad PDB record found on line 3530 REMARK SimpleFitness: -34.0781 Ignored bad PDB record found on line 3531 REMARK FullFitness: -1884.3667 Ignored bad PDB record found on line 3532 REMARK InterFull: -26.9211 Ignored bad PDB record found on line 3533 REMARK IntraFull: -22.3416 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 3585 REMARK Energy: -34.0781 Ignored bad PDB record found on line 3586 REMARK SimpleFitness: -34.0781 Ignored bad PDB record found on line 3587 REMARK FullFitness: -1884.3667 Ignored bad PDB record found on line 3588 REMARK InterFull: -26.9211 Ignored bad PDB record found on line 3589 REMARK IntraFull: -22.3416 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 3641 REMARK Energy: -34.0788 Ignored bad PDB record found on line 3642 REMARK SimpleFitness: -34.0788 Ignored bad PDB record found on line 3643 REMARK FullFitness: -1884.3599 Ignored bad PDB record found on line 3644 REMARK InterFull: -26.9167 Ignored bad PDB record found on line 3645 REMARK IntraFull: -22.341 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 3697 REMARK Energy: -34.0788 Ignored bad PDB record found on line 3698 REMARK SimpleFitness: -34.0788 Ignored bad PDB record found on line 3699 REMARK FullFitness: -1884.3599 Ignored bad PDB record found on line 3700 REMARK InterFull: -26.9167 Ignored bad PDB record found on line 3701 REMARK IntraFull: -22.341 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 3753 REMARK Energy: -34.0788 Ignored bad PDB record found on line 3754 REMARK SimpleFitness: -34.0788 Ignored bad PDB record found on line 3755 REMARK FullFitness: -1884.3599 Ignored bad PDB record found on line 3756 REMARK InterFull: -26.9167 Ignored bad PDB record found on line 3757 REMARK IntraFull: -22.341 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 3809 REMARK Energy: -38.6966 Ignored bad PDB record found on line 3810 REMARK SimpleFitness: -38.6966 Ignored bad PDB record found on line 3811 REMARK FullFitness: -1884.3284 Ignored bad PDB record found on line 3812 REMARK InterFull: -31.2445 Ignored bad PDB record found on line 3813 REMARK IntraFull: -23.85 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 3865 REMARK Energy: -38.6966 Ignored bad PDB record found on line 3866 REMARK SimpleFitness: -38.6966 Ignored bad PDB record found on line 3867 REMARK FullFitness: -1884.3284 Ignored bad PDB record found on line 3868 REMARK InterFull: -31.2445 Ignored bad PDB record found on line 3869 REMARK IntraFull: -23.85 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 3921 REMARK Energy: -38.71 Ignored bad PDB record found on line 3922 REMARK SimpleFitness: -38.71 Ignored bad PDB record found on line 3923 REMARK FullFitness: -1884.3188 Ignored bad PDB record found on line 3924 REMARK InterFull: -31.2045 Ignored bad PDB record found on line 3925 REMARK IntraFull: -23.8933 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 3977 REMARK Energy: -38.7105 Ignored bad PDB record found on line 3978 REMARK SimpleFitness: -38.7105 Ignored bad PDB record found on line 3979 REMARK FullFitness: -1884.3115 Ignored bad PDB record found on line 3980 REMARK InterFull: -31.1957 Ignored bad PDB record found on line 3981 REMARK IntraFull: -23.894 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 4033 REMARK Energy: -38.7105 Ignored bad PDB record found on line 4034 REMARK SimpleFitness: -38.7105 Ignored bad PDB record found on line 4035 REMARK FullFitness: -1884.3115 Ignored bad PDB record found on line 4036 REMARK InterFull: -31.1957 Ignored bad PDB record found on line 4037 REMARK IntraFull: -23.894 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 4089 REMARK Energy: -38.7105 Ignored bad PDB record found on line 4090 REMARK SimpleFitness: -38.7105 Ignored bad PDB record found on line 4091 REMARK FullFitness: -1884.3115 Ignored bad PDB record found on line 4092 REMARK InterFull: -31.1957 Ignored bad PDB record found on line 4093 REMARK IntraFull: -23.894 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 4145 REMARK Energy: -38.7105 Ignored bad PDB record found on line 4146 REMARK SimpleFitness: -38.7105 Ignored bad PDB record found on line 4147 REMARK FullFitness: -1884.3115 Ignored bad PDB record found on line 4148 REMARK InterFull: -31.1957 Ignored bad PDB record found on line 4149 REMARK IntraFull: -23.894 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 4201 REMARK Energy: -38.7105 Ignored bad PDB record found on line 4202 REMARK SimpleFitness: -38.7105 Ignored bad PDB record found on line 4203 REMARK FullFitness: -1884.3115 Ignored bad PDB record found on line 4204 REMARK InterFull: -31.1957 Ignored bad PDB record found on line 4205 REMARK IntraFull: -23.894 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 4257 REMARK Energy: -32.4073 Ignored bad PDB record found on line 4258 REMARK SimpleFitness: -32.4073 Ignored bad PDB record found on line 4259 REMARK FullFitness: -1884.0887 Ignored bad PDB record found on line 4260 REMARK InterFull: -25.4981 Ignored bad PDB record found on line 4261 REMARK IntraFull: -23.9606 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 4313 REMARK Energy: -32.4023 Ignored bad PDB record found on line 4314 REMARK SimpleFitness: -32.4023 Ignored bad PDB record found on line 4315 REMARK FullFitness: -1884.0819 Ignored bad PDB record found on line 4316 REMARK InterFull: -25.5137 Ignored bad PDB record found on line 4317 REMARK IntraFull: -23.9493 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 4369 REMARK Energy: -32.3675 Ignored bad PDB record found on line 4370 REMARK SimpleFitness: -32.3675 Ignored bad PDB record found on line 4371 REMARK FullFitness: -1884.0652 Ignored bad PDB record found on line 4372 REMARK InterFull: -25.4197 Ignored bad PDB record found on line 4373 REMARK IntraFull: -24.0724 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 4425 REMARK Energy: -31.4816 Ignored bad PDB record found on line 4426 REMARK SimpleFitness: -31.4816 Ignored bad PDB record found on line 4427 REMARK FullFitness: -1882.9314 Ignored bad PDB record found on line 4428 REMARK InterFull: -24.5728 Ignored bad PDB record found on line 4429 REMARK IntraFull: -24.2694 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 4481 REMARK Energy: -31.5616 Ignored bad PDB record found on line 4482 REMARK SimpleFitness: -31.5616 Ignored bad PDB record found on line 4483 REMARK FullFitness: -1882.9258 Ignored bad PDB record found on line 4484 REMARK InterFull: -24.8659 Ignored bad PDB record found on line 4485 REMARK IntraFull: -24.07 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 4537 REMARK Energy: -31.4129 Ignored bad PDB record found on line 4538 REMARK SimpleFitness: -31.4129 Ignored bad PDB record found on line 4539 REMARK FullFitness: -1882.7587 Ignored bad PDB record found on line 4540 REMARK InterFull: -25.1046 Ignored bad PDB record found on line 4541 REMARK IntraFull: -23.6261 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 4593 REMARK Energy: -29.3414 Ignored bad PDB record found on line 4594 REMARK SimpleFitness: -29.3414 Ignored bad PDB record found on line 4595 REMARK FullFitness: -1880.7476 Ignored bad PDB record found on line 4596 REMARK InterFull: -23.1685 Ignored bad PDB record found on line 4597 REMARK IntraFull: -22.9569 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 4649 REMARK Energy: -28.9268 Ignored bad PDB record found on line 4650 REMARK SimpleFitness: -28.9268 Ignored bad PDB record found on line 4651 REMARK FullFitness: -1880.2692 Ignored bad PDB record found on line 4652 REMARK InterFull: -22.7469 Ignored bad PDB record found on line 4653 REMARK IntraFull: -22.8861 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 4705 REMARK Energy: -38.1896 Ignored bad PDB record found on line 4706 REMARK SimpleFitness: -38.1896 Ignored bad PDB record found on line 4707 REMARK FullFitness: -1883.9634 Ignored bad PDB record found on line 4708 REMARK InterFull: -34.5696 Ignored bad PDB record found on line 4709 REMARK IntraFull: -23.1948 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 4761 REMARK Energy: -38.2501 Ignored bad PDB record found on line 4762 REMARK SimpleFitness: -38.2501 Ignored bad PDB record found on line 4763 REMARK FullFitness: -1883.394 Ignored bad PDB record found on line 4764 REMARK InterFull: -35.4585 Ignored bad PDB record found on line 4765 REMARK IntraFull: -22.5047 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 4817 REMARK Energy: -38.7838 Ignored bad PDB record found on line 4818 REMARK SimpleFitness: -38.7838 Ignored bad PDB record found on line 4819 REMARK FullFitness: -1882.8265 Ignored bad PDB record found on line 4820 REMARK InterFull: -37.1027 Ignored bad PDB record found on line 4821 REMARK IntraFull: -21.161 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 4873 REMARK Energy: -38.7839 Ignored bad PDB record found on line 4874 REMARK SimpleFitness: -38.7839 Ignored bad PDB record found on line 4875 REMARK FullFitness: -1882.8224 Ignored bad PDB record found on line 4876 REMARK InterFull: -37.1028 Ignored bad PDB record found on line 4877 REMARK IntraFull: -21.1576 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 4929 REMARK Energy: -38.7809 Ignored bad PDB record found on line 4930 REMARK SimpleFitness: -38.7809 Ignored bad PDB record found on line 4931 REMARK FullFitness: -1882.7941 Ignored bad PDB record found on line 4932 REMARK InterFull: -37.0758 Ignored bad PDB record found on line 4933 REMARK IntraFull: -21.1763 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 4985 REMARK Energy: -35.6473 Ignored bad PDB record found on line 4986 REMARK SimpleFitness: -35.6473 Ignored bad PDB record found on line 4987 REMARK FullFitness: -1879.2168 Ignored bad PDB record found on line 4988 REMARK InterFull: -36.0662 Ignored bad PDB record found on line 4989 REMARK IntraFull: -18.3757 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 5041 REMARK Energy: -34.1965 Ignored bad PDB record found on line 5042 REMARK SimpleFitness: -34.1965 Ignored bad PDB record found on line 5043 REMARK FullFitness: -1879.1459 Ignored bad PDB record found on line 5044 REMARK InterFull: -33.9689 Ignored bad PDB record found on line 5045 REMARK IntraFull: -19.2709 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 5097 REMARK Energy: -35.1626 Ignored bad PDB record found on line 5098 REMARK SimpleFitness: -35.1626 Ignored bad PDB record found on line 5099 REMARK FullFitness: -1878.1886 Ignored bad PDB record found on line 5100 REMARK InterFull: -37.026 Ignored bad PDB record found on line 5101 REMARK IntraFull: -16.7045 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 5153 REMARK Energy: -32.697 Ignored bad PDB record found on line 5154 REMARK SimpleFitness: -32.697 Ignored bad PDB record found on line 5155 REMARK FullFitness: -1883.9535 Ignored bad PDB record found on line 5156 REMARK InterFull: -24.4008 Ignored bad PDB record found on line 5157 REMARK IntraFull: -24.6268 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 5209 REMARK Energy: -32.7884 Ignored bad PDB record found on line 5210 REMARK SimpleFitness: -32.7884 Ignored bad PDB record found on line 5211 REMARK FullFitness: -1883.9207 Ignored bad PDB record found on line 5212 REMARK InterFull: -25.3225 Ignored bad PDB record found on line 5213 REMARK IntraFull: -25.3732 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 5265 REMARK Energy: -32.7884 Ignored bad PDB record found on line 5266 REMARK SimpleFitness: -32.7884 Ignored bad PDB record found on line 5267 REMARK FullFitness: -1883.9207 Ignored bad PDB record found on line 5268 REMARK InterFull: -25.3225 Ignored bad PDB record found on line 5269 REMARK IntraFull: -25.3732 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 5321 REMARK Energy: -32.6833 Ignored bad PDB record found on line 5322 REMARK SimpleFitness: -32.6833 Ignored bad PDB record found on line 5323 REMARK FullFitness: -1883.9053 Ignored bad PDB record found on line 5324 REMARK InterFull: -24.442 Ignored bad PDB record found on line 5325 REMARK IntraFull: -24.4013 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 5377 REMARK Energy: -32.6833 Ignored bad PDB record found on line 5378 REMARK SimpleFitness: -32.6833 Ignored bad PDB record found on line 5379 REMARK FullFitness: -1883.9053 Ignored bad PDB record found on line 5380 REMARK InterFull: -24.442 Ignored bad PDB record found on line 5381 REMARK IntraFull: -24.4013 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 5433 REMARK Energy: -32.3892 Ignored bad PDB record found on line 5434 REMARK SimpleFitness: -32.3892 Ignored bad PDB record found on line 5435 REMARK FullFitness: -1883.6228 Ignored bad PDB record found on line 5436 REMARK InterFull: -24.3845 Ignored bad PDB record found on line 5437 REMARK IntraFull: -24.0052 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 5489 REMARK Energy: -32.24 Ignored bad PDB record found on line 5490 REMARK SimpleFitness: -32.24 Ignored bad PDB record found on line 5491 REMARK FullFitness: -1883.5354 Ignored bad PDB record found on line 5492 REMARK InterFull: -25.0396 Ignored bad PDB record found on line 5493 REMARK IntraFull: -24.97 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 5545 REMARK Energy: -31.9993 Ignored bad PDB record found on line 5546 REMARK SimpleFitness: -31.9993 Ignored bad PDB record found on line 5547 REMARK FullFitness: -1883.3958 Ignored bad PDB record found on line 5548 REMARK InterFull: -24.8787 Ignored bad PDB record found on line 5549 REMARK IntraFull: -25.0113 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 5601 REMARK Energy: -34.0013 Ignored bad PDB record found on line 5602 REMARK SimpleFitness: -34.0013 Ignored bad PDB record found on line 5603 REMARK FullFitness: -1883.9265 Ignored bad PDB record found on line 5604 REMARK InterFull: -23.4052 Ignored bad PDB record found on line 5605 REMARK IntraFull: -25.4654 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 5657 REMARK Energy: -34.0013 Ignored bad PDB record found on line 5658 REMARK SimpleFitness: -34.0013 Ignored bad PDB record found on line 5659 REMARK FullFitness: -1883.9265 Ignored bad PDB record found on line 5660 REMARK InterFull: -23.4052 Ignored bad PDB record found on line 5661 REMARK IntraFull: -25.4654 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 5713 REMARK Energy: -34.0013 Ignored bad PDB record found on line 5714 REMARK SimpleFitness: -34.0013 Ignored bad PDB record found on line 5715 REMARK FullFitness: -1883.9265 Ignored bad PDB record found on line 5716 REMARK InterFull: -23.4052 Ignored bad PDB record found on line 5717 REMARK IntraFull: -25.4654 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 5769 REMARK Energy: -33.8547 Ignored bad PDB record found on line 5770 REMARK SimpleFitness: -33.8547 Ignored bad PDB record found on line 5771 REMARK FullFitness: -1883.6704 Ignored bad PDB record found on line 5772 REMARK InterFull: -26.734 Ignored bad PDB record found on line 5773 REMARK IntraFull: -21.8783 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 5825 REMARK Energy: -33.8547 Ignored bad PDB record found on line 5826 REMARK SimpleFitness: -33.8547 Ignored bad PDB record found on line 5827 REMARK FullFitness: -1883.6704 Ignored bad PDB record found on line 5828 REMARK InterFull: -26.734 Ignored bad PDB record found on line 5829 REMARK IntraFull: -21.8783 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 5881 REMARK Energy: -33.8559 Ignored bad PDB record found on line 5882 REMARK SimpleFitness: -33.8559 Ignored bad PDB record found on line 5883 REMARK FullFitness: -1883.6648 Ignored bad PDB record found on line 5884 REMARK InterFull: -26.755 Ignored bad PDB record found on line 5885 REMARK IntraFull: -21.8627 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 5937 REMARK Energy: -33.8559 Ignored bad PDB record found on line 5938 REMARK SimpleFitness: -33.8559 Ignored bad PDB record found on line 5939 REMARK FullFitness: -1883.6648 Ignored bad PDB record found on line 5940 REMARK InterFull: -26.755 Ignored bad PDB record found on line 5941 REMARK IntraFull: -21.8627 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 5993 REMARK Energy: -33.8559 Ignored bad PDB record found on line 5994 REMARK SimpleFitness: -33.8559 Ignored bad PDB record found on line 5995 REMARK FullFitness: -1883.6648 Ignored bad PDB record found on line 5996 REMARK InterFull: -26.755 Ignored bad PDB record found on line 5997 REMARK IntraFull: -21.8627 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 6049 REMARK Energy: -33.2119 Ignored bad PDB record found on line 6050 REMARK SimpleFitness: -33.2119 Ignored bad PDB record found on line 6051 REMARK FullFitness: -1883.8195 Ignored bad PDB record found on line 6052 REMARK InterFull: -25.0031 Ignored bad PDB record found on line 6053 REMARK IntraFull: -26.8542 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 6105 REMARK Energy: -33.2119 Ignored bad PDB record found on line 6106 REMARK SimpleFitness: -33.2119 Ignored bad PDB record found on line 6107 REMARK FullFitness: -1883.8195 Ignored bad PDB record found on line 6108 REMARK InterFull: -25.0031 Ignored bad PDB record found on line 6109 REMARK IntraFull: -26.8542 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 6161 REMARK Energy: -33.2119 Ignored bad PDB record found on line 6162 REMARK SimpleFitness: -33.2119 Ignored bad PDB record found on line 6163 REMARK FullFitness: -1883.8195 Ignored bad PDB record found on line 6164 REMARK InterFull: -25.0031 Ignored bad PDB record found on line 6165 REMARK IntraFull: -26.8542 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 6217 REMARK Energy: -33.2119 Ignored bad PDB record found on line 6218 REMARK SimpleFitness: -33.2119 Ignored bad PDB record found on line 6219 REMARK FullFitness: -1883.8195 Ignored bad PDB record found on line 6220 REMARK InterFull: -25.0031 Ignored bad PDB record found on line 6221 REMARK IntraFull: -26.8542 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 6273 REMARK Energy: -31.6235 Ignored bad PDB record found on line 6274 REMARK SimpleFitness: -31.6235 Ignored bad PDB record found on line 6275 REMARK FullFitness: -1882.0529 Ignored bad PDB record found on line 6276 REMARK InterFull: -23.9375 Ignored bad PDB record found on line 6277 REMARK IntraFull: -25.8164 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 6329 REMARK Energy: -31.3571 Ignored bad PDB record found on line 6330 REMARK SimpleFitness: -31.3571 Ignored bad PDB record found on line 6331 REMARK FullFitness: -1881.7253 Ignored bad PDB record found on line 6332 REMARK InterFull: -23.8041 Ignored bad PDB record found on line 6333 REMARK IntraFull: -25.562 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 6385 REMARK Energy: -31.3571 Ignored bad PDB record found on line 6386 REMARK SimpleFitness: -31.3571 Ignored bad PDB record found on line 6387 REMARK FullFitness: -1881.7253 Ignored bad PDB record found on line 6388 REMARK InterFull: -23.8041 Ignored bad PDB record found on line 6389 REMARK IntraFull: -25.562 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 6441 REMARK Energy: -31.3571 Ignored bad PDB record found on line 6442 REMARK SimpleFitness: -31.3571 Ignored bad PDB record found on line 6443 REMARK FullFitness: -1881.7253 Ignored bad PDB record found on line 6444 REMARK InterFull: -23.8041 Ignored bad PDB record found on line 6445 REMARK IntraFull: -25.562 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 6497 REMARK Energy: -33.9947 Ignored bad PDB record found on line 6498 REMARK SimpleFitness: -33.9947 Ignored bad PDB record found on line 6499 REMARK FullFitness: -1883.4872 Ignored bad PDB record found on line 6500 REMARK InterFull: -27.2134 Ignored bad PDB record found on line 6501 REMARK IntraFull: -22.9139 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 6553 REMARK Energy: -33.9906 Ignored bad PDB record found on line 6554 REMARK SimpleFitness: -33.9906 Ignored bad PDB record found on line 6555 REMARK FullFitness: -1883.4594 Ignored bad PDB record found on line 6556 REMARK InterFull: -27.1906 Ignored bad PDB record found on line 6557 REMARK IntraFull: -22.9468 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 6609 REMARK Energy: -33.9865 Ignored bad PDB record found on line 6610 REMARK SimpleFitness: -33.9865 Ignored bad PDB record found on line 6611 REMARK FullFitness: -1883.452 Ignored bad PDB record found on line 6612 REMARK InterFull: -27.1608 Ignored bad PDB record found on line 6613 REMARK IntraFull: -22.9812 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 6665 REMARK Energy: -32.1562 Ignored bad PDB record found on line 6666 REMARK SimpleFitness: -32.1562 Ignored bad PDB record found on line 6667 REMARK FullFitness: -1882.1472 Ignored bad PDB record found on line 6668 REMARK InterFull: -26.14 Ignored bad PDB record found on line 6669 REMARK IntraFull: -21.7271 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 6721 REMARK Energy: -32.1385 Ignored bad PDB record found on line 6722 REMARK SimpleFitness: -32.1385 Ignored bad PDB record found on line 6723 REMARK FullFitness: -1882.1221 Ignored bad PDB record found on line 6724 REMARK InterFull: -26.4416 Ignored bad PDB record found on line 6725 REMARK IntraFull: -21.4114 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 6777 REMARK Energy: -32.1385 Ignored bad PDB record found on line 6778 REMARK SimpleFitness: -32.1385 Ignored bad PDB record found on line 6779 REMARK FullFitness: -1882.1221 Ignored bad PDB record found on line 6780 REMARK InterFull: -26.4416 Ignored bad PDB record found on line 6781 REMARK IntraFull: -21.4114 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 6833 REMARK Energy: -31.6455 Ignored bad PDB record found on line 6834 REMARK SimpleFitness: -31.6455 Ignored bad PDB record found on line 6835 REMARK FullFitness: -1881.6796 Ignored bad PDB record found on line 6836 REMARK InterFull: -25.7285 Ignored bad PDB record found on line 6837 REMARK IntraFull: -21.4829 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 6889 REMARK Energy: -31.6455 Ignored bad PDB record found on line 6890 REMARK SimpleFitness: -31.6455 Ignored bad PDB record found on line 6891 REMARK FullFitness: -1881.6796 Ignored bad PDB record found on line 6892 REMARK InterFull: -25.7285 Ignored bad PDB record found on line 6893 REMARK IntraFull: -21.4829 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 6945 REMARK Energy: -33.9058 Ignored bad PDB record found on line 6946 REMARK SimpleFitness: -33.9058 Ignored bad PDB record found on line 6947 REMARK FullFitness: -1883.4578 Ignored bad PDB record found on line 6948 REMARK InterFull: -24.8854 Ignored bad PDB record found on line 6949 REMARK IntraFull: -26.7624 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 7001 REMARK Energy: -32.5725 Ignored bad PDB record found on line 7002 REMARK SimpleFitness: -32.5725 Ignored bad PDB record found on line 7003 REMARK FullFitness: -1882.0406 Ignored bad PDB record found on line 7004 REMARK InterFull: -24.1431 Ignored bad PDB record found on line 7005 REMARK IntraFull: -25.8754 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 7057 REMARK Energy: -32.6109 Ignored bad PDB record found on line 7058 REMARK SimpleFitness: -32.6109 Ignored bad PDB record found on line 7059 REMARK FullFitness: -1881.9852 Ignored bad PDB record found on line 7060 REMARK InterFull: -24.1639 Ignored bad PDB record found on line 7061 REMARK IntraFull: -25.8101 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 7113 REMARK Energy: -31.6118 Ignored bad PDB record found on line 7114 REMARK SimpleFitness: -31.6118 Ignored bad PDB record found on line 7115 REMARK FullFitness: -1880.5256 Ignored bad PDB record found on line 7116 REMARK InterFull: -24.5384 Ignored bad PDB record found on line 7117 REMARK IntraFull: -24.5031 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 7169 REMARK Energy: -31.0597 Ignored bad PDB record found on line 7170 REMARK SimpleFitness: -31.0597 Ignored bad PDB record found on line 7171 REMARK FullFitness: -1879.9412 Ignored bad PDB record found on line 7172 REMARK InterFull: -23.7386 Ignored bad PDB record found on line 7173 REMARK IntraFull: -24.6987 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 7225 REMARK Energy: -31.0597 Ignored bad PDB record found on line 7226 REMARK SimpleFitness: -31.0597 Ignored bad PDB record found on line 7227 REMARK FullFitness: -1879.9412 Ignored bad PDB record found on line 7228 REMARK InterFull: -23.7386 Ignored bad PDB record found on line 7229 REMARK IntraFull: -24.6987 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 7281 REMARK Energy: -30.3002 Ignored bad PDB record found on line 7282 REMARK SimpleFitness: -30.3002 Ignored bad PDB record found on line 7283 REMARK FullFitness: -1879.1617 Ignored bad PDB record found on line 7284 REMARK InterFull: -22.9409 Ignored bad PDB record found on line 7285 REMARK IntraFull: -24.7458 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 7337 REMARK Energy: -30.3002 Ignored bad PDB record found on line 7338 REMARK SimpleFitness: -30.3002 Ignored bad PDB record found on line 7339 REMARK FullFitness: -1879.1617 Ignored bad PDB record found on line 7340 REMARK InterFull: -22.9409 Ignored bad PDB record found on line 7341 REMARK IntraFull: -24.7458 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 7393 REMARK Energy: -39.2163 Ignored bad PDB record found on line 7394 REMARK SimpleFitness: -39.2163 Ignored bad PDB record found on line 7395 REMARK FullFitness: -1883.3319 Ignored bad PDB record found on line 7396 REMARK InterFull: -41.373 Ignored bad PDB record found on line 7397 REMARK IntraFull: -17.442 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 7449 REMARK Energy: -36.9806 Ignored bad PDB record found on line 7450 REMARK SimpleFitness: -36.9806 Ignored bad PDB record found on line 7451 REMARK FullFitness: -1882.6824 Ignored bad PDB record found on line 7452 REMARK InterFull: -39.4974 Ignored bad PDB record found on line 7453 REMARK IntraFull: -17.3859 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 7505 REMARK Energy: -44.3259 Ignored bad PDB record found on line 7506 REMARK SimpleFitness: -44.3259 Ignored bad PDB record found on line 7507 REMARK FullFitness: -1883.2649 Ignored bad PDB record found on line 7508 REMARK InterFull: -39.5245 Ignored bad PDB record found on line 7509 REMARK IntraFull: -20.8813 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 7561 REMARK Energy: -42.6127 Ignored bad PDB record found on line 7562 REMARK SimpleFitness: -42.6127 Ignored bad PDB record found on line 7563 REMARK FullFitness: -1880.498 Ignored bad PDB record found on line 7564 REMARK InterFull: -38.5181 Ignored bad PDB record found on line 7565 REMARK IntraFull: -20.57 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 7617 REMARK Energy: -37.4504 Ignored bad PDB record found on line 7618 REMARK SimpleFitness: -37.4504 Ignored bad PDB record found on line 7619 REMARK FullFitness: -1883.2255 Ignored bad PDB record found on line 7620 REMARK InterFull: -27.0059 Ignored bad PDB record found on line 7621 REMARK IntraFull: -26.8206 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 7673 REMARK Energy: -38.0997 Ignored bad PDB record found on line 7674 REMARK SimpleFitness: -38.0997 Ignored bad PDB record found on line 7675 REMARK FullFitness: -1882.9167 Ignored bad PDB record found on line 7676 REMARK InterFull: -28.3006 Ignored bad PDB record found on line 7677 REMARK IntraFull: -25.5831 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 7729 REMARK Energy: -38.0938 Ignored bad PDB record found on line 7730 REMARK SimpleFitness: -38.0938 Ignored bad PDB record found on line 7731 REMARK FullFitness: -1882.9045 Ignored bad PDB record found on line 7732 REMARK InterFull: -28.3385 Ignored bad PDB record found on line 7733 REMARK IntraFull: -25.5341 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 7785 REMARK Energy: -32.4087 Ignored bad PDB record found on line 7786 REMARK SimpleFitness: -32.4087 Ignored bad PDB record found on line 7787 REMARK FullFitness: -1878.6672 Ignored bad PDB record found on line 7788 REMARK InterFull: -27.5318 Ignored bad PDB record found on line 7789 REMARK IntraFull: -21.2114 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 7841 REMARK Energy: -17.6792 Ignored bad PDB record found on line 7842 REMARK SimpleFitness: -17.6792 Ignored bad PDB record found on line 7843 REMARK FullFitness: -1863.8474 Ignored bad PDB record found on line 7844 REMARK InterFull: -24.9996 Ignored bad PDB record found on line 7845 REMARK IntraFull: -8.88582 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 7897 REMARK Energy: -41.0171 Ignored bad PDB record found on line 7898 REMARK SimpleFitness: -41.0171 Ignored bad PDB record found on line 7899 REMARK FullFitness: -1883.102 Ignored bad PDB record found on line 7900 REMARK InterFull: -34.8909 Ignored bad PDB record found on line 7901 REMARK IntraFull: -24.4243 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 7953 REMARK Energy: -40.9701 Ignored bad PDB record found on line 7954 REMARK SimpleFitness: -40.9701 Ignored bad PDB record found on line 7955 REMARK FullFitness: -1882.9971 Ignored bad PDB record found on line 7956 REMARK InterFull: -34.9541 Ignored bad PDB record found on line 7957 REMARK IntraFull: -24.33 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 8009 REMARK Energy: -40.9296 Ignored bad PDB record found on line 8010 REMARK SimpleFitness: -40.9296 Ignored bad PDB record found on line 8011 REMARK FullFitness: -1882.3888 Ignored bad PDB record found on line 8012 REMARK InterFull: -34.6634 Ignored bad PDB record found on line 8013 REMARK IntraFull: -24.4795 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 8065 REMARK Energy: -39.7998 Ignored bad PDB record found on line 8066 REMARK SimpleFitness: -39.7998 Ignored bad PDB record found on line 8067 REMARK FullFitness: -1878.6735 Ignored bad PDB record found on line 8068 REMARK InterFull: -31.1866 Ignored bad PDB record found on line 8069 REMARK IntraFull: -22.5698 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 8121 REMARK Energy: -39.9842 Ignored bad PDB record found on line 8122 REMARK SimpleFitness: -39.9842 Ignored bad PDB record found on line 8123 REMARK FullFitness: -1883.0886 Ignored bad PDB record found on line 8124 REMARK InterFull: -33.6754 Ignored bad PDB record found on line 8125 REMARK IntraFull: -25.0883 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 8177 REMARK Energy: -39.9842 Ignored bad PDB record found on line 8178 REMARK SimpleFitness: -39.9842 Ignored bad PDB record found on line 8179 REMARK FullFitness: -1883.0886 Ignored bad PDB record found on line 8180 REMARK InterFull: -33.6754 Ignored bad PDB record found on line 8181 REMARK IntraFull: -25.0883 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 8233 REMARK Energy: -39.9842 Ignored bad PDB record found on line 8234 REMARK SimpleFitness: -39.9842 Ignored bad PDB record found on line 8235 REMARK FullFitness: -1883.0886 Ignored bad PDB record found on line 8236 REMARK InterFull: -33.6754 Ignored bad PDB record found on line 8237 REMARK IntraFull: -25.0883 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 8289 REMARK Energy: -39.9877 Ignored bad PDB record found on line 8290 REMARK SimpleFitness: -39.9877 Ignored bad PDB record found on line 8291 REMARK FullFitness: -1883.0845 Ignored bad PDB record found on line 8292 REMARK InterFull: -33.7555 Ignored bad PDB record found on line 8293 REMARK IntraFull: -25.094 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 8345 REMARK Energy: -39.9877 Ignored bad PDB record found on line 8346 REMARK SimpleFitness: -39.9877 Ignored bad PDB record found on line 8347 REMARK FullFitness: -1883.0845 Ignored bad PDB record found on line 8348 REMARK InterFull: -33.7555 Ignored bad PDB record found on line 8349 REMARK IntraFull: -25.094 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 8401 REMARK Energy: -39.9718 Ignored bad PDB record found on line 8402 REMARK SimpleFitness: -39.9718 Ignored bad PDB record found on line 8403 REMARK FullFitness: -1883.0358 Ignored bad PDB record found on line 8404 REMARK InterFull: -33.9638 Ignored bad PDB record found on line 8405 REMARK IntraFull: -25.1219 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 8457 REMARK Energy: -39.9718 Ignored bad PDB record found on line 8458 REMARK SimpleFitness: -39.9718 Ignored bad PDB record found on line 8459 REMARK FullFitness: -1883.0358 Ignored bad PDB record found on line 8460 REMARK InterFull: -33.9638 Ignored bad PDB record found on line 8461 REMARK IntraFull: -25.1219 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 8513 REMARK Energy: -39.9718 Ignored bad PDB record found on line 8514 REMARK SimpleFitness: -39.9718 Ignored bad PDB record found on line 8515 REMARK FullFitness: -1883.0358 Ignored bad PDB record found on line 8516 REMARK InterFull: -33.9638 Ignored bad PDB record found on line 8517 REMARK IntraFull: -25.1219 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 8569 REMARK Energy: -38.3239 Ignored bad PDB record found on line 8570 REMARK SimpleFitness: -38.3239 Ignored bad PDB record found on line 8571 REMARK FullFitness: -1882.909 Ignored bad PDB record found on line 8572 REMARK InterFull: -35.0069 Ignored bad PDB record found on line 8573 REMARK IntraFull: -24.5382 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 8625 REMARK Energy: -38.3239 Ignored bad PDB record found on line 8626 REMARK SimpleFitness: -38.3239 Ignored bad PDB record found on line 8627 REMARK FullFitness: -1882.909 Ignored bad PDB record found on line 8628 REMARK InterFull: -35.0069 Ignored bad PDB record found on line 8629 REMARK IntraFull: -24.5382 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 8681 REMARK Energy: -38.3227 Ignored bad PDB record found on line 8682 REMARK SimpleFitness: -38.3227 Ignored bad PDB record found on line 8683 REMARK FullFitness: -1882.8707 Ignored bad PDB record found on line 8684 REMARK InterFull: -34.9946 Ignored bad PDB record found on line 8685 REMARK IntraFull: -24.5342 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 8737 REMARK Energy: -38.3227 Ignored bad PDB record found on line 8738 REMARK SimpleFitness: -38.3227 Ignored bad PDB record found on line 8739 REMARK FullFitness: -1882.8707 Ignored bad PDB record found on line 8740 REMARK InterFull: -34.9946 Ignored bad PDB record found on line 8741 REMARK IntraFull: -24.5342 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 8793 REMARK Energy: -38.3227 Ignored bad PDB record found on line 8794 REMARK SimpleFitness: -38.3227 Ignored bad PDB record found on line 8795 REMARK FullFitness: -1882.8707 Ignored bad PDB record found on line 8796 REMARK InterFull: -34.9946 Ignored bad PDB record found on line 8797 REMARK IntraFull: -24.5342 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 8849 REMARK Energy: -38.3227 Ignored bad PDB record found on line 8850 REMARK SimpleFitness: -38.3227 Ignored bad PDB record found on line 8851 REMARK FullFitness: -1882.8707 Ignored bad PDB record found on line 8852 REMARK InterFull: -34.9946 Ignored bad PDB record found on line 8853 REMARK IntraFull: -24.5342 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 8905 REMARK Energy: -38.3222 Ignored bad PDB record found on line 8906 REMARK SimpleFitness: -38.3222 Ignored bad PDB record found on line 8907 REMARK FullFitness: -1882.8688 Ignored bad PDB record found on line 8908 REMARK InterFull: -34.9896 Ignored bad PDB record found on line 8909 REMARK IntraFull: -24.5382 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 8961 REMARK Energy: -38.3222 Ignored bad PDB record found on line 8962 REMARK SimpleFitness: -38.3222 Ignored bad PDB record found on line 8963 REMARK FullFitness: -1882.8688 Ignored bad PDB record found on line 8964 REMARK InterFull: -34.9896 Ignored bad PDB record found on line 8965 REMARK IntraFull: -24.5382 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 9017 REMARK Energy: -31.1571 Ignored bad PDB record found on line 9018 REMARK SimpleFitness: -31.1571 Ignored bad PDB record found on line 9019 REMARK FullFitness: -1882.8102 Ignored bad PDB record found on line 9020 REMARK InterFull: -25.1157 Ignored bad PDB record found on line 9021 REMARK IntraFull: -24.0024 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 9073 REMARK Energy: -31.1571 Ignored bad PDB record found on line 9074 REMARK SimpleFitness: -31.1571 Ignored bad PDB record found on line 9075 REMARK FullFitness: -1882.8102 Ignored bad PDB record found on line 9076 REMARK InterFull: -25.1157 Ignored bad PDB record found on line 9077 REMARK IntraFull: -24.0024 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 9129 REMARK Energy: -31.1526 Ignored bad PDB record found on line 9130 REMARK SimpleFitness: -31.1526 Ignored bad PDB record found on line 9131 REMARK FullFitness: -1882.8038 Ignored bad PDB record found on line 9132 REMARK InterFull: -25.0108 Ignored bad PDB record found on line 9133 REMARK IntraFull: -24.0921 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 9185 REMARK Energy: -31.1526 Ignored bad PDB record found on line 9186 REMARK SimpleFitness: -31.1526 Ignored bad PDB record found on line 9187 REMARK FullFitness: -1882.8038 Ignored bad PDB record found on line 9188 REMARK InterFull: -25.0108 Ignored bad PDB record found on line 9189 REMARK IntraFull: -24.0921 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 9241 REMARK Energy: -31.1526 Ignored bad PDB record found on line 9242 REMARK SimpleFitness: -31.1526 Ignored bad PDB record found on line 9243 REMARK FullFitness: -1882.8038 Ignored bad PDB record found on line 9244 REMARK InterFull: -25.0108 Ignored bad PDB record found on line 9245 REMARK IntraFull: -24.0921 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 9297 REMARK Energy: -31.1454 Ignored bad PDB record found on line 9298 REMARK SimpleFitness: -31.1454 Ignored bad PDB record found on line 9299 REMARK FullFitness: -1882.8014 Ignored bad PDB record found on line 9300 REMARK InterFull: -24.9184 Ignored bad PDB record found on line 9301 REMARK IntraFull: -24.1709 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 9353 REMARK Energy: -31.1454 Ignored bad PDB record found on line 9354 REMARK SimpleFitness: -31.1454 Ignored bad PDB record found on line 9355 REMARK FullFitness: -1882.8014 Ignored bad PDB record found on line 9356 REMARK InterFull: -24.9184 Ignored bad PDB record found on line 9357 REMARK IntraFull: -24.1709 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 9409 REMARK Energy: -31.1454 Ignored bad PDB record found on line 9410 REMARK SimpleFitness: -31.1454 Ignored bad PDB record found on line 9411 REMARK FullFitness: -1882.8014 Ignored bad PDB record found on line 9412 REMARK InterFull: -24.9184 Ignored bad PDB record found on line 9413 REMARK IntraFull: -24.1709 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 9465 REMARK Energy: -41.4768 Ignored bad PDB record found on line 9466 REMARK SimpleFitness: -41.4768 Ignored bad PDB record found on line 9467 REMARK FullFitness: -1882.3816 Ignored bad PDB record found on line 9468 REMARK InterFull: -40.9075 Ignored bad PDB record found on line 9469 REMARK IntraFull: -22.4581 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 9521 REMARK Energy: -41.4755 Ignored bad PDB record found on line 9522 REMARK SimpleFitness: -41.4755 Ignored bad PDB record found on line 9523 REMARK FullFitness: -1882.3721 Ignored bad PDB record found on line 9524 REMARK InterFull: -40.9122 Ignored bad PDB record found on line 9525 REMARK IntraFull: -22.4538 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 9577 REMARK Energy: -40.314 Ignored bad PDB record found on line 9578 REMARK SimpleFitness: -40.314 Ignored bad PDB record found on line 9579 REMARK FullFitness: -1879.0454 Ignored bad PDB record found on line 9580 REMARK InterFull: -31.7608 Ignored bad PDB record found on line 9581 REMARK IntraFull: -21.5886 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 9633 REMARK Energy: -40.3206 Ignored bad PDB record found on line 9634 REMARK SimpleFitness: -40.3206 Ignored bad PDB record found on line 9635 REMARK FullFitness: -1878.9927 Ignored bad PDB record found on line 9636 REMARK InterFull: -31.6997 Ignored bad PDB record found on line 9637 REMARK IntraFull: -21.642 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 9689 REMARK Energy: -41.2921 Ignored bad PDB record found on line 9690 REMARK SimpleFitness: -41.2921 Ignored bad PDB record found on line 9691 REMARK FullFitness: -1878.8948 Ignored bad PDB record found on line 9692 REMARK InterFull: -32.7175 Ignored bad PDB record found on line 9693 REMARK IntraFull: -21.4564 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 9745 REMARK Energy: -41.28 Ignored bad PDB record found on line 9746 REMARK SimpleFitness: -41.28 Ignored bad PDB record found on line 9747 REMARK FullFitness: -1878.8823 Ignored bad PDB record found on line 9748 REMARK InterFull: -32.6566 Ignored bad PDB record found on line 9749 REMARK IntraFull: -21.4366 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 9801 REMARK Energy: -41.2488 Ignored bad PDB record found on line 9802 REMARK SimpleFitness: -41.2488 Ignored bad PDB record found on line 9803 REMARK FullFitness: -1878.839 Ignored bad PDB record found on line 9804 REMARK InterFull: -32.6064 Ignored bad PDB record found on line 9805 REMARK IntraFull: -21.4555 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 9857 REMARK Energy: -30.3198 Ignored bad PDB record found on line 9858 REMARK SimpleFitness: -30.3198 Ignored bad PDB record found on line 9859 REMARK FullFitness: -1870.7124 Ignored bad PDB record found on line 9860 REMARK InterFull: -31.8277 Ignored bad PDB record found on line 9861 REMARK IntraFull: -15.5406 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 9913 REMARK Energy: -43.6209 Ignored bad PDB record found on line 9914 REMARK SimpleFitness: -43.6209 Ignored bad PDB record found on line 9915 REMARK FullFitness: -1882.134 Ignored bad PDB record found on line 9916 REMARK InterFull: -43.9594 Ignored bad PDB record found on line 9917 REMARK IntraFull: -16.1317 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 9969 REMARK Energy: -32.1726 Ignored bad PDB record found on line 9970 REMARK SimpleFitness: -32.1726 Ignored bad PDB record found on line 9971 REMARK FullFitness: -1881.8934 Ignored bad PDB record found on line 9972 REMARK InterFull: -20.325 Ignored bad PDB record found on line 9973 REMARK IntraFull: -26.2305 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 10025 REMARK Energy: -32.1964 Ignored bad PDB record found on line 10026 REMARK SimpleFitness: -32.1964 Ignored bad PDB record found on line 10027 REMARK FullFitness: -1881.8191 Ignored bad PDB record found on line 10028 REMARK InterFull: -20.3225 Ignored bad PDB record found on line 10029 REMARK IntraFull: -26.2137 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 10081 REMARK Energy: -32.1964 Ignored bad PDB record found on line 10082 REMARK SimpleFitness: -32.1964 Ignored bad PDB record found on line 10083 REMARK FullFitness: -1881.8191 Ignored bad PDB record found on line 10084 REMARK InterFull: -20.3225 Ignored bad PDB record found on line 10085 REMARK IntraFull: -26.2137 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 10137 REMARK Energy: -32.1964 Ignored bad PDB record found on line 10138 REMARK SimpleFitness: -32.1964 Ignored bad PDB record found on line 10139 REMARK FullFitness: -1881.8191 Ignored bad PDB record found on line 10140 REMARK InterFull: -20.3225 Ignored bad PDB record found on line 10141 REMARK IntraFull: -26.2137 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 10193 REMARK Energy: -32.1957 Ignored bad PDB record found on line 10194 REMARK SimpleFitness: -32.1957 Ignored bad PDB record found on line 10195 REMARK FullFitness: -1881.7651 Ignored bad PDB record found on line 10196 REMARK InterFull: -20.3596 Ignored bad PDB record found on line 10197 REMARK IntraFull: -26.1415 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 10249 REMARK Energy: -32.1957 Ignored bad PDB record found on line 10250 REMARK SimpleFitness: -32.1957 Ignored bad PDB record found on line 10251 REMARK FullFitness: -1881.7651 Ignored bad PDB record found on line 10252 REMARK InterFull: -20.3596 Ignored bad PDB record found on line 10253 REMARK IntraFull: -26.1415 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 10305 REMARK Energy: -32.1957 Ignored bad PDB record found on line 10306 REMARK SimpleFitness: -32.1957 Ignored bad PDB record found on line 10307 REMARK FullFitness: -1881.7651 Ignored bad PDB record found on line 10308 REMARK InterFull: -20.3596 Ignored bad PDB record found on line 10309 REMARK IntraFull: -26.1415 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 10361 REMARK Energy: -32.1957 Ignored bad PDB record found on line 10362 REMARK SimpleFitness: -32.1957 Ignored bad PDB record found on line 10363 REMARK FullFitness: -1881.7651 Ignored bad PDB record found on line 10364 REMARK InterFull: -20.3596 Ignored bad PDB record found on line 10365 REMARK IntraFull: -26.1415 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 10417 REMARK Energy: -37.5113 Ignored bad PDB record found on line 10418 REMARK SimpleFitness: -37.5113 Ignored bad PDB record found on line 10419 REMARK FullFitness: -1881.7084 Ignored bad PDB record found on line 10420 REMARK InterFull: -36.7419 Ignored bad PDB record found on line 10421 REMARK IntraFull: -20.1004 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 10473 REMARK Energy: -37.5088 Ignored bad PDB record found on line 10474 REMARK SimpleFitness: -37.5088 Ignored bad PDB record found on line 10475 REMARK FullFitness: -1881.6686 Ignored bad PDB record found on line 10476 REMARK InterFull: -36.8195 Ignored bad PDB record found on line 10477 REMARK IntraFull: -20.0029 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 10529 REMARK Energy: -37.5088 Ignored bad PDB record found on line 10530 REMARK SimpleFitness: -37.5088 Ignored bad PDB record found on line 10531 REMARK FullFitness: -1881.6686 Ignored bad PDB record found on line 10532 REMARK InterFull: -36.8195 Ignored bad PDB record found on line 10533 REMARK IntraFull: -20.0029 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 10585 REMARK Energy: -37.5088 Ignored bad PDB record found on line 10586 REMARK SimpleFitness: -37.5088 Ignored bad PDB record found on line 10587 REMARK FullFitness: -1881.6686 Ignored bad PDB record found on line 10588 REMARK InterFull: -36.8195 Ignored bad PDB record found on line 10589 REMARK IntraFull: -20.0029 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 10641 REMARK Energy: -37.5089 Ignored bad PDB record found on line 10642 REMARK SimpleFitness: -37.5089 Ignored bad PDB record found on line 10643 REMARK FullFitness: -1881.6644 Ignored bad PDB record found on line 10644 REMARK InterFull: -36.797 Ignored bad PDB record found on line 10645 REMARK IntraFull: -20.0242 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 10697 REMARK Energy: -37.5089 Ignored bad PDB record found on line 10698 REMARK SimpleFitness: -37.5089 Ignored bad PDB record found on line 10699 REMARK FullFitness: -1881.6644 Ignored bad PDB record found on line 10700 REMARK InterFull: -36.797 Ignored bad PDB record found on line 10701 REMARK IntraFull: -20.0242 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 10753 REMARK Energy: -37.5089 Ignored bad PDB record found on line 10754 REMARK SimpleFitness: -37.5089 Ignored bad PDB record found on line 10755 REMARK FullFitness: -1881.6644 Ignored bad PDB record found on line 10756 REMARK InterFull: -36.797 Ignored bad PDB record found on line 10757 REMARK IntraFull: -20.0242 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 10809 REMARK Energy: -37.5089 Ignored bad PDB record found on line 10810 REMARK SimpleFitness: -37.5089 Ignored bad PDB record found on line 10811 REMARK FullFitness: -1881.6644 Ignored bad PDB record found on line 10812 REMARK InterFull: -36.797 Ignored bad PDB record found on line 10813 REMARK IntraFull: -20.0242 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 10865 REMARK Energy: -35.8599 Ignored bad PDB record found on line 10866 REMARK SimpleFitness: -35.8599 Ignored bad PDB record found on line 10867 REMARK FullFitness: -1881.5458 Ignored bad PDB record found on line 10868 REMARK InterFull: -23.1438 Ignored bad PDB record found on line 10869 REMARK IntraFull: -26.362 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 10921 REMARK Energy: -35.8599 Ignored bad PDB record found on line 10922 REMARK SimpleFitness: -35.8599 Ignored bad PDB record found on line 10923 REMARK FullFitness: -1881.5458 Ignored bad PDB record found on line 10924 REMARK InterFull: -23.1438 Ignored bad PDB record found on line 10925 REMARK IntraFull: -26.362 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 10977 REMARK Energy: -35.8695 Ignored bad PDB record found on line 10978 REMARK SimpleFitness: -35.8695 Ignored bad PDB record found on line 10979 REMARK FullFitness: -1881.5344 Ignored bad PDB record found on line 10980 REMARK InterFull: -23.151 Ignored bad PDB record found on line 10981 REMARK IntraFull: -26.3882 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 11033 REMARK Energy: -35.8702 Ignored bad PDB record found on line 11034 REMARK SimpleFitness: -35.8702 Ignored bad PDB record found on line 11035 REMARK FullFitness: -1881.4976 Ignored bad PDB record found on line 11036 REMARK InterFull: -23.2563 Ignored bad PDB record found on line 11037 REMARK IntraFull: -26.3363 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 11089 REMARK Energy: -23.8444 Ignored bad PDB record found on line 11090 REMARK SimpleFitness: -23.8444 Ignored bad PDB record found on line 11091 REMARK FullFitness: -1871.5441 Ignored bad PDB record found on line 11092 REMARK InterFull: -19.9315 Ignored bad PDB record found on line 11093 REMARK IntraFull: -21.0425 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 11145 REMARK Energy: -23.8444 Ignored bad PDB record found on line 11146 REMARK SimpleFitness: -23.8444 Ignored bad PDB record found on line 11147 REMARK FullFitness: -1871.5441 Ignored bad PDB record found on line 11148 REMARK InterFull: -19.9315 Ignored bad PDB record found on line 11149 REMARK IntraFull: -21.0425 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 11201 REMARK Energy: -15.3869 Ignored bad PDB record found on line 11202 REMARK SimpleFitness: -15.3869 Ignored bad PDB record found on line 11203 REMARK FullFitness: -1861.8447 Ignored bad PDB record found on line 11204 REMARK InterFull: -19.7745 Ignored bad PDB record found on line 11205 REMARK IntraFull: -9.90134 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 11257 REMARK Energy: -15.2556 Ignored bad PDB record found on line 11258 REMARK SimpleFitness: -15.2556 Ignored bad PDB record found on line 11259 REMARK FullFitness: -1861.6431 Ignored bad PDB record found on line 11260 REMARK InterFull: -20.1513 Ignored bad PDB record found on line 11261 REMARK IntraFull: -9.22791 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 11313 REMARK Energy: -37.4487 Ignored bad PDB record found on line 11314 REMARK SimpleFitness: -37.4487 Ignored bad PDB record found on line 11315 REMARK FullFitness: -1881.3351 Ignored bad PDB record found on line 11316 REMARK InterFull: -30.1096 Ignored bad PDB record found on line 11317 REMARK IntraFull: -19.1605 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 11369 REMARK Energy: -37.4487 Ignored bad PDB record found on line 11370 REMARK SimpleFitness: -37.4487 Ignored bad PDB record found on line 11371 REMARK FullFitness: -1881.3351 Ignored bad PDB record found on line 11372 REMARK InterFull: -30.1096 Ignored bad PDB record found on line 11373 REMARK IntraFull: -19.1605 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 11425 REMARK Energy: -37.4942 Ignored bad PDB record found on line 11426 REMARK SimpleFitness: -37.4942 Ignored bad PDB record found on line 11427 REMARK FullFitness: -1881.2485 Ignored bad PDB record found on line 11428 REMARK InterFull: -30.258 Ignored bad PDB record found on line 11429 REMARK IntraFull: -19.1404 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 11481 REMARK Energy: -37.4942 Ignored bad PDB record found on line 11482 REMARK SimpleFitness: -37.4942 Ignored bad PDB record found on line 11483 REMARK FullFitness: -1881.2485 Ignored bad PDB record found on line 11484 REMARK InterFull: -30.258 Ignored bad PDB record found on line 11485 REMARK IntraFull: -19.1404 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 11537 REMARK Energy: -37.4859 Ignored bad PDB record found on line 11538 REMARK SimpleFitness: -37.4859 Ignored bad PDB record found on line 11539 REMARK FullFitness: -1881.2308 Ignored bad PDB record found on line 11540 REMARK InterFull: -30.2733 Ignored bad PDB record found on line 11541 REMARK IntraFull: -19.1044 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 11593 REMARK Energy: -37.4859 Ignored bad PDB record found on line 11594 REMARK SimpleFitness: -37.4859 Ignored bad PDB record found on line 11595 REMARK FullFitness: -1881.2308 Ignored bad PDB record found on line 11596 REMARK InterFull: -30.2733 Ignored bad PDB record found on line 11597 REMARK IntraFull: -19.1044 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 11649 REMARK Energy: -37.4859 Ignored bad PDB record found on line 11650 REMARK SimpleFitness: -37.4859 Ignored bad PDB record found on line 11651 REMARK FullFitness: -1881.2308 Ignored bad PDB record found on line 11652 REMARK InterFull: -30.2733 Ignored bad PDB record found on line 11653 REMARK IntraFull: -19.1044 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 11705 REMARK Energy: -37.4859 Ignored bad PDB record found on line 11706 REMARK SimpleFitness: -37.4859 Ignored bad PDB record found on line 11707 REMARK FullFitness: -1881.2308 Ignored bad PDB record found on line 11708 REMARK InterFull: -30.2733 Ignored bad PDB record found on line 11709 REMARK IntraFull: -19.1044 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 11761 REMARK Energy: -36.5872 Ignored bad PDB record found on line 11762 REMARK SimpleFitness: -36.5872 Ignored bad PDB record found on line 11763 REMARK FullFitness: -1881.2758 Ignored bad PDB record found on line 11764 REMARK InterFull: -30.7423 Ignored bad PDB record found on line 11765 REMARK IntraFull: -23.5765 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 11817 REMARK Energy: -34.1687 Ignored bad PDB record found on line 11818 REMARK SimpleFitness: -34.1687 Ignored bad PDB record found on line 11819 REMARK FullFitness: -1878.4666 Ignored bad PDB record found on line 11820 REMARK InterFull: -24.5963 Ignored bad PDB record found on line 11821 REMARK IntraFull: -22.9383 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 11873 REMARK Energy: -34.2845 Ignored bad PDB record found on line 11874 REMARK SimpleFitness: -34.2845 Ignored bad PDB record found on line 11875 REMARK FullFitness: -1878.2236 Ignored bad PDB record found on line 11876 REMARK InterFull: -24.4069 Ignored bad PDB record found on line 11877 REMARK IntraFull: -23.0477 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 11929 REMARK Energy: -43.4771 Ignored bad PDB record found on line 11930 REMARK SimpleFitness: -43.4771 Ignored bad PDB record found on line 11931 REMARK FullFitness: -1880.959 Ignored bad PDB record found on line 11932 REMARK InterFull: -37.8663 Ignored bad PDB record found on line 11933 REMARK IntraFull: -26.3117 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 11985 REMARK Energy: -43.9404 Ignored bad PDB record found on line 11986 REMARK SimpleFitness: -43.9404 Ignored bad PDB record found on line 11987 REMARK FullFitness: -1880.9501 Ignored bad PDB record found on line 11988 REMARK InterFull: -40.901 Ignored bad PDB record found on line 11989 REMARK IntraFull: -25.13 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 12041 REMARK Energy: -43.482 Ignored bad PDB record found on line 12042 REMARK SimpleFitness: -43.482 Ignored bad PDB record found on line 12043 REMARK FullFitness: -1880.9224 Ignored bad PDB record found on line 12044 REMARK InterFull: -37.8386 Ignored bad PDB record found on line 12045 REMARK IntraFull: -26.2707 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 12097 REMARK Energy: -43.4881 Ignored bad PDB record found on line 12098 REMARK SimpleFitness: -43.4881 Ignored bad PDB record found on line 12099 REMARK FullFitness: -1880.888 Ignored bad PDB record found on line 12100 REMARK InterFull: -37.6335 Ignored bad PDB record found on line 12101 REMARK IntraFull: -26.3594 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 12153 REMARK Energy: -43.9853 Ignored bad PDB record found on line 12154 REMARK SimpleFitness: -43.9853 Ignored bad PDB record found on line 12155 REMARK FullFitness: -1880.8448 Ignored bad PDB record found on line 12156 REMARK InterFull: -40.5515 Ignored bad PDB record found on line 12157 REMARK IntraFull: -25.2244 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 12209 REMARK Energy: -43.8642 Ignored bad PDB record found on line 12210 REMARK SimpleFitness: -43.8642 Ignored bad PDB record found on line 12211 REMARK FullFitness: -1880.8119 Ignored bad PDB record found on line 12212 REMARK InterFull: -40.5672 Ignored bad PDB record found on line 12213 REMARK IntraFull: -25.0867 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 12265 REMARK Energy: -40.178 Ignored bad PDB record found on line 12266 REMARK SimpleFitness: -40.178 Ignored bad PDB record found on line 12267 REMARK FullFitness: -1875.543 Ignored bad PDB record found on line 12268 REMARK InterFull: -32.2972 Ignored bad PDB record found on line 12269 REMARK IntraFull: -24.1599 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 12321 REMARK Energy: -39.9844 Ignored bad PDB record found on line 12322 REMARK SimpleFitness: -39.9844 Ignored bad PDB record found on line 12323 REMARK FullFitness: -1875.3936 Ignored bad PDB record found on line 12324 REMARK InterFull: -33.054 Ignored bad PDB record found on line 12325 REMARK IntraFull: -24.3925 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 12377 REMARK Energy: -42.1325 Ignored bad PDB record found on line 12378 REMARK SimpleFitness: -42.1325 Ignored bad PDB record found on line 12379 REMARK FullFitness: -1880.8716 Ignored bad PDB record found on line 12380 REMARK InterFull: -36.7395 Ignored bad PDB record found on line 12381 REMARK IntraFull: -26.3949 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 12433 REMARK Energy: -40.1052 Ignored bad PDB record found on line 12434 REMARK SimpleFitness: -40.1052 Ignored bad PDB record found on line 12435 REMARK FullFitness: -1879.6609 Ignored bad PDB record found on line 12436 REMARK InterFull: -30.3307 Ignored bad PDB record found on line 12437 REMARK IntraFull: -28.421 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 12489 REMARK Energy: -40.7985 Ignored bad PDB record found on line 12490 REMARK SimpleFitness: -40.7985 Ignored bad PDB record found on line 12491 REMARK FullFitness: -1879.4844 Ignored bad PDB record found on line 12492 REMARK InterFull: -37.6723 Ignored bad PDB record found on line 12493 REMARK IntraFull: -24.407 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 12545 REMARK Energy: -39.2005 Ignored bad PDB record found on line 12546 REMARK SimpleFitness: -39.2005 Ignored bad PDB record found on line 12547 REMARK FullFitness: -1876.8129 Ignored bad PDB record found on line 12548 REMARK InterFull: -35.1411 Ignored bad PDB record found on line 12549 REMARK IntraFull: -25.0507 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 12601 REMARK Energy: -39.4009 Ignored bad PDB record found on line 12602 REMARK SimpleFitness: -39.4009 Ignored bad PDB record found on line 12603 REMARK FullFitness: -1876.7648 Ignored bad PDB record found on line 12604 REMARK InterFull: -35.6154 Ignored bad PDB record found on line 12605 REMARK IntraFull: -24.7573 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 12657 REMARK Energy: -34.1416 Ignored bad PDB record found on line 12658 REMARK SimpleFitness: -34.1416 Ignored bad PDB record found on line 12659 REMARK FullFitness: -1874.4696 Ignored bad PDB record found on line 12660 REMARK InterFull: -34.3061 Ignored bad PDB record found on line 12661 REMARK IntraFull: -21.3417 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 12713 REMARK Energy: -33.8802 Ignored bad PDB record found on line 12714 REMARK SimpleFitness: -33.8802 Ignored bad PDB record found on line 12715 REMARK FullFitness: -1874.2828 Ignored bad PDB record found on line 12716 REMARK InterFull: -34.1938 Ignored bad PDB record found on line 12717 REMARK IntraFull: -21.3078 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 12769 REMARK Energy: -35.8273 Ignored bad PDB record found on line 12770 REMARK SimpleFitness: -35.8273 Ignored bad PDB record found on line 12771 REMARK FullFitness: -1872.481 Ignored bad PDB record found on line 12772 REMARK InterFull: -31.1933 Ignored bad PDB record found on line 12773 REMARK IntraFull: -22.0368 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 12825 REMARK Energy: -40.937 Ignored bad PDB record found on line 12826 REMARK SimpleFitness: -40.937 Ignored bad PDB record found on line 12827 REMARK FullFitness: -1880.7983 Ignored bad PDB record found on line 12828 REMARK InterFull: -43.8385 Ignored bad PDB record found on line 12829 REMARK IntraFull: -19.4397 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 12881 REMARK Energy: -41.2083 Ignored bad PDB record found on line 12882 REMARK SimpleFitness: -41.2083 Ignored bad PDB record found on line 12883 REMARK FullFitness: -1880.5839 Ignored bad PDB record found on line 12884 REMARK InterFull: -32.8806 Ignored bad PDB record found on line 12885 REMARK IntraFull: -20.9834 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 12937 REMARK Energy: -37.1055 Ignored bad PDB record found on line 12938 REMARK SimpleFitness: -37.1055 Ignored bad PDB record found on line 12939 REMARK FullFitness: -1873.6051 Ignored bad PDB record found on line 12940 REMARK InterFull: -38.2592 Ignored bad PDB record found on line 12941 REMARK IntraFull: -15.9119 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 12993 REMARK Energy: -43.5537 Ignored bad PDB record found on line 12994 REMARK SimpleFitness: -43.5537 Ignored bad PDB record found on line 12995 REMARK FullFitness: -1880.0659 Ignored bad PDB record found on line 12996 REMARK InterFull: -40.8922 Ignored bad PDB record found on line 12997 REMARK IntraFull: -21.5157 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 13049 REMARK Energy: -38.9253 Ignored bad PDB record found on line 13050 REMARK SimpleFitness: -38.9253 Ignored bad PDB record found on line 13051 REMARK FullFitness: -1874.0651 Ignored bad PDB record found on line 13052 REMARK InterFull: -39.4474 Ignored bad PDB record found on line 13053 REMARK IntraFull: -17.5978 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 13105 REMARK Energy: -37.4593 Ignored bad PDB record found on line 13106 REMARK SimpleFitness: -37.4593 Ignored bad PDB record found on line 13107 REMARK FullFitness: -1879.5918 Ignored bad PDB record found on line 13108 REMARK InterFull: -30.7032 Ignored bad PDB record found on line 13109 REMARK IntraFull: -22.0555 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 13161 REMARK Energy: -35.1189 Ignored bad PDB record found on line 13162 REMARK SimpleFitness: -35.1189 Ignored bad PDB record found on line 13163 REMARK FullFitness: -1877.8228 Ignored bad PDB record found on line 13164 REMARK InterFull: -27.4148 Ignored bad PDB record found on line 13165 REMARK IntraFull: -22.8449 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 13217 REMARK Energy: -34.4489 Ignored bad PDB record found on line 13218 REMARK SimpleFitness: -34.4489 Ignored bad PDB record found on line 13219 REMARK FullFitness: -1879.4086 Ignored bad PDB record found on line 13220 REMARK InterFull: -27.8608 Ignored bad PDB record found on line 13221 REMARK IntraFull: -22.3286 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 13273 REMARK Energy: -41.7109 Ignored bad PDB record found on line 13274 REMARK SimpleFitness: -41.7109 Ignored bad PDB record found on line 13275 REMARK FullFitness: -1878.7877 Ignored bad PDB record found on line 13276 REMARK InterFull: -34.0424 Ignored bad PDB record found on line 13277 REMARK IntraFull: -20.8084 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 13329 REMARK Energy: -41.9971 Ignored bad PDB record found on line 13330 REMARK SimpleFitness: -41.9971 Ignored bad PDB record found on line 13331 REMARK FullFitness: -1877.8947 Ignored bad PDB record found on line 13332 REMARK InterFull: -30.3043 Ignored bad PDB record found on line 13333 REMARK IntraFull: -24.3233 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 13385 REMARK Energy: -35.4205 Ignored bad PDB record found on line 13386 REMARK SimpleFitness: -35.4205 Ignored bad PDB record found on line 13387 REMARK FullFitness: -1877.7095 Ignored bad PDB record found on line 13388 REMARK InterFull: -36.3418 Ignored bad PDB record found on line 13389 REMARK IntraFull: -18.2306 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 13441 REMARK Energy: -34.0705 Ignored bad PDB record found on line 13442 REMARK SimpleFitness: -34.0705 Ignored bad PDB record found on line 13443 REMARK FullFitness: -1877.4734 Ignored bad PDB record found on line 13444 REMARK InterFull: -36.1243 Ignored bad PDB record found on line 13445 REMARK IntraFull: -17.4842 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 13497 REMARK Energy: -38.0272 Ignored bad PDB record found on line 13498 REMARK SimpleFitness: -38.0272 Ignored bad PDB record found on line 13499 REMARK FullFitness: -1877.0101 Ignored bad PDB record found on line 13500 REMARK InterFull: -30.8366 Ignored bad PDB record found on line 13501 REMARK IntraFull: -21.0215 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 13553 REMARK Energy: -37.7177 Ignored bad PDB record found on line 13554 REMARK SimpleFitness: -37.7177 Ignored bad PDB record found on line 13555 REMARK FullFitness: -1876.8678 Ignored bad PDB record found on line 13556 REMARK InterFull: -31.4009 Ignored bad PDB record found on line 13557 REMARK IntraFull: -21.5368 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 13609 REMARK Energy: -34.8061 Ignored bad PDB record found on line 13610 REMARK SimpleFitness: -34.8061 Ignored bad PDB record found on line 13611 REMARK FullFitness: -1876.6477 Ignored bad PDB record found on line 13612 REMARK InterFull: -32.5429 Ignored bad PDB record found on line 13613 REMARK IntraFull: -20.8037 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 13665 REMARK Energy: -36.6879 Ignored bad PDB record found on line 13666 REMARK SimpleFitness: -36.6879 Ignored bad PDB record found on line 13667 REMARK FullFitness: -1875.9742 Ignored bad PDB record found on line 13668 REMARK InterFull: -34.0504 Ignored bad PDB record found on line 13669 REMARK IntraFull: -21.8969 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 13721 REMARK Energy: -37.8982 Ignored bad PDB record found on line 13722 REMARK SimpleFitness: -37.8982 Ignored bad PDB record found on line 13723 REMARK FullFitness: -1875.796 Ignored bad PDB record found on line 13724 REMARK InterFull: -35.5243 Ignored bad PDB record found on line 13725 REMARK IntraFull: -17.8007 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 13777 REMARK Energy: -39.1886 Ignored bad PDB record found on line 13778 REMARK SimpleFitness: -39.1886 Ignored bad PDB record found on line 13779 REMARK FullFitness: -1875.6692 Ignored bad PDB record found on line 13780 REMARK InterFull: -31.3261 Ignored bad PDB record found on line 13781 REMARK IntraFull: -25.0343 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 13833 REMARK Energy: -36.3635 Ignored bad PDB record found on line 13834 REMARK SimpleFitness: -36.3635 Ignored bad PDB record found on line 13835 REMARK FullFitness: -1874.8938 Ignored bad PDB record found on line 13836 REMARK InterFull: -36.936 Ignored bad PDB record found on line 13837 REMARK IntraFull: -17.8749 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 13889 REMARK Energy: -35.5235 Ignored bad PDB record found on line 13890 REMARK SimpleFitness: -35.5235 Ignored bad PDB record found on line 13891 REMARK FullFitness: -1874.6633 Ignored bad PDB record found on line 13892 REMARK InterFull: -29.7253 Ignored bad PDB record found on line 13893 REMARK IntraFull: -21.8999 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 13945 REMARK Energy: -34.555 Ignored bad PDB record found on line 13946 REMARK SimpleFitness: -34.555 Ignored bad PDB record found on line 13947 REMARK FullFitness: -1872.992 Ignored bad PDB record found on line 13948 REMARK InterFull: -31.3996 Ignored bad PDB record found on line 13949 REMARK IntraFull: -18.0613 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 14001 REMARK Energy: -34.4974 Ignored bad PDB record found on line 14002 REMARK SimpleFitness: -34.4974 Ignored bad PDB record found on line 14003 REMARK FullFitness: -1871.5823 Ignored bad PDB record found on line 14004 REMARK InterFull: -28.837 Ignored bad PDB record found on line 14005 REMARK IntraFull: -17.7553 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 14057 REMARK Energy: -34.3939 Ignored bad PDB record found on line 14058 REMARK SimpleFitness: -34.3939 Ignored bad PDB record found on line 14059 REMARK FullFitness: -1871.5259 Ignored bad PDB record found on line 14060 REMARK InterFull: -28.9272 Ignored bad PDB record found on line 14061 REMARK IntraFull: -17.5334 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 14113 REMARK Energy: -30.2184 Ignored bad PDB record found on line 14114 REMARK SimpleFitness: -30.2184 Ignored bad PDB record found on line 14115 REMARK FullFitness: -1869.114 Ignored bad PDB record found on line 14116 REMARK InterFull: -38.7852 Ignored bad PDB record found on line 14117 REMARK IntraFull: -11.2806 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 14169 REMARK Energy: -17.0298 Ignored bad PDB record found on line 14170 REMARK SimpleFitness: -17.0298 Ignored bad PDB record found on line 14171 REMARK FullFitness: -1867.6995 Ignored bad PDB record found on line 14172 REMARK InterFull: -15.5643 Ignored bad PDB record found on line 14173 REMARK IntraFull: -17.9901 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 14225 REMARK Energy: -24.3948 Ignored bad PDB record found on line 14226 REMARK SimpleFitness: -24.3948 Ignored bad PDB record found on line 14227 REMARK FullFitness: -1867.455 Ignored bad PDB record found on line 14228 REMARK InterFull: -36.921 Ignored bad PDB record found on line 14229 REMARK IntraFull: -8.04902 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted Ignored bad PDB record found on line 14281 REMARK Energy: 2.62636 Ignored bad PDB record found on line 14282 REMARK SimpleFitness: 2.62636 Ignored bad PDB record found on line 14283 REMARK FullFitness: -1837.4614 Ignored bad PDB record found on line 14284 REMARK InterFull: -18.2886 Ignored bad PDB record found on line 14285 REMARK IntraFull: 3.22925 14 messages similar to the above omitted Duplicate atom serial number found: 7541 Duplicate atom serial number found: 7542 Duplicate atom serial number found: 7543 Duplicate atom serial number found: 7544 Duplicate atom serial number found: 7545 31 messages similar to the above omitted > lighting full ===== Log before crash end ===== Log: UCSF ChimeraX version: 1.3 (2021-12-08) © 2016-2021 Regents of the University of California. All rights reserved. > open "C:\\\MW\\\add- > on\\\\_work\\\SCHMA_ALDH_312er_homotetramer_from-2x-homotrimer_Deepmind_v3_hide > surfaces.cxs" Log from Mon Jun 6 16:32:15 2022UCSF ChimeraX version: 1.3 (2021-12-08) © 2016-2021 Regents of the University of California. All rights reserved. > open C:\\\MW\\\add- > on\\\\_work\\\SCHMA_ALDH_312er_homotetramer_from-2x-homotrimer_Deepmind_v2.cxs Log from Mon Jun 6 15:11:17 2022UCSF ChimeraX version: 1.3 (2021-12-08) © 2016-2021 Regents of the University of California. All rights reserved. How to cite UCSF ChimeraX > open C:\\\MW\\\add- > on\\\\_work\\\SCHMA_ALDH_312er_homotrimer_Deepmind_selected_prediction.pdb Chain information for SCHMA_ALDH_312er_homotrimer_Deepmind_selected_prediction.pdb #1 --- Chain | Description A B C | No description available > color bychain > lighting full > open C:/MW/add- > on/_work/SCHMA_ALDH_312er_homotrimer_Deepmind_selected_prediction.pdb Chain information for SCHMA_ALDH_312er_homotrimer_Deepmind_selected_prediction.pdb #2 --- Chain | Description A B C | No description available > matchmaker #2 to #1 Parameters --- Chain pairing | bb Alignment algorithm | Needleman-Wunsch Similarity matrix | BLOSUM-62 SS fraction | 0.3 Gap open (HH/SS/other) | 18/18/6 Gap extend | 1 SS matrix | | | H | S | O ---|---|---|--- H | 6 | -9 | -6 S | | 6 | -6 O | | | 4 Iteration cutoff | 2 Matchmaker SCHMA_ALDH_312er_homotrimer_Deepmind_selected_prediction.pdb, chain B (#1) with SCHMA_ALDH_312er_homotrimer_Deepmind_selected_prediction.pdb, chain B (#2), sequence alignment score = 2558.5 RMSD between 491 pruned atom pairs is 0.000 angstroms; (across all 491 pairs: 0.000) > matchmaker #2 to #1/C Parameters --- Chain pairing | bb Alignment algorithm | Needleman-Wunsch Similarity matrix | BLOSUM-62 SS fraction | 0.3 Gap open (HH/SS/other) | 18/18/6 Gap extend | 1 SS matrix | | | H | S | O ---|---|---|--- H | 6 | -9 | -6 S | | 6 | -6 O | | | 4 Iteration cutoff | 2 Matchmaker SCHMA_ALDH_312er_homotrimer_Deepmind_selected_prediction.pdb, chain C (#1) with SCHMA_ALDH_312er_homotrimer_Deepmind_selected_prediction.pdb, chain B (#2), sequence alignment score = 2558.5 RMSD between 491 pruned atom pairs is 0.136 angstroms; (across all 491 pairs: 0.136) > save C:/MW/add- > on/_work/SCHMA_ALDH_312er_homotetramer_from-2x-homotrimer_Deepmind.cxs > hide #1 models > show #1 models > hide #1 models > show #1 models > hide #1 models > select #2/C 7540 atoms, 7616 bonds, 491 residues, 1 model selected > delete atoms sel > delete bonds sel > select #2/B 7540 atoms, 7616 bonds, 491 residues, 1 model selected > delete atoms sel > delete bonds sel > show #1 models > save C:/MW/add- > on/_work/SCHMA_ALDH_312er_homotetramer_from-2x-homotrimer_Deepmind_v2.cxs ——— End of log from Mon Jun 6 15:11:17 2022 ——— opened ChimeraX session > color #1/A dark grey > color #1/C tan > color #1/B slate blue > color #2/A dark sea green > lighting full > show surfaces > color #1/A dark grey > color #1/C tan > color #1/B slate blue > lighting full > show surfaces > color #1/A dark grey > color #1/C tan > color #2/A dark sea green > save C:/MW/add- > on/_work/SCHMA_ALDH_312er_homotetramer_from-2x-homotrimer_Deepmind_v3.cxs > select #2/A 7540 atoms, 7616 bonds, 491 residues, 1 model selected > hide sel surfaces > select #1/B 7540 atoms, 7616 bonds, 491 residues, 1 model selected > hide sel surfaces > select #1/C 7540 atoms, 7616 bonds, 491 residues, 1 model selected > hide sel surfaces > select clear > save "C:/MW/add- > on/_work/SCHMA_ALDH_312er_homotetramer_from-2x-homotrimer_Deepmind_v3_hide > surfaces.cxs" ——— End of log from Mon Jun 6 16:32:15 2022 ——— opened ChimeraX session OpenGL version: 3.3.14831 Core Profile Forward-Compatible Context 21.5.2 27.20.20903.8001 OpenGL renderer: AMD Radeon R9 200 Series OpenGL vendor: ATI Technologies Inc. Manufacturer: Gigabyte Technology Co., Ltd. Model: H67MA-UD2H OS: Microsoft Windows 10 Pro (Build 19044) Memory: 17,162,481,664 MaxProcessMemory: 137,438,953,344 CPU: 4 Intel(R) Core(TM) i5-2500K CPU @ 3.30GHz OSLanguage: de-DE Locale: ('de_DE', 'cp1252') PyQt5 5.15.2, Qt 5.15.2 Installed Packages: alabaster: 0.7.12 appdirs: 1.4.4 Babel: 2.9.1 backcall: 0.2.0 blockdiag: 2.0.1 certifi: 2021.10.8 cftime: 1.5.1.1 charset-normalizer: 2.0.9 ChimeraX-AddCharge: 1.2.2 ChimeraX-AddH: 2.1.11 ChimeraX-AlignmentAlgorithms: 2.0 ChimeraX-AlignmentHdrs: 3.2 ChimeraX-AlignmentMatrices: 2.0 ChimeraX-Alignments: 2.2.3 ChimeraX-AlphaFold: 1.0 ChimeraX-AltlocExplorer: 1.0.1 ChimeraX-AmberInfo: 1.0 ChimeraX-Arrays: 1.0 ChimeraX-Atomic: 1.31 ChimeraX-AtomicLibrary: 4.2 ChimeraX-AtomSearch: 2.0 ChimeraX-AtomSearchLibrary: 1.0 ChimeraX-AxesPlanes: 2.0 ChimeraX-BasicActions: 1.1 ChimeraX-BILD: 1.0 ChimeraX-BlastProtein: 2.0 ChimeraX-BondRot: 2.0 ChimeraX-BugReporter: 1.0 ChimeraX-BuildStructure: 2.6.1 ChimeraX-Bumps: 1.0 ChimeraX-BundleBuilder: 1.1 ChimeraX-ButtonPanel: 1.0 ChimeraX-CageBuilder: 1.0 ChimeraX-CellPack: 1.0 ChimeraX-Centroids: 1.2 ChimeraX-ChemGroup: 2.0 ChimeraX-Clashes: 2.2.2 ChimeraX-ColorActions: 1.0 ChimeraX-ColorGlobe: 1.0 ChimeraX-ColorKey: 1.5 ChimeraX-CommandLine: 1.1.5 ChimeraX-ConnectStructure: 2.0 ChimeraX-Contacts: 1.0 ChimeraX-Core: 1.3 ChimeraX-CoreFormats: 1.1 ChimeraX-coulombic: 1.3.2 ChimeraX-Crosslinks: 1.0 ChimeraX-Crystal: 1.0 ChimeraX-CrystalContacts: 1.0 ChimeraX-DataFormats: 1.2.2 ChimeraX-Dicom: 1.0 ChimeraX-DistMonitor: 1.1.5 ChimeraX-DistUI: 1.0 ChimeraX-Dssp: 2.0 ChimeraX-EMDB-SFF: 1.0 ChimeraX-ExperimentalCommands: 1.0 ChimeraX-FileHistory: 1.0 ChimeraX-FunctionKey: 1.0 ChimeraX-Geometry: 1.1 ChimeraX-gltf: 1.0 ChimeraX-Graphics: 1.1 ChimeraX-Hbonds: 2.1.2 ChimeraX-Help: 1.2 ChimeraX-HKCage: 1.3 ChimeraX-IHM: 1.1 ChimeraX-ImageFormats: 1.2 ChimeraX-IMOD: 1.0 ChimeraX-IO: 1.0.1 ChimeraX-ItemsInspection: 1.0 ChimeraX-Label: 1.1 ChimeraX-ListInfo: 1.1.1 ChimeraX-Log: 1.1.4 ChimeraX-LookingGlass: 1.1 ChimeraX-Maestro: 1.8.1 ChimeraX-Map: 1.1 ChimeraX-MapData: 2.0 ChimeraX-MapEraser: 1.0 ChimeraX-MapFilter: 2.0 ChimeraX-MapFit: 2.0 ChimeraX-MapSeries: 2.1 ChimeraX-Markers: 1.0 ChimeraX-Mask: 1.0 ChimeraX-MatchMaker: 2.0.4 ChimeraX-MDcrds: 2.6 ChimeraX-MedicalToolbar: 1.0.1 ChimeraX-Meeting: 1.0 ChimeraX-MLP: 1.1 ChimeraX-mmCIF: 2.4 ChimeraX-MMTF: 2.1 ChimeraX-Modeller: 1.2.6 ChimeraX-ModelPanel: 1.2.1 ChimeraX-ModelSeries: 1.0 ChimeraX-Mol2: 2.0 ChimeraX-Morph: 1.0 ChimeraX-MouseModes: 1.1 ChimeraX-Movie: 1.0 ChimeraX-Neuron: 1.0 ChimeraX-Nucleotides: 2.0.2 ChimeraX-OpenCommand: 1.7 ChimeraX-PDB: 2.6.5 ChimeraX-PDBBio: 1.0 ChimeraX-PDBLibrary: 1.0.2 ChimeraX-PDBMatrices: 1.0 ChimeraX-PickBlobs: 1.0 ChimeraX-Positions: 1.0 ChimeraX-PresetMgr: 1.0.1 ChimeraX-PubChem: 2.1 ChimeraX-ReadPbonds: 1.0.1 ChimeraX-Registration: 1.1 ChimeraX-RemoteControl: 1.0 ChimeraX-ResidueFit: 1.0 ChimeraX-RestServer: 1.1 ChimeraX-RNALayout: 1.0 ChimeraX-RotamerLibMgr: 2.0.1 ChimeraX-RotamerLibsDunbrack: 2.0 ChimeraX-RotamerLibsDynameomics: 2.0 ChimeraX-RotamerLibsRichardson: 2.0 ChimeraX-SaveCommand: 1.5 ChimeraX-SchemeMgr: 1.0 ChimeraX-SDF: 2.0 ChimeraX-Segger: 1.0 ChimeraX-Segment: 1.0 ChimeraX-SelInspector: 1.0 ChimeraX-SeqView: 2.4.6 ChimeraX-Shape: 1.0.1 ChimeraX-Shell: 1.0 ChimeraX-Shortcuts: 1.1 ChimeraX-ShowAttr: 1.0 ChimeraX-ShowSequences: 1.0 ChimeraX-SideView: 1.0 ChimeraX-Smiles: 2.1 ChimeraX-SmoothLines: 1.0 ChimeraX-SpaceNavigator: 1.0 ChimeraX-StdCommands: 1.6.1 ChimeraX-STL: 1.0 ChimeraX-Storm: 1.0 ChimeraX-Struts: 1.0 ChimeraX-Surface: 1.0 ChimeraX-SwapAA: 2.0 ChimeraX-SwapRes: 2.1 ChimeraX-TapeMeasure: 1.0 ChimeraX-Test: 1.0 ChimeraX-Toolbar: 1.1 ChimeraX-ToolshedUtils: 1.2 ChimeraX-Tug: 1.0 ChimeraX-UI: 1.13.7 ChimeraX-uniprot: 2.2 ChimeraX-UnitCell: 1.0 ChimeraX-ViewDockX: 1.0.1 ChimeraX-VIPERdb: 1.0 ChimeraX-Vive: 1.1 ChimeraX-VolumeMenu: 1.0 ChimeraX-VTK: 1.0 ChimeraX-WavefrontOBJ: 1.0 ChimeraX-WebCam: 1.0 ChimeraX-WebServices: 1.0 ChimeraX-Zone: 1.0 colorama: 0.4.4 comtypes: 1.1.10 cxservices: 1.1 cycler: 0.11.0 Cython: 0.29.24 decorator: 5.1.0 docutils: 0.17.1 filelock: 3.0.12 funcparserlib: 0.3.6 grako: 3.16.5 h5py: 3.6.0 html2text: 2020.1.16 idna: 3.3 ihm: 0.21 imagecodecs: 2021.4.28 imagesize: 1.3.0 ipykernel: 5.5.5 ipython: 7.23.1 ipython-genutils: 0.2.0 jedi: 0.18.0 Jinja2: 3.0.1 jupyter-client: 6.1.12 jupyter-core: 4.9.1 kiwisolver: 1.3.2 lxml: 4.6.3 lz4: 3.1.3 MarkupSafe: 2.0.1 matplotlib: 3.4.3 matplotlib-inline: 0.1.3 msgpack: 1.0.2 netCDF4: 1.5.7 networkx: 2.6.3 numexpr: 2.8.0 numpy: 1.21.2 openvr: 1.16.801 packaging: 21.3 ParmEd: 3.2.0 parso: 0.8.3 pickleshare: 0.7.5 Pillow: 8.3.2 pip: 21.2.4 pkginfo: 1.7.1 prompt-toolkit: 3.0.23 psutil: 5.8.0 pycollada: 0.7.1 pydicom: 2.1.2 Pygments: 2.10.0 PyOpenGL: 3.1.5 PyOpenGL-accelerate: 3.1.5 pyparsing: 3.0.6 PyQt5-commercial: 5.15.2 PyQt5-sip: 12.8.1 PyQtWebEngine-commercial: 5.15.2 python-dateutil: 2.8.2 pytz: 2021.3 pywin32: 228 pyzmq: 22.3.0 qtconsole: 5.1.1 QtPy: 1.11.3 RandomWords: 0.3.0 requests: 2.26.0 scipy: 1.7.1 setuptools: 57.5.0 sfftk-rw: 0.7.1 six: 1.16.0 snowballstemmer: 2.2.0 sortedcontainers: 2.4.0 Sphinx: 4.2.0 sphinx-autodoc-typehints: 1.12.0 sphinxcontrib-applehelp: 1.0.2 sphinxcontrib-blockdiag: 2.0.0 sphinxcontrib-devhelp: 1.0.2 sphinxcontrib-htmlhelp: 2.0.0 sphinxcontrib-jsmath: 1.0.1 sphinxcontrib-qthelp: 1.0.3 sphinxcontrib-serializinghtml: 1.1.5 suds-jurko: 0.6 tables: 3.6.1 tifffile: 2021.4.8 tinyarray: 1.2.3 tornado: 6.1 traitlets: 5.1.1 urllib3: 1.26.7 wcwidth: 0.2.5 webcolors: 1.11.1 wheel: 0.37.0 wheel-filename: 1.3.0 WMI: 1.5.1
Change History (15)
comment:1 by , 3 years ago
Cc: | added |
---|---|
Component: | Unassigned → Platform |
Description: | modified (diff) |
Owner: | set to |
Platform: | → all |
Project: | → ChimeraX |
Status: | new → accepted |
Summary: | ChimeraX bug report submission → Crash using File→Open on Windows and/or in return statement |
comment:2 by , 3 years ago
Resolution: | → can't reproduce |
---|---|
Status: | accepted → closed |
follow-up: 3 comment:3 by , 3 years ago
Hi, thanks for your quick reply. Unfortunately, the latest ChimeraX-rc4 candidate does not fix the problem. Best regards, Michael. Am 06.06.2022 20:30 schrieb ChimeraX:
follow-up: 4 comment:4 by , 3 years ago
Maybe one more remark: I think it might have something to do with AMD graphics driver. I worked with the same files earlier using an NVIDIA ASUS RTX 2080 GPU without issues. So, the crash appears to occur selectively (?) on AMD R9 290X and Intel iGPUs. -Michael. Am 06.06.2022 20:30 schrieb ChimeraX:
follow-up: 5 comment:5 by , 3 years ago
Thanks for the info. It would be helpful if you reported the crash with the release candidate. It may give us better clues than when you reported it with ChimeraX 1.3. It is common that unstable graphics drivers lead to ChimeraX crashes.
comment:6 by , 3 years ago
It seems like you're reporting two different types of crashes. One is when you're trying to open the file in ChimeraX. The other is when you change your graphics card's output quality to "full". Is that correct? We would expect the 1.4 release candidate to fix the first crash, but not the second one.
follow-up: 7 comment:7 by , 3 years ago
Hi, when talking about 'changing the graphics card's output quality' I mean changing it from within ChimeraX by selecting the 'full' visualization mode. I figured that this change is actually the main cause of the crash. I can load an manipulate the files of discussion but as soon as I switch ChimeraX to publication quality mode, it crashes as reported. In the previous crashes (where it seemed to be a different cause) I used files where the full mode was already activated in a ChimeraX session file which I loaded and then used to further work with (by loading the 'problematic' SwissDock results files). Best regards, Michael. Am 07.06.2022 00:43 schrieb ChimeraX:
comment:8 by , 3 years ago
Hi Michael,
Since there is nothing in ChimeraX documented as "full quality" I was guessing what you meant there. Yes, going to a publication preset (particularly the silhouette one) will exercise additional capabilities of your graphics card, and if the driver is buggy then it could cause a crash. You should check the AMD website and see if there are updated drivers available for your card.
--Eric
follow-up: 9 comment:9 by , 3 years ago
Hi Eric, I am talking about setting the lighting to 'full'. Pressing that button in the ChimeraX GUI causes ChimeraX to crash with my SwissDoc result file archive. Regarding the graphics driver, I am using the latest AMD driver set available for my system. Intel iGPUs appear to have the same issue on an ASUS ZenBook UX305. Maybe I could upload the file set I am having problems with to some cloud storage such that you can try to reproduce the problem? Best regards, Michael. Am 07.06.2022 18:32 schrieb ChimeraX:
follow-up: 10 comment:10 by , 3 years ago
Under the following URL you will find a .zip archive containing the crash-causing file set as supplied by the SwissDock docking server plus a text file in which you find detailed instructions on how to reproduce the error: https://drive.google.com/drive/folders/1AOj6PqSlti9PcTbvZSLN0-sQT-UoMwQJ?usp=sharing It is all together less than 2 MB in size. Best regards, Michael. Am 07.06.2022 18:32 schrieb ChimeraX:
comment:11 by , 3 years ago
Hi Michael,
I can use full lighting on your system without a crash. It is slow to compute the shadows initially and laggy in responsiveness to rotations, but it does not crash. Normal full lighting uses 64 shadow directions. Try this command "lighting full multishadow 16". Does that crash?
--Eric
follow-up: 12 comment:12 by , 3 years ago
This is almost surely a crash from an unstable graphics driver. Unfortunately the newest graphics driver is not always the most stable. AMD and Nvidia sometimes introduce new bugs. It is sometimes necessary to install an older driver if the problem is severe enough that it is worth your trouble. ChimeraX sees your graphics as "AMD Radeon R9 200 Series" various cards released in 2013 and 2014. This graphics is quite old and it is not too surprising when AMD and Nvidia introduce bugs for such old cards that they likely no longer test against.
follow-up: 13 comment:13 by , 3 years ago
Hi Eric, I tried the command you suggested and under these conditions ChimeraX does NOT crash - thank you very much. When tying "lighting full multishadow 32", however, it already crashes again. Best regards, Michael. Am 08.06.2022 02:53 schrieb ChimeraX:
follow-up: 14 comment:14 by , 3 years ago
Hi, I have to use AMD driver 21.5.2 because, strangely, only the AMD GPU driver-setup autodetection client allows for the GPU driver set installation on this recently installed Windows 10 Pro (ver. 21H2, build 19044.1706) x64 machine (it is an i5-2500K quadcore CPU with 16 GB of RAM and an AMD R9 290X GPU (MSI Lighning model), so not the most recent stuff on the market (but the GPU still outperforms even recent consumer NVIDA cards of the latest models in double precision calculations)). Could you maybe suggest a driver you know to work properly with ChimeraX in this hardware setting? Best regards, Michael. Am 08.06.2022 03:06 schrieb ChimeraX:
follow-up: 15 comment:15 by , 3 years ago
We only have a few of the hundreds of graphics cards to test with in our lab, so we don't know what drivers work with which cards except when we get bug reports. Most drivers, I'd say 95% are fine, so it is relatively rare to encounter driver crashes.
Hi Michael,
--Eric